1. Catalogs
  2. CEC Vibration Products
  3. Vibration Transducer 4-131

Vibration Transducer 4-131

Vibration Transducer 4-131

Vibration Transducer 4-131

Product catalog summary
Applications
  • Industrial Turbines
  • Turbine-Driven Machinery
  • Power Generators
  • Gas Pumping Systems
Features
  • Friction-free design for extended lifespan
  • Self-generated, high-level, low impedance output
  • Operates up to +700°F, with +900°F versions available
Description

The CEC 4-131 Vibration Transducers are designed for industrial applications, particularly in high-temperature turbine sections. The friction-free moving elements ensure long life and reliability, making them suitable for environments where other transducers may fail. The low impedance, high-level output simplifies system integration by eliminating the need for special amplifiers.

The transducers measure low vibration levels, crucial for precision-balanced turbine systems, with limitations only due to system noise. They operate using a seismic mass magnet suspended by springs and a coil attached to the case, producing an output signal proportional to velocity. The sealed case protects the instrument in harsh environments.

Performance Specifications
  • Sensitivity: Varies by model, refer to Table 1
  • Dynamic Range: Frequency 15 Hz to 2000 Hz, Amplitude 0.07 inch peak-to-peak, Acceleration 0.2 g to 50 g
  • Temperature Range: -65°F to +700°F, with +900°F available on special order
  • Linearity: ±6% between 0.1 & 1.0 ips at 80 Hz & 77°F
  • Frequency Response: ±15% of reference sensitivity
  • Shock Resistance: 50 g’s maximum
Approvals
  • North American: Intrinsically Safe Class I, Division 1, Groups A, B, C & D
  • European: EEx ia IIB or IIC T1...T6
Ordering Information

Specifications may change without notice. Optional accessories include cable and connector assemblies.

Table 1: Part Number and Sensitivity
  • 4-131-0001: 135 mV, Max Temp +700°F
  • 4-131-0103: 150 mV, Max Temp +700°F
  • 4-131-0107: 145 mV, Max Temp +700°F
  • 4-131-0116: 200 mV, Max Temp +700°F
  • 4-131-0123: 135 mV, Max Temp +900°F
See more

Catalog excerpts

Vibration Transducer 4-131-1

4-131 Applications • Industrial Turbines • Turbine-Driven Machinery • Power Generators • Gas Pumping Systems Features • Friction-free design for long life • Self-generated, high level, low impedance output • Operates to +700°F (+900°F versions are available) Description The friction-free moving elements in CEC’s 4-131 Vibration Transducers assure long life and reliability. Designed for industrial applications on fixed turbines, you can use this instrument in turbine hot sections where high temperatures cause problems with other transducers. The system is simplified due to the low impedence, high level output that can drive AC meters, recorders, and control electronics without using special amplifiers. The frictionless design also allows measurement of extremely low vibration levels, critical when monitoring precision balanced turbine systems. The low level is limited only by system noise. These transducers use a seismic mass magnet suspended by springs and a coil attached to the case. The output signal results from relative movement between the magnet and coil when the case vibrates. The air damped system operates above its natural frequency, so the output signal is proportional to velocity. The sealed case prevents damage to the instrument when used in difficult environments. CEC Vibration Products • 746 Arrow Grand Circle • Covina, California 91722 • USA (626) 938-0200 • (800) 468-1345 • Fax: (626) 938-0202 www.cecvp.com ISO 9001:2000 AS9100 Certified Velocity Sensors Vibration Transducer

 Open the catalog to page 1
Vibration Transducer 4-131-2

4-131 Vibration Transducer Performance Specifications Table 1 (refer to table 1) mV/in/sec ±3% at 80 Hz and +77°F (+25°C) ±4°F at 0.5 in/sec (ips), load impedance is 10,000 Ω ±2% Dynamic Range Part Number Sensitivity Max Temp 4-131-0001 135 mV +700°F (+371°C) 4-131-0103 150 mV +700°F (+371°C) 4-131-0107 Sensitivity: 145 mV +700°F (+371°C) Frequency: 15 Hz to 2000 Hz 4-131-0116 200 mV +700°F (+371°C) Amplitude: 0.07 inch peak-to-peak, maximum 4-131-0123 135 mV +900°F (+482°C) Acceleration: 0.2 g to 50 g Acceleration Threshold: 0.01 g peak Linearity: ±6% along straight line between 0.1 & 1.0 ips...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.