1. Catalogs
  2. CELSA MESSGERATE ESPAÑA S.L.
  3. 05-Current transformers - AST Line

05-Current transformers - AST Line

05-Current transformers - AST Line
1 / 32 PagesView full catalog

05-Current transformers - AST Line

Product catalog summary
Overview: The document outlines the technical specifications and features of AST-Line current transformers by Celsa Messgerate España S.L., emphasizing their modern design, safety features, versatility, and compliance with international standards.
Safety Features: AST-Line transformers are designed with overlapping housing halves for enhanced safety, insulated protective caps for primary fixing bolts, and extended secondary terminal covers to increase air gaps and creepage distances.
Versatility: These transformers can be easily secured and removed using a form-locking guide. Secondary wire leads can be connected through rectangular openings or lateral slots, enhancing their adaptability.
Secondary Terminal System: The CELSA clamping system uses a nut to apply pressure, ensuring a secure connection without damaging the conductor. Terminals are made of brass with nickel plating, facilitating easy short-circuiting during operation.
Compliance and Features: The transformers comply with EN 60044, DIN VDE 0414, and other standards. They feature unbreakable polyamide casings, nickel-plated terminals, and are designed for rated frequencies of 50-60Hz. They have a rated short-time thermal current of Ith = 60 . IN and a nominal surge current of Idyn = 2.5 . Ith.
Accessories and Options: Various accessories such as mounting feet, snap-on brackets, and copper tubes are available. Special executions can be requested for different ranges, classes, or rated burdens.
Technical Specifications: Detailed specifications for different models (e.g., ASTR21, ASTMR21, AST210s) are provided, including dimensions, primary rated currents, and rated burdens for different classes.
General Mechanical Features: The transformers are constructed with unbreakable polyamide plastic casing, flame retardant and self-extinguishing as per UL 94 V0 standards, and equipped with nickel-plated secondary terminals with plus-minus screws (2 Nm).
General Electrical Features: Rated frequency is 50-60Hz, with insulation class E. They have a rated short-time thermal current of Ith = 60 . IN, nominal surge current of Idyn = 2.5 . Ith, maximum voltage for equipment Um = 0.72kV, and a rated power-frequency withstand voltage of 3kV/1min. Instrument security factor options are FS5 or FS10.
Model-Specific Details: Various models are detailed, such as AST640, AST815, AST830, each with specific dimensions, suitable conductor sizes, and rated current ranges.
Contact Information: For further inquiries, Celsa Messgerate España S.L. can be contacted via their website or email, with contact details provided in the document.
See more

Catalog excerpts

05-Current transformers - AST Line-1

CURRENT TRANSFORMERS AST - Current transformers line Technical comments Versatility Modern design, versatility and greater safety are the distinctive features of Current transformers are frequently secured with the help of a lug through the new AST-Line. In developing we have moreover retained our reliable which a clamping screw fits onto the primary bar. You must have noticed what CELSA secondary terminal. a nuisance this lug can be, for instance when you want to install the CT behind fuse switch disconnectors, fuse trips or between bar overlaps and exits. Greater safety The new current transformer of the CELSA AST-Line have their own solution The joining point where the two halves of the housing meet inside the primary to this problem. The conventional fixing device has been designed with a bar opening is crucial to safety. Quite in accordance with CELSA´s motto - form-locking guide so that - if necessary - it can simply be pulled out. safety is built into our products - the two halves of the housing are not aligned with a butt joint, instead they are made to overlap in the new AST-Line. Insulated protective caps for primary fixing bolts Extended secondary terminal cover To protect against unintentional contact the bolts of the primary fixing devices When using the CT as a tube type CT you may wish to increase the air gaps can be covered by protective insulation caps. These should be pressed only and creepage distances between secondary terminals and primary bars. You on the already fastened bolts, not between bolts and bars. can do so by adding protective terminal covers over the CT openings on the front and back as shown. Celsa Messgerate España S.L. www.celsamessgerate-spain.com [email protected] / +34 96 130 93 78

 Open the catalog to page 1
05-Current transformers - AST Line-2

CURRENT TRANSFORMERS AST - Current transformers line General Features Secondary terminal openings. Of course all AST current transformers comply with EN 60044, DIN VDE The connection of secondary wire leads to their corresponding terminals is normally done by sliding them into the rectangular openings on the front or the back. If this way of connection is prohibited for instance due to blocking when mounted right behind a line of fuses the secondary wire leads equipped General Mechanical Feature with clamps can also be introduced into the lateral slots for secondary termi- • unbreakable plastic...

