1. Catalogs
  2. celduc relais
  3. HIGH VOLTAGE RELAYS

HIGH VOLTAGE RELAYS

HIGH VOLTAGE RELAYS

HIGH VOLTAGE RELAYS

Product catalog summary
Main Characteristics:
These high voltage reed relays with dry contacts are designed for printed circuit boards or can be fixed with screws. They feature one normally open contact and are encased in a plastic cover. The maximum switching voltage is 7500 VDC or peak, with a maximum switching current of 200 mA and a nominal current of 3 A. The contact rating is 50 W. These relays are available without screws.

Electrical Data:
The initial contact resistance is ≤ 150 mΩ at 100 mA/12 VAC. Coil resistance varies by model: R1380 is 75 Ω ± 10%, R1329 is 300 Ω ± 10%, and R1343 is 1200 Ω ± 10%. The hold-on voltage is 10000 VDC across contacts and 14000 VDC between coil and contacts. Insulation resistance is 1012 Ω for both across contacts and between coil and contacts. The resonance frequency of the switch is 900 Hz, with an operate time of 4 ms and a release time of 0.5 ms.

Physical Data:
The operating temperature ranges from -25 to +70 °C, and the storage temperature ranges from -40 to +85 °C. The maximum weight is 28 grams. The relays can withstand shocks of 50 g for 11 ms and vibrations from 50 to 500 Hz at 30 g.

Control Data:
The nominal voltage varies by model: 6 V for R1380, 12 V for R1329, and 24 V for R1343. The operate voltage to secure function ranges from ≤ 4.4 V to ≤ 17.6 V, and the release voltage is ≥ 0.5 V to ≥ 2 V. Power dissipated on the coil at 20 °C is 480 mW.

For further details on 5KV types, consultation is advised. All technical characteristics are subject to change without prior notice.
See more

Catalog excerpts

HIGH VOLTAGE RELAYS-1

RELAIS REED HAUTE TENSION A CONTACT SEC HIGH VOLTAGE REED RELAY/ DRY CONTACT Pour For printed circuit board or fixing screws Un contact normalement One normally open contact sous capot plastique/ in plastic cover caractéristisques principales/ main characteristics tension maximale de commutation/ maximum switching voltage peak) courant maximal de commutation / maximum switching current courant traversant/ nominal current 3 A puissance maximale/ contact rating Ces relais sont disponibles sans vis de fixation (voir ci dessous) available without screw ( see below) REF. R1380 L87 R1329 L87 R1343 L87 Proud to serve you All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis.

 Open the catalog to page 1
HIGH VOLTAGE RELAYS-2

caracteristiques de controle/control data_ consommation nominale a 20 °C/power dissipated on the coil at 20 °C 480 mW tension nominale/nominal voltage 6 V 12 V 24 V tension d'action/'operate voltage to secure thefunctionfrom -25 to + 70 °C < 4,4 V < 8,8 V < 17,6 V tension de rdachement/refease voltage > 0,5 V > 1 V > 2 V caracteristiques electriques/electrical data tension de tenue/ hold-on voltage - entre lames/ accross contacts - entre bobine et contact/ between coil and contacts resistance d'isolement/ insulation resistance - entre lames/ accross contacts - entre bobine et...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.