MARS 6 - 1

SPECIFICATIONS Overall Instrument Dimensions 63.5 cm (25 in.) height x 53.3 cm (21 in.) width X 63.5 cm (25 in.) depth 7” (800 x 480) TFT-LED glass capacitive touchscreen display A combination of vessel recognition and vessel counting sensor technology, software technology, and applications knowledge that enables a user to select a One Touch method that matches their sample type. Based on the sample type, One Touch Technology determines the vessel type and count, digestion temperature, ramp and hold times, and microwave power input. Power control technology provides the maximum amount of energy to the sample to ensure complete digestions. All sensors, including pressure and temperature sensing devices located within the microwave cavity, are microwave-transparent or shielded to ensure accurate readings and to eliminate arcing (ignition) hazards. Software available in English, German, French, Italian, Spanish, Chinese, and Japanese. Sample Stirring In-vessel magnetic stirring of samples at three levels of speed. Turntable Design PerfectCircle™ design provides absolute radial symmetry. Turntable operates in alternating or continuous mode. Inlet/Outlet Ports Standard 0.500” I.D. port or optional 0.3125” I.D. ports for 0.250” (6mm) tubing Microwave Cavity Heavy-duty, multi-layer Teflon® coating Electrical Requirements Magnetron Frequency Power Output 1800 W – Continuous power available at all power levels to provide more control for reactions. (IEC 705 Method – 1988) Magnetron Protection Solid-state isolator (US patent 4,835,354) to protect magnetron from reflected energy, ensuring constant power output. Onboard thermal printer and USB-B compatible printer port Safety Features Three independent door safety interlocks, including an interlock monitoring system plus three independent thermal switches, are used in each instrument to prevent instrument operation and microwave emissions in case of improper door closure or misalignment. The instrument complies with HHS standards under 21 CFR, Part 1030.10, Subparts (C)(1), (C)(2) and (C)(3). Reactiguard continuously monitors the cavity and disables the magnetron if disturbances occur inside the cavity. CEM Corporation PO Box 200 Matthews, NC 28106 Tel: 800-726-3331 Tel: 704-821-7015 Fax: 704-821-7894 Email: info@cem.com www.cem.com Emissions and Safety Approvals Europe/Global Community Conforms to EN61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 1) Conforms to EN61326-1 (EMC requirements for Electrical, Control and Laboratory Use) United States Complies with FCC Part 18 regulations (47CFR part 18: Industrial, Scientific and Medical Equipment) US Safety Approval to UL61010-1 (ETL Testing Laboratories) Canada Complies with FCC Part 18 regulations (47CFR part 18: Industrial, Scientific and Medical Equipment) Canadian Safety Approval to CAN/CSA C22.2 No. 61010.1 CEM microwave systems and vessel designs may be covered by any one of the following US patents: 04835354, 04080168, 05369034, 04672996, RE034373, 05230865, 04877624, 04672996, 05206479, 05427741. Other patents pending. Teflon® is a registered trademark of DuPont. TFM® is a registered trademark of Hoechst A.G. MARS™, MARSXpress™, One Touch™, PowerMAX™, DuoTemp™, EnergySeal™, and Thermo-Optic™ are all trademarks of CEM Corporation. France CEM μWave S.A.S. Immeuble Ariane Domaine Technologique de Saclay 4, rue Rene’ Razel 91892 ORSAY Cedex Tel: 33 (01) 69 35 57 80 Fax: 33 (01) 60 19 64 91 Email: info.fr@cem.com www.cemfrance.fr Germany, Austria, Switzerland CEM GmbH Carl-Friedrich-Gauss-Str.9 47475 Kamp-Lintfort Tel: (49) 2842-9644-0 Fax: (49) 2842-9644-11 Email: info@cem.de www.cem.de Ireland CEM Technology (Ireland) Ltd. Sky Business Centre 9a Plato Business Park Damastown Dublin 15 Tel: +353 (0) 1 885 1752 Fax: +353 (0) 1 885 1601 Email: info.ireland@cem.com www.cemmicrowave.co.uk Italy CEM S.R.L. Via Dell’ Artigianato, 6/8 24055 Cologno al Serio (Bg) Tel: (39) 35-896224 Fax: (39) 35-891661 Email: info.srl@cem.com www.cemmicroonde.com Japan CEM Japan K.K. 2-18-10 Takanawa Minato-ku, Tokyo 108-0074 Tel: +81-3-5793-8542 Fax: +81-3-5793-8543 Email: info@cemjapan.jp www.cemjapan.co.jp United Kingdom CEM Microwave Technology Ltd. 2 Middle Slade Buckingham Industrial Estate Buckingham MK181WA Tel: (44) 1280-822873 Fax: (44) 1280-822342 Email: info.uk@cem.com www.cemmicrowave.co.uk

Open the catalog to page 1
MARS 6 - 2

Service & Support All CEM Systems are backed by our experienced applications support team and award-winning service department. CEM’s factory-trained field technicians and in-house service team are well known in the industry for their prompt response and problem-solving capabilities. MARS Classic Vessel Technology Designed with flexibility in mind, MARS 6 also runs all previous vessels from the CEM MARS and MDS vessel families. About CEM Since 1978, CEM has been the world’s leading provider of microwave laboratory systems with a complete portfolio of award-winning instruments and...

Open the catalog to page 2
MARS 6 - 3

VESSEL TECHNOLOGY As the proven innovator in CAD-designed vessel technology, CEM led the way with the original patented vent-and-reseal vessel for our first generation MDS-81D in 1985. Since then, we have designed and improved upon a wide variety of vessels for an array of chemistries. Our revolutionary open architecture, closed vessel design cools faster than any other microwave vessel — no need for chillers, water baths or external cooling systems — and our composite vessel sleeves give added strength, ensuring that you can depend on CEM vessels to be strong and effective. Our newest...

Open the catalog to page 3
MARS 6 - 4

SOFTWARE CONTROL & FLEXIBILITY The MARS 6 can be controlled using the onboard touchscreen interface. HIGH-RESOLUTION, FULL COLOR TOUCHSCREEN WITH SPEAKERS Large 7” (800 x 480) glass capacitive LED screen serves as controller and display Simple Method Programming 8-GIGABYTE ONBOARD CONTROLLER No need for a laptop or external controller POWERMAX™ POWER CONTROL Delivers maximum energy to the sample, ensuring complete digestions ONE TOUCH OR MARS CLASSIC METHOD PROGRAMMING Select which program is best for you ACID- AND IMPACT-RESISTANT COMPOSITE SHELL Better system protection in a laboratory...