N30P DIGITAL PANEL METER-1

N30P DIGITAL PANEL METER • Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cos, tg, , frequency, active, reactive and apparent energy, 15 minutes’ active power, 10 minutes’ voltage, 10 seconds’ frequency. • Three-colour display (14 mm high), in three intervals of the measured value. • Meter programming from the keyboard or through the RS-485 interface by means of the free delivered LPConfig program. • Four alarm outputs with signalling by LED diodes, operating in 6 different modes. • Storage of minimal and maximal values for all measured quantities. • Conversion of any measured value into a 0/4...20 mA or 0...10 V analog signal. • Storage of minimal and maximal values for all measured quantities. • Firmware updating (option). FeATUReS: LPConfig Program Example of Application KD7 recorder INPUTS: N30P digital meter PC Computer/ configuration by LPConfig program Measurement and recording of energy consumption in 1-phase or three-phase symmetrically loaded network Inputs Input kind Voltage input Current input Measuring range Rated operating conditions Ratio values Measuring Ranges Input kind GAlVANIC ISolATIoN: Indication range Measuring range Basic error Current 1 A/5 A Voltage 100 V/400 V Frequency Active power Reactive power Apparent power Cos φ Tangens φ φ Active energy Reactive energy Current time Output kind Relay output Analog output Properties • 2 x relays, voltageless NO contacts, load-carrying capacity 250 V a.c./ 0.5 A a.c. • 2 x relays, voltageless change-over contacts, load-carrying capacity 250 V a.c./ 0.5 A a.c. • current programmable 0/4...20 mA, load resistance ≤ 500 Ω • voltage programmable 0...10 V, load resistance ≥ 500 Ω • resolution 0.01% of the range Energy pulse output • OC type output, passive of class A, acc. to EN 62053-31, supply voltage 18...27 V, current 10...27 mA. • Output pulse constant: 5000 imp./kWh, independently of Ku and Ki settings. Transmission protocol MODBUS RTU Digital Interfaces

 Open the catalog to page 1
N30P DIGITAL PANEL METER-2

N30P DIGITAL PANEL METER External Features 5 digit LED display indication range -19999..99999 digit height: 14 mm < 0.2 kg Readout field Weight Overall dimensions 96 ´ 48 ´ 93 mm from frontal side: IP65 three-colour display (colour changes depending on displayed value): red, green, orange Panel cut-out: 92+0,6 ´ 45+0,6 mm from rear side: IP 10 Rated Operating Conditions Supply voltage Temperature Relative humidity Operating position External magnetic field Short duration overload (5 s) Power consumption: - in supply circuit - in voltage/current circuit storage: -30...70°C condensation inadmissible...

 Open the catalog to page 2

All CD Automation UK Ltd catalogs and technical brochures

  1. SOFT STARTER

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.