PPA40L

PPA40L

PPA40L

Product catalog summary
Overview: This document provides technical specifications and testing procedures for the PPA40L actuator by Cedrat Technologies. It outlines standard properties, factory tests, and optional configurations.
Technical Specifications:
  • Displacement: Max no-load displacement is 44.32 µm under quasistatic excitation, with a range of 40 to 64 µm.
  • Force: Blocked force is 2957 N, ranging from 2514 to 3401 N.
  • Stiffness: Measured at 66.73 N/µm, with a range of 53.38 to 73.40 N/µm.
  • Resonance Frequency: 14250.90 Hz under harmonic excitation, with a range of 12113 to 15676 Hz.
  • Response Time: 35.09 µs, ranging from 31.58 to 40.35 µs.
  • Capacitance: 13.30 µF, with a range of 11.97 to 17.29 µF.
  • Max Tensile Force: 1200 N, with a minimum of 900 N.
  • Resolution: 0.44 nm.
  • Dimensions: Height is 57 mm, depth is 23.5 mm, and width is 18 mm.
  • Mass: 92 g.
Testing Procedures:
  • Electrical admittance vs. frequency (free-free).
  • Displacement vs. input voltage.
  • Gain and linearity of the sensor.
  • Step response in closed loop.
  • Stability in closed loop.
Optional Configurations:
  • Mechanical interfaces: Flat, threaded, or specific interfaces.
  • Additional options: Strain gauges, vacuum compatibility, and custom versions.
Environmental Conditions: Tests are conducted at ambient temperature (15-25°C) and dry air (humidity < 50% rH). Deviations from these conditions may affect performance.
See more

Catalog excerpts

PPA40L-1

copyright © cedrat technologies | 03/2014 www.cedrat-technologies.com | [email protected] ^ CEDRAT < , TECHNOLOGIES\ \ Innovation in Mechatronics > TABLE OF STANDARD PROPERTIES OF USE AND MEASUREMENT The properties defined in the table below, are set up according to the technical conditions of use and measurement. These properties are warranted within their variation range and in compliance with the standard technical conditions of use. Notes Max. no load displacement Blocked force Stiffness Resonance frequency (free-free) Response time (free-free) Capacitance Max. tensile force Resolution Height (in actuation direction) Depth (base) Width (base excl. wedge & wires) Width (base incl. wedge & wires) Mass Standard mechanical interface (top) Standard mechanical interface (base) Standard electrical interface STANDARD TECHNICAL CONDITIONS Quasistatic excitation, blocked-free Quasistatic excitation, blocked-free Quasistatic excitation, blocked-free Harmonic excitation, free-free, on the admittance curve Harmonic excitation, free-free, on the admittance curve Quasistatic excitation, free-free, on the admittance curve Static effort, blocked-free Quasistatic excitation 1 centered M3 threaded hole 5 mm deep & 4 M2.5 threaded holes on 0 15 mm 4 mm deep 1 centered M3 threaded hole 5 mm deep & 4 M2.5 threaded holes on 0 15 mm 4 mm deep 2 PTFE insulated AWG26 wires 100 mm long with 0 1 banana plug > PROPERTIES STANDARD TECHNICAL CONDITIONS OF USE AND MEASUREMENT Free-free : Blocked-free : Quasistatic excitation : Harmonic excitation : Max. harmonic excitation : Displacement measurement : Admittance measurement : Environment : The actuator is not fixed The actuator is fixed to a mechanical support assumed infinitely stiff AC voltage between -20 and 150 V at 1 Hz Voltage of 0.5 Vrms, sinusoidal mode from 0 to 100 kHz Voltage defined by the measurement of max. displacement, sinus at resonance frequency Laser interferometer, capacitive displacement sensor HP 4194 A or Cypher C60 electrical impedance analyser Ambient temperature (15-25°C) and dry air (Humidity < 50 % rH) Any technical conditions of use, different from those defined above, can lead to temporary or definitive alterations of properties. Thank you to contact CEDRAT TECHNOLOGIES before using actuators under non standard technical conditions. > FACTORY TESTS CARRIED OUT 0 Test 1 : Electrical admittance vs. Frequency, free-free 0 Test 2 : Displacement vs. input voltage > OPTIONAL EXTRA FACTORY TESTS 0 Test 3 : Gain and linearity of the sensor 0 Test 4 : Step response in closed loop 0 Test 5 : Stability in closed loop > OPTIONAL MECHANICAL INTERFACE □ [ FI ] Flat Interface □ [ H ] Flat Interface with hole 0 [ TH ] Flat Interface with threaded hole □ [ FF ] Free-free Interface 0 [ SI ] Specific interface > AVAILABLE OPTIONS 0 [ SG ] Strain gauges □ [ NM ] Non-magnetic □ [ ECS ] Eddy current displacement sensor 0 [ VAC ] Vacuum 0 [ SV ] Specific version / Customization

 Open the catalog to page 1
PPA40L-2

^ CEDRAT v , TECHNOLOGIES \ | Innovation in Mechatronics

 Open the catalog to page 2

All CEDRAT TECHNOLOGIES catalogs and technical brochures

  1. DTT35XS-SI-2

    3  Pages

  2. DTT35XS

    3  Pages

  3. TT60SM

    3  Pages

  4. APA600M

    2  Pages

  5. APA400M

    2  Pages

  6. APA200M

    2  Pages

  7. APA150M

    2  Pages

  8. APA100M

    2  Pages

  9. APA60SM

    2  Pages

  10. APA40SM

    2  Pages

  11. APA60S

    2  Pages

  12. APA50XS

    2  Pages

  13. APA35XS

    2  Pages

  14. APA150XXS

    2  Pages

  15. PPA20M

    2  Pages

  16. PPA40M

    2  Pages

  17. PPA60L

    2  Pages

  18. PPA80L

    2  Pages

  19. PPA120L

    2  Pages

  20. PPA40XL

    2  Pages

  21. PPA80XL

    2  Pages

  22. RK42F3U-LC75B

    2  Pages

  23. CA45

    4  Pages

  24. LA75A

    4  Pages

  25. LA75B

    4  Pages

  26. LA75C

    3  Pages

  27. SA75A

    3  Pages

  28. SA75B

    3  Pages

  29. SA75D

    3  Pages

  30. SP75A

    3  Pages

  31. UC65

    3  Pages

  32. UC55

    3  Pages

  33. UC45

    2  Pages

  34. RK42F3U-LC24

    2  Pages

  35. ECSU10

    2  Pages

  36. ECS75

    3  Pages

  37. ECP1000

    2  Pages

  38. ECP500

    2  Pages

  39. XY25XS

    2  Pages

  40. APA30uXS

    2  Pages

  41. PPA10M

    2  Pages

  42. MISAC PROJECT

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.