Oxygen Compressor OXICOMP3 Micro-controlled, low rpm, And oil free, to fill in cylinders Feed pressure according on model from 2 to 6 bar (29 to 87 psi) Selectable filling pressure, maximum 200 bar (2,900 psi) Maximum cylinder filling volume 4050 l/h (4 m3/h) Fill in capacity in 24 hours 48 cylinders of 10 lit The high pressure OXICOMP oxygen compressors, oil-free, includes very low revolution-per-minute (RPM) special geared motors, making it possible to extend the time between maintenance checks. With an innovative compression system, cooled by air and coolant. The oxygen leaves the booster at low temperature The OXICOMP compressors use two external oil free floating pistons. These pistons are mounted, with the use of rods, on a transverse axis which acts as crankshaft, facilitating the easy removal of the cylinder-piston-rod assembly for maintenance operations. The pistons may be very easily dismounted in order to carry out a replacement or a simple change of segments (rings). Similarly, there are external stainless steel valves, linings and o-rings manufactured with anti-explosion treatment and designed for heavy-duty work. Our Oxygen Compressor is CE certified and can compress oxygen, helium, nitrogen and other clean and dry gases. CHARACTERISTICS MODELS OXICOMP 3 Load pressure (selectable) 100 - 150 - 200 bar. (1450 – 2175 – 2900 psi) Electricity power 230 - 400V- 50/60 Hz Engine power 3 Kw three phase (4.02 HP) Electricity consumption 3.2 Kw RPM (very low) 28 rpm Connection ¼ ʺ NPTF Weigh 310 Kg Dimensions (wheels 85 mm) Length 545 x Width 570 x High 1020 mm. Weigh packaged 364 Kg Volume packaged 1.02 m3 (882x 840 x 1390 mm) Rv.1-03/01/2013 Ceimsa reserves the right to change specifications or dimensions without prior notice. CEIMSA ELECTROMEDICINA S.L. Polígono Mugazuri, 6 A – 31600 BURLADA (Navarra) – SPAIN Tel.: 34 948 131 776 - Fax: 34 948 124 470 e-mail: [email protected] http://www.c
Open the catalog to page 1Oxygen Compressor OXICOMP3 Micro-controlled, low rpm, And oil free, to fill in cylinders STANDARD COMPONENTS -Electronic circuit -Incoming oxygen deposit -Incoming pressure regulator -Geared motors -Pressure transducer -Lower piston -Safety valve -Upper piston -Decompression valve -Refrigeration elements -Antireturn Valve - Start/Stop Buttons -Refrigerant ventilator - Emergency Stop AUTOMATISM IN THE FEED AND FILLING PRESSURE This compressor works with a feeding pressure from 2 to 6 bar (29 to 87psig.) so if the pressure falls below this assigned value, the compressor stops and remains on standby...
Open the catalog to page 22 Pages
2 Pages