Overview: The document provides detailed information on CERTUSS's range of water treatment and steam generation products, including specifications, procedures, and recommendations for use. It covers various types of steam generators, water softening plants, and dosing instruments.
Steam Generators:
  • JUNIOR TC Series: Available in sizes with steam capacities ranging from 80 to 400 kg/h, using oil or gas combustion.
  • UNIVERSAL TC Series: Offers larger capacities from 500 to 1800 kg/h, with options for oil, gas, or combination combustion.
  • ELEKTRO E Series: Electrically heated steam generators with capacities from 8 to 160 kg/h, using power from 6 to 120 kW.
Water Treatment Plants:
  • Water Softening Plants: Utilize ion exchange methods to remove calcium and magnesium ions, preventing scale deposits. Types include CEV (automatic regeneration), CEH (manual regeneration), and CED (twin plant for continuous operation).
  • Water Dosing Plant: Designed to prevent corrosion in steam generators by adding chemicals to the water. The dosing unit ensures precise dosing for long-term protection, suitable for the food industry.
Technical Specifications:
  • Steam capacity and combustion methods are specified for each generator type.
  • Water softening plants have detailed specifications on capacity, throughput, and regeneration processes.
  • Electrical and physical specifications are provided for dosing instruments, including capacity, electrical connection, and dimensions.
Key Recommendations:
  • Proper feed water pre-treatment is crucial for the longevity and efficiency of steam plants.
  • Regeneration of water softening plants should be scheduled outside operational hours to ensure continuous operation.
  • Use of CERTUSS dosing agents is recommended for effective corrosion protection.
See more

Catalog excerpts

Water-softening-1

Plants for Water Treatment Water Treatment Also in product range Steam generators JUNIOR TC series Steam generators ELEKTRO E 6 - 72 M and E 100 - 120 M series Method of heating Electrical 6 - 72 kW Electrical 100 / 120 kW CVE Supply unit as complete ready-to-operate boiler housing installation CERTUSS EXHAUST GAS HEAT EXCHANGERS CERTECON for Junior 80 - 400 as well as CERTECON and ECO SPI for Universal 500 - 1800 DESALINATION HEAT EXCHANGER Heat recycling from the desalination condensate to heat feed water Reduction of the amount of cooling water at steam systems with mixing heat exchangers when waste water cooling is required CERTUSS Dampfautomaten GmbH & Co. KG • Hafenstr. 65 • D-47809 Krefeld Tel.: +49 (0)2151 578-0 • Fax: +49 (0)2151 578-102 www.certuss.com • E-Mail: [email protected]

 Open the catalog to page 1
Water-softening-2

CERTUSSSteam Generators Water Dosing Instrument CERTUSS Water Softening Plants Each steam boiler needs a good feed water pre-treatment which contributes decisively to a long life of the steam plant, its functionality and stability of value. Water mainly contains hardening constituents in very different sizes which inevitably cause scale deposits when vaporizing, followed by a poor heat transmission and an increasing plugging of tanks and tubes. CERTUSS water softening plants work with the ion exchange method. The raw water is lead through a heavy-duty resin. The calcium and magnesium ions are...

 Open the catalog to page 2

Archived catalogs

  1. Elektro E100

    2  Pages

  2. E 100

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.