 Open the catalog to page 2
05-Current transformers - AST Line-3

CURRENT TRANSFORMERS ASTR21 - WINDOW CURRENT TRANSFORMER Round conductor: Accesories: • Mounting feet (2 pieces) General Mechanical Feature • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing Special executions (On request): • nickel-plated secondary terminals with plus minus screws (2 Nm) • Other ranges, classes or rated burden VA. • integrated secondary terminal caps General Electrical Features • rated frequency 50-60Hz (other frequencies on request) • class of insulation E (other classes on request) • rated short-time thermal current...

 Open the catalog to page 3
05-Current transformers - AST Line-4

CURRENT TRANSFORMERS ASTMR21 - WINDOW CURRENT TRANSFORMER Round conductor: Accesories: • Mounting feet (2 pieces) General Mechanical Feature • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing Special executions (On request): • nickel-plated secondary terminals with plus minus screws (2 Nm) • Other ranges, classes or rated burden VA. • integrated secondary terminal caps General Electrical Features • rated frequency 50-60Hz (other frequencies on request) • class of insulation E (other classes on request) • rated short-time thermal current...

 Open the catalog to page 4
05-Current transformers - AST Line-5

CURRENT TRANSFORMERS AST210s - WINDOW CURRENT TRANSFORMER Round conductor: Primary bar: Accesories (please indicate in the order): General Mechanical Feature • Mounting feet (2 pieces) • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • primary fixing device • nickel-plated secondary terminals with plus minus screws (2 Nm) • integrated secondary terminal caps Special executions (On request): • Other ranges, classes or rated burden VA. General Electrical Features • rated frequency 50-60Hz (other frequencies on request) • class of insulation...

 Open the catalog to page 5
05-Current transformers - AST Line-6

CURRENT TRANSFORMERS AST255s - WINDOW CURRENT TRANSFORMER Round conductor: Primary bar: Accesories (included in the delivery): • Mounting feet (2 pieces) General Mechanical Feature • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing Special executions (On request): • nickel-plated secondary terminals with plus minus screws (2 Nm) • Other ranges, classes or rated burden VA. • integrated secondary terminal caps General Electrical Features • rated frequency 50-60Hz (other frequencies on request) • class of insulation E (other classes on request)...

 Open the catalog to page 6
05-Current transformers - AST Line-7

CURRENT TRANSFORMERS AST310s - WINDOW CURRENT TRANSFORMER Round conductor: Primary bar: Accesories (please indicate in the order): sec. 5 A / Rated burdens VA Class 0.5 2.5 3.75 3.75 5 General Mechanical Feature • Mounting feet (2 pieces) • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing • primary fixing device • nickel-plated secondary terminals with plus minus screws (2 Nm) • integrated secondary terminal caps Special executions (On request): • Other ranges, classes or rated burden VA. General Electrical Features • rated frequency 50-60Hz...

 Open the catalog to page 7
05-Current transformers - AST Line-8

CURRENT TRANSFORMERS AST3R30 - WINDOW CURRENT TRANSFORMER Round conductor: Accesories: • Mounting feet (2 pieces) General Mechanical Feature • unbreakable plastic casing, polyamide • difficult to inflame, according to UL 94 V0 and selfextinguishing Special executions (On request): • nickel-plated secondary terminals with plus minus screws (2 Nm) • Other ranges, classes or rated burden VA. • integrated secondary terminal caps General Electrical Features • rated frequency 50-60Hz (other frequencies on request) • class of insulation E (other classes on request) • rated short-time thermal current...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.