BTS-6
3Pages

{{requestButtons}}

Catalog excerpts

BTS-6 - 1

TECHNICAL DATA SHEET: BTS-6 For multiple use for nonstructural applications in cracked concrete Resistencia al Fire resistance fuego clase class BASE MATERIALS • • • ETA approved (ETA 16-0848). Approved for cracked and non cracked concrete for redundant non-structural systems. Multi-application. You can install M6-M8 clamps, fix supports or channels, install threaded bars, ... Two embedment depths (35/50 mm). No expansion. Low edge distance and spacing between anchors. One piece anchor. Low install torque using nut setter that allow the installation of three references, screw, rod and nut. Removable. High resistance to vibrations. Immediate load. No need to wait. Allows the installation with drilling machine using the drill, the adapter and nut setter. Fire resistance homologated. Material: manufactured in hardened steel Coating: organic coating Zn-Al flakes > 240H in SST. Concrete Solid brick Prefabricated hollow concrete slabs INSTALLATION TOOLS With set adaptor Small Things Matter C/ Roselló, 7 Pol. Ind. La Bruguera Castellar del Vallés (BCN – Spain) Tel: +34 93 715 33 33 This document is intellectual property of CELO FIXINGS Copy is forbidden and will be prosecuted. Copy, total or partial, must have the written agreement of CELO FI

Open the catalog to page 1
BTS-6 - 2

TECHNICAL DATA SHEET: BTS-6 INSTALLATION PROCEDURE Fast anchor in concrete, only three steps: drill, clean and thread. If you use a drilling machine, you need to use adaptor to thread the anchor. INSTALLATION PARAMETERS Embedment depth hnom Effective depth heff Characteristhic spacing between anchor Scr (mm) Characteristic edge distance Ccr (mm) Minimum spacing between anchor Smin (mm) Minimum edge distance Cmin (mm) Minimum concrete thickness hmin (mm) Max. installation torque Timp impact wrench (Nm) PERMISSIBLE LOADS (1) Allowable loads without influence of edge spacing and distance. (2)...

Open the catalog to page 2
BTS-6 - 3

TECHNICAL DATA SHEET: BTS-6 LOADS, SPACING AND EDGE DISTANCE IN PREFABRICATED HOLLOW CONCRETE ≥ C45/55 Allowable load in any direction (1) (2) hnom = 35 mm F per [kN] Bending moment permitted Distance between anchors (1) Allowable loads without influence of edge spacing and distance. (2) The load figures include the partial safety factors of the resistors as per approval and a partial safety factor in action of ϒF = 1.4. If the characteristic distances (Ccr or Scr) are not met, the loads must be reduced. The minimum distances (Smin, Cmin) must always be observed. Loads, spacing and edge...

Open the catalog to page 3

All CELO catalogs and technical brochures

  1. IPD

    2 Pages

  2. MFR

    5 Pages

  3. CET

    1 Pages

  4. VELOX® Pozi

    3 Pages

  5. Torab® P

    1 Pages

  6. TKA

    3 Pages

  7. Cavity fixings

    16 Pages

  8. FORCE ONE

    16 Pages

  9. ResiTHERM®

    30 Pages