APA60SM

APA60SM

APA60SM

Product catalog summary
Standard Properties and Technical Conditions:
The document outlines the standard properties and technical conditions for the APA60SM actuator. It specifies that the properties are guaranteed within their variation range under standard technical conditions of use, which include ambient temperature (15-25°C) and dry air (humidity < 50% rH). Deviations from these conditions may alter the actuator's properties.

Factory Tests:
Several factory tests are conducted to ensure the actuator's performance, including electrical admittance vs. frequency, displacement vs. input voltage, gain and linearity of the sensor, step response in closed loop, and stability in closed loop.

Optional Mechanical Interface and Available Options:
The document lists optional mechanical interfaces such as flat interfaces with or without holes, specific interfaces, and options like strain gauges, non-magnetic versions, and vacuum compatibility.

Technical Specifications:
The document provides detailed specifications including:
  • Max. no load displacement: 82 µm (nominal), with a range of 65-96 µm.
  • Blocked force: 105 N (nominal), with a range of 84-126 N.
  • Stiffness: 1.287 N/µm (nominal), with a range of 1.030-1.42 N/µm.
  • Resonance frequency (free-free): 10235 Hz (nominal), with a range of 8700-11259 Hz.
  • Response time (free-free): 0.05 ms (nominal), with a range of 0.04-0.06 ms.
  • Capacitance: 1.55 µF (nominal), with a range of 1.40-2.02 µF.

Physical Dimensions:
The actuator's dimensions are specified as height 13 mm, length 26.9 mm, width excluding wedge and wires 10 mm, and including wedge and wires 11.5 mm. The mass is 10 g.

Interfaces:
The standard mechanical interface consists of two flat surfaces with a 5x10 mm² area and an M2.5 threaded hole. The electrical interface includes two PTFE insulated AWG30 wires, 100 mm long, with a Ø 1 banana plug.
See more

Catalog excerpts

APA60SM-1

copyright © cedrat technologies | 02/2014 www.cedrat-technologies.com | [email protected] ^ CEDRAT < , TECHNOLOGIES\ \ Innovation in Mechatronics > TABLE OF STANDARD PROPERTIES OF USE AND MEASUREMENT The properties defined in the table below, are set up according to the technical conditions of use and measurement. These properties are warranted within their variation range and in compliance with the standard technical conditions of use. STANDARD TECHNICAL CONDITIONS Notes Max. no load displacement Blocked force Stiffness Resonance frequency (free-free) Response time (free-free) Resonance frequency (blocked-free) Response time (blocked-free) Capacitance Max. no load displacement at resonance Max. voltage at resonance Force limit (0-pk) Resolution Height (in actuation direction) Length Width (excl. wedge & wires) Width (incl. wedge & wires) Mass Standard mechanical interface Standard electrical interface Quasistatic excitation, blocked-free Quasistatic excitation, blocked-free Quasistatic excitation, blocked-free Harmonic excitation, free-free, on the admittance curve Harmonic excitation, blocked-free, on the admittance curve Quasistatic excitation, free-free, on the admittance curve Max. harmonic excitation, free-free Max. harmonic excitation, free-free Max. harmonic excitation, free-free Quasistatic excitation 2 flat surfaces 5*10 mm2 with M2.5 threaded hole 2 PTFE insulated AWG30 wires 100 mm long with 0 1 banana plug > PROPERTIES STANDARD TECHNICAL CONDITIONS OF USE AND MEASUREMENT Free-free : Blocked-free : Quasistatic excitation : Harmonic excitation : Max. harmonic excitation : Displacement measurement : Admittance measurement : Environment : The actuator is not fixed The actuator is fixed to a mechanical support assumed infinitely stiff AC voltage between -20 and 150 V at 1 Hz Voltage of 0.5 Vrms, sinusoidal mode from 0 to 100 kHz Voltage defined by the measurement of max. displacement, sinus at resonance frequency Laser interferometer, capacitive displacement sensor HP 4194 A or Cypher C60 electrical impedance analyser Ambient temperature (15-25°C) and dry air (Humidity < 50 % rH) Any technical conditions of use, different from those defined above, can lead to temporary or definitive alterations of properties. Thank you to contact CEDRAT TECHNOLOGIES before using actuators under non standard technical conditions. > FACTORY TESTS CARRIED OUT 0 Test 1 : Electrical admittance vs. Frequency, free-free 0 Test 2 : Displacement vs. input voltage > OPTIONAL EXTRA FACTORY TESTS 0 Test 3 : Gain and linearity of the sensor 0 Test 4 : Step response in closed loop 0 Test 5 : Stability in closed loop > OPTIONAL MECHANICAL INTERFACE 0 [ FI ] Flat Interface 0 [ H ] Flat Interface with hole 0 [ TH ] Flat Interface with threaded hole □ [ FF ] Free-free Interface 0 [ SI ] Specific interface > AVAILABLE OPTIONS 0 [ SG ] Strain gauges 0 [ NM ] Non-magnetic □ [ ECS ] Eddy current displacement sensor 0 [ VAC ] Vacuum 0 [ SV ] Specific version / customization

 Open the catalog to page 1
APA60SM-2

copyright © cedrat technologies | 02/2014 www.cedrat-technologies.com | [email protected] ^ CEDRAT v , TECHNOLOGIES \ | Innovation in Mechatronics

 Open the catalog to page 2

All CEDRAT TECHNOLOGIES catalogs and technical brochures

  1. DTT35XS-SI-2

    3  Pages

  2. DTT35XS

    3  Pages

  3. TT60SM

    3  Pages

  4. APA600M

    2  Pages

  5. APA400M

    2  Pages

  6. APA200M

    2  Pages

  7. APA150M

    2  Pages

  8. APA100M

    2  Pages

  9. APA40SM

    2  Pages

  10. APA60S

    2  Pages

  11. APA50XS

    2  Pages

  12. APA35XS

    2  Pages

  13. APA150XXS

    2  Pages

  14. PPA20M

    2  Pages

  15. PPA40M

    2  Pages

  16. PPA40L

    2  Pages

  17. PPA60L

    2  Pages

  18. PPA80L

    2  Pages

  19. PPA120L

    2  Pages

  20. PPA40XL

    2  Pages

  21. PPA80XL

    2  Pages

  22. RK42F3U-LC75B

    2  Pages

  23. CA45

    4  Pages

  24. LA75A

    4  Pages

  25. LA75B

    4  Pages

  26. LA75C

    3  Pages

  27. SA75A

    3  Pages

  28. SA75B

    3  Pages

  29. SA75D

    3  Pages

  30. SP75A

    3  Pages

  31. UC65

    3  Pages

  32. UC55

    3  Pages

  33. UC45

    2  Pages

  34. RK42F3U-LC24

    2  Pages

  35. ECSU10

    2  Pages

  36. ECS75

    3  Pages

  37. ECP1000

    2  Pages

  38. ECP500

    2  Pages

  39. XY25XS

    2  Pages

  40. APA30uXS

    2  Pages

  41. PPA10M

    2  Pages

  42. MISAC PROJECT

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.