Converter of signals and conditioner of analog sensors fo strain gauges, DIN rail format APPLICATIONS • Conditioning of any kind of analog signal coming from a sensor to fit with data acquisition systems or Programmable Logic Controller (PLC) • Electrical and physical measurement: strength, torque, pressure, displacement, acceleration, strain gauges..., on test bench or control of industrial process. The single channel measurement model ME520 provides very complete analog outputs for measurement, conditioning and conversion of signals such as strength, torque, pressure, displacement, acceleration sensors or strain gauges. Three parameters can be adjusted with an easy procedure that allows output trimming depending on the sensor: • A potentiometer to trim gain • A potentiometer to trim zero • A push button to trim calibration A wide range of options is available: isolated power supply and many other sensors adapted to ME520 or ME52C. A brand of S PHEREL System. www.meiri.com - www.celians-shop.com
Open the catalog to page 1Converter of signals and conditioner of analog sensors fo strain gauges, DIN rail format TECHNICAL FEATURES Isolated general supply Operating temperature range Storage temperature range Dimensions of raim DIN unit Connectors Approx. Weight (without option) Input Analog output Precision Bandwidth Calibration trim Full bridge Excitation bridge Zero adjustment Gain adjustment Sensitivity 4 x 3 limots About 110 grams 1 sensor or 4x 350ohm sensors set up in bridge, trimmed together an supplied with 5Vdc Jumper switch configuration: 0-10V ; ±10,0-20mA ;4- Jumper switch configuration: 2KHz ou 20KHz...
Open the catalog to page 2