Applications: The Low Profile Load Cell Type 142 is suitable for use in small, medium, and high-capacity weighing systems. It is commonly applied in weighing hoppers, tanks, silos, and platforms.
Main Features: This load cell is water-proof, highly resistant to side loads, and made of stainless steel. It offers options for double bridge output for redundancy, CIA 404 output, and analog output of 4-20mA. It is soldered with microplasma and supports a standard nominal load range from 500 to 150,000 kg, with high precision equivalent to OIML C3 standards.
Specifications: According to VDI/VDE 2637, the load cell has a combined error of 0.020% Ln, nominal load range from 0.5 to 150 tons, initial load of 25% Ln, maximum load of 150% Ln, non-linearity of 0.02% Ln, hysteresis error of 0.015% Ln, repeatability error of 0.01% Ln, and a 30-minute creep of 0.02% Ln. The nominal temperature range is -10°C to +40°C, with zero and output temperature drifts over 10°C at 0.009% Cn. The thermal gradient is less than 5°K/h.
Electrical Data: The nominal output is 2 mV/V with a tolerance of ±0.1% Cn. The nominal supply voltage ranges from 1 to 24V, with a maximum supply voltage of 30V. Input resistance is 850Ω ±10%, output resistance is 700Ω ±1%, and insulation resistance at 20V is greater than 2000 MΩ. Zero output tolerance is ±1% Cn.
Mechanical Data: The breaking load is greater than 250% Ln, maximum side load is 300% Ln, deflection is less than 0.3 mm, cable length is 5 meters, and weight ranges from 1.5 to 7.5 kg.
Environmental Conditions: The working temperature range is -40°C to +80°C, with the same range for storage temperature. The housing protection is rated at IP66/68.
Note: Specifications are subject to change without notice.
See more

Catalog excerpts

LOW PROFILE LOAD CELL TYPE 142-1

LOW PROFILE LOAD CELL TYPE 142 APPLICATIONS: The low profile load cell type 142 can be used in small, medium and high loading capacity weighing systems. CELMI s.r.l. Largo Brugnatelli 13/16 20090 BUCCINASCO (MI) ITALY Tel +39-0245712209 Fax +39-0245705836 Internet: www.celmi.com Some applications are: - Weighing in hoppers, tanks, silos, etc. - Weighing platforms MAIN FEATURES: - Water-proof - Side load high resistance - Stainless steel - Available with double bridge output (for redundant system) - Available with output (CIA 404) - Available with analog output 4-20mA - Soldered with microplasma - Standard nominal load from 500 to 150.000 kg - High precision (equivalent to OIML C3) NOMINAL LOAD: ton 0.5-1-2-5-7,5-10-15-20-30-50-100-150 S P E C IF IC A T IO N A C C O R D IN G T O V D I /V D E 2 6 3 7 M E T R O L O G IC A L C H A R A C T E R IS T IC S P a r . U n . C O M B I N E D E R R O R F c o m b % L n 0 , 0 2 0 N O M IN A L L O A D L n t 0 ,5 ÷ 1 5 0 IN IT IA L L O A D L p % L n 2 5 M A X IM U M L O A D L l % L n 1 5 0 N O N - L IN E A R ITY F lin % L n 0 ,0 2 H IS TE R E S IS E R R O R F u % L n 0 ,0 1 5 R E P E A TA B IL ITY E R R O R F v % L n 0 ,0 1 C R E E P - 3 0 M IN U TE S F c r % L n 0 ,0 2 N O M IN A L TE M P E R A TU R E R A N G E B tn ° C - 1 0 + 4 0 ZE R O TE M P E R A TU R E D R IF T (O V E R 1 0 °C ) TK 0 % C n 0 ,0 0 9 O U TP U T TE M P E R A TU R E D R IF T (O V E R 1 0 °C ) TK C % C n 0 ,0 0 9 TH E R M A L G R A D IE N T ° K /h < 5 E L E C T R IC A L D A T A N O M IN A L O U TP U T C n m V /V 2 N O M IN A L O U TP U T TO L E R A N C E D c ± % C n 0 ,1 N O M IN A L S U P P L Y V O L TA G E B s u V 1 ÷ 2 4 M A X IM U M S U P P L Y V O L TA G E U sm a x V 3 0 IN P U T R E S IS TA N C E R e Ù 8 5 0 ± 1 0 % O U TP U T R E S IS TA N C E R a Ù 7 0 0 ± 1 % IN S U L A TIO N R E S IS TA N C E @ 2 0 V R is M Ù > 2 0 0 0 Z E R O O U T P U T T O L E R A N C E D o ± % C n 1 M E C H A N IC A L D A T A B R E A K IN G LO A D L d % L n > 2 5 0 M A X IM U N S ID E L O A D L lq % L n 3 0 0 D E F L E C TIO N h n m m < 0 .3 C A B L E L E N G TH m 5 W E IGHT K g 1 . 5 ÷ 7 .5 E N V IR O N M E N T A L C O N D IT IO N S W O R K IN G TE M P E R A TU R E R A N G E B tn ° C - 4 0 + 8 0 S TO R A G E TE M P E R A TU R E R A N G E B ts °C - 4 0 + 8 0 H O U S IN G P R O TE C TIO N I P 6 6 / 6 8 SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 1
LOW PROFILE LOAD CELL TYPE 142-2

i r -0"B"- 0*C* I- DRPERING INFORMATION 142-XXX-XחSEE TECHNICAL DATA __I_ I R 1/4- NOMINAL LOAD *A' 'B* "C *D* *G* 'H* 500K 500Kq 1T lt 2T 2t 66 82 22 11 44 8 M6 70 5T 5t 7.5T 7,5t 10T 20T o-t 20-t 74 99 28 11 48 15 M10 80 30T 30-t 88 126 35 12 54 15 M12105 50T 100T 50-t oo-t 107164 55 15 65 20 M16130 150T 150-t STANDA 107164 55 ?D LENGHT 5m 13 71 i 20 M16130 -0"H" N' 3 120' HOLES (SEE NOTE 1) WITH THREAD "G" NOTE 1) N* 4 HDLE AT 90* BETWEEN IT AND RDTATE DF 45' FOR 150TDNS MDDEL SHELDED PDLYURETHANE CABLE WITH 4X0,35mi«r8X0,125mr« ? TYPE 142-XX-supply E BRIDGE AND UBLE BRIDGE □THER LENGHT DN...

 Open the catalog to page 2

All Celmi catalogs and technical brochures

  1. BSW-P

    1  Page

  2. H9Z2

    2  Pages

  3. Type 387

    2  Pages

  4. BM6G

    2  Pages

  5. SUS

    2  Pages

  6. SUP14

    2  Pages

  7. L6F

    2  Pages

  8. L6W

    2  Pages

  9. L6T

    2  Pages

  10. SUP13

    2  Pages

  11. SUP12

    2  Pages

  12. SUP11

    2  Pages

  13. SUP7

    2  Pages

  14. SUP6

    2  Pages

  15. SUP2

    2  Pages

  16. SUP1

    2  Pages

  17. L6G

    2  Pages

  18. L6E

    2  Pages

  19. L6N

    2  Pages

  20. L6D

    2  Pages

  21. L6D15

    2  Pages

  22. L6J1

    2  Pages

  23. L6E3

    2  Pages

  24. L6B

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.