CTS ATEX Approved Tank Alarm - Manual
1 /4Pages

CTS ATEX Approved Tank Alarm - Manual

CTS ATEX Approved Tank Alarm - Manual
1 /4Pages

Catalog excerpts

CTS ATEX Approved Tank Alarm - Manual-1

INSTRUCTION SHEET The EX Tank Compartment Alert is battery powered and enables the monitoring of the fluid in the remote tank. It may be set to provide a high level / Bund alert audible and visible alarm. It is used in association with a magnetic level switch fitted to the tank. The intended use of the alarm is for industrial applications in hazardous atmospheres of up to Zone 1: gas, vapours and mists. Intrinsically Safe Rating - Ex ia IIB T4 Copy of the certification is available from [email protected] Installation (Typical) Note : Due to the potential electrostatic risk of the plastic membrane and the light metal enclosure the apparatus must NOT be located in a Zone 0 Multiple Level Switches The EX Tank Compartment Alert can monitor the following switches Switch 1 (Probe Connection) Switch 2 (Probe Connection) High / Bund Low / Bund

 Open the catalog to page 1
CTS ATEX Approved Tank Alarm - Manual-2

Testing After unpacking, the unit should be tested before installation. Connect the probe and test the operation of the float to correspond to the correct operation of the alarm. On some probes the float can be reversed to set the desired alarm or some probes have 3 cables so choosing the correct pair is important. If in doubt check operation with a multi test meter before connecting to the alarm. Fitting to the tank A 1.5” M BSP fitting is required if using CTS 5m standard probes. Adjust the probe drop into the tank by pulling the cable through the electric gland on top of the cap and then tightening...

 Open the catalog to page 2
CTS ATEX Approved Tank Alarm - Manual-3

Intrinsically safe parameters J1,J2,J3,J4,J5;RF1 (COMBINED) U0 = I0 = P0 = C0 = L0 = Ci = Li = Note: the above load parameters apply where : a) The external circuit contains no combined lumped inductance Li and capacitance Ci greater than 1% of the above valves. or b) The inductance and capacitance are distributed as in a cable. or c) The external circuit contains only lumped inductance or only lumped capacitance in combination with a cable. In all other situations, e.g. the external circuit contains combined lumped inductance and capacitance up to 50% of each of the inductance and capacitance...

 Open the catalog to page 3
CTS ATEX Approved Tank Alarm - Manual-4

Mounting holes Diagonally 180mm 90mm 58mm