SUP11

SUP11

SUP11

Product catalog summary
Applications:
The SUP11 off-center load cell is suitable for small capacity weighing systems, including small weighing platforms and hopper weighing.
Main Features:
  • Universal use
  • Low cost
  • Aluminium construction
  • Independent from the center of load application
  • Platform size: 150x150 mm
Nominal Load: 0.3, 0.5, 0.6, 1, 1.5, 2 kg
Specifications:
  • Rated output: 1.5±10% mV/V (for ≤0.5Kg)
  • Zero balance: ±2% FS
  • Non-linearity: 0.03% FS
  • Hysteresis: 0.03% FS
  • Non-repeatability: 0.02% FS
  • Creep (30 min): 0.03% FS
  • Temperature effect on output: 0.03% FS/10°C
  • Temperature effect on zero: 0.03% FS/10°C
  • Input impedance: 410±15Ω
  • Output impedance: 350±3Ω
  • Insulation: >2000Ω/50VDC
  • Recommended excitation: 10V
  • Max. excitation: 15V
  • Compensated temperature range: -10°C to +40°C
  • Operating temperature range: -20°C to +60°C
  • Safe overload: 150% FS
  • Ultimate overload: 200% FS
  • Cable size: Φ3x450mm
  • Protection class: IP65
Note: Specifications are subject to change without notice.
See more

Catalog excerpts

SUP11-1

OFF CENTER LOAD CELL TYPE SUP11 APPLICATIONS: Off center load cell type SUP11 can be used in small capacity weighing systems. Some applications are: - Small weighing platforms - Hopper weighing, etc. MAIN FEATURES: - Universal use Low cost Aluminium construction Independent from centre of load application Platform size 150X150 mm NOMINAL LOAD: kg 0,3-0,5-0,6-1-1,5-2 SPECIFICATIONS: Rated output Zero bilance Non-linearity Hysteresis Non-repeatability Creep (30min) Temp. effect on output Temp. effect on Zero Input impedance Output impedance Insulation Recommended excitation Max. excitation Compensated Temp. range Operatine Temp. range Safe overload Ultimate overload Cable size Protection class CELMI s.r.l. Largo Brugnatelli 13/16 20090 BUCCINASCO (MI) ITALY Tel: +39-0245712209 / 0257503712 Fax: +39-0245705836 / 0257506211 Internet: www.celmi.com mail: [email protected]

 Open the catalog to page 1
SUP11-2

SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 2

All Celmi catalogs and technical brochures

  1. BSW-P

    1  Page

  2. H9Z2

    2  Pages

  3. Type 387

    2  Pages

  4. BM6G

    2  Pages

  5. SUS

    2  Pages

  6. SUP14

    2  Pages

  7. L6F

    2  Pages

  8. L6W

    2  Pages

  9. L6T

    2  Pages

  10. SUP13

    2  Pages

  11. SUP12

    2  Pages

  12. SUP7

    2  Pages

  13. SUP6

    2  Pages

  14. SUP2

    2  Pages

  15. SUP1

    2  Pages

  16. L6G

    2  Pages

  17. L6E

    2  Pages

  18. L6N

    2  Pages

  19. L6D

    2  Pages

  20. L6D15

    2  Pages

  21. L6J1

    2  Pages

  22. L6E3

    2  Pages

  23. L6B

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.