1. Catalogs
  2. CCI Thermal Technologies Inc.
  3. Air and Space Heaters Section C

Air and Space Heaters Section C

Air and Space Heaters Section C
1 / 40 PagesView full catalog

Air and Space Heaters Section C

Product catalog summary
Overview: This document provides comprehensive details on various air and space heaters by Caloritech™, a brand under CCI Thermal Technologies Inc. It covers specifications, applