The SmaRT DIN-9H4R-2DI Base Unit is designed for standard DIN rail mounting in industrial control systems. It features spread spectrum technology, four Form A relay contact outputs, two discrete inputs, CAN J1939 connectivity, and diagnostic LED indicators. The unit is compact and can be mounted horizontally or vertically.

Features
  • Spread Spectrum Technology
  • 4 Form A Relay Contact Outputs
  • 2 Discrete Inputs
  • CAN J1939 Connectivity
  • DIN Enclosure with Screw Terminal Connections
  • Diagnostic LED Indicators
  • Compact Design

Specifications
  • Power: 18–32VDC (24V option) or 85–220VAC (120VAC option), Operating Power 5W max.
  • Enclosure: Dimensions 1.72W x 3.23H x 3.91D inches, Weight 4 oz., Durable UL94V-0 rated ABS plastic
  • Environment: Operating Temp -25°C to 60°C, Storage Temp -40°C to 85°C, Humidity 0 to 95% non-condensing
  • Radio: Frequency 906-924MHz, RF Power 10mW, License Free, Modulation DSSS, External Antenna (RP-SMA)
  • Outputs: Four Relays Form A, 2A max @ 250VAC/30VDC inductive load, 5A max resistive load, Total 10A max.
  • Inputs: Two 2-terminal isolated, 18-32 VDC (24V option), 85-220VAC (120 option)

Terminal Wiring
The unit includes various terminal connections for inputs, outputs, and communication interfaces. Key terminals include K1-K4 for relay connections, TX/RX for RS-232 communication, and CANL/CANH for CAN bus connectivity.

Options
Two model options are available: DIN-9H4R-2DI-EXT-24V for 18-32VDC input and DIN-9H4R-2DI-EXT-120 for 85-220VAC input. Both models operate at 900MHz with 10mW RF power and feature external antennas.

Additional Notes
BU-9H4R-EXT units are internally terminated at 4.3kΩ, with the option for factory removal of termination.
See more

Catalog excerpts

SmaRT DIN-9H4R-2DI Base Unit-1

Engineering SpecSh eet DIN-9H4R-2DI Base Unit For Standard DIN Rail Mounting Features s Spread Spectrum Technology s 4 Form A Relay Contact Outputs s 2 Discrete Inputs s CAN J1939 Connectivity s DIN Enclosure with screw terminal connections s Diagnostic LED indicators s Compact design The SmaRT DIN-9H4R-2DI Base Unit for 24VDC (-24V option) or 120/240VAC (-120 option) industrial control systems features four Form A relays rated at 5A max each, and two discrete inputs. The SmaRT base unit enclosure allows it to be mounted either horizontally or vertically on a standard 35mm DIN rail. SmaRT base units feature seamless association to a SmaRT hand-held unit without the need to open the case. Using Direct Sequence Spread Spectrum (DSSS) wireless technology at 900MHz, the base unit provides a robust direct-line-of-sight link with a SmaRT hand-held remote in congested radio environments. Specifications Power Vin Operating Power Enclosure Dimensions Weight Durability Environment Operating Temp Storage Temp Humidity Radio Frequency RF Power License Modulation Antenna inch: 1.72W x 3.23H x 3.91D mm: 44.61W x 82.04H x 99.21D 4 oz. (113.4 grams) Durable UL94V-0 rated ABS plastic -25°C to 60°C (-13°F to 140°F) -40°C to 85°C (-40°F to 185°F) 0 to 95% non-condensing Size Screwdriver LEDs CAN TX/RX Green - In/Out Green - Health Green/sec - Red or amber/sec - Fault TX/RX Green - Transmit Power Amber - OK Red/Green - Fault Transmit Receive Active Output Active Input OK Outputs Four Relays Form A Form A Rating 2A max @ 250VAC/30VDC inductive load. 5A max resistive load. 10A max. Total Inputs Two SmaRT DIN-9H4R-2DI Base Unit November 2015

 Open the catalog to page 1
SmaRT DIN-9H4R-2DI Base Unit-2

Engineering SpecSheetTerminal Wiring Terminal SmaRTDIN-9H4R-2DI Base Unit ©2015 CERVIS, Inc.November 2015 2 S147.2.0-SmaRT_DIN-9H4R-2DI_BU

 Open the catalog to page 2
SmaRT DIN-9H4R-2DI Base Unit-3

Engineering SpecSheetTerminal Wiring Cont. Options Model SNote: BU-9H4R-EXT units are internally terminated at 4.3kQ. Termination can be removed at the factory. SmaRT DIN-9H4R-2DI Base Unit November 2015

 Open the catalog to page 3

All Cervis catalogs and technical brochures

  1. BU-9H16AF

    2  Pages

  2. BU-xH24XF

    2  Pages

  3. BU-9H18XF

    3  Pages

  4. BU-xH16F

    2  Pages

  5. PG - xH12JS

    2  Pages

  6. BU - x H16R

    3  Pages

  7. LongRT Base

    2  Pages

  8. MINExpo 2016

    1  Page

  9. TM70 CSA/UL

    2  Pages

  10. TM70 Handheld

    2  Pages

  11. IK4

    2  Pages

  12. iK 3

    3  Pages

  13. iK 2

    2  Pages

  14. SmaRT Connect

    2  Pages

  15. SmaRT BU-X00H

    2  Pages

  16. SmaRT BU-XH1R

    4  Pages

  17. SmaRT EBU

    2  Pages

  18. SmaRT PG-XH14

    2  Pages

  19. SmaRT BU-9H8D

    3  Pages

  20. SmaRT BU-xH6R

    3  Pages

  21. SmaRT MCB

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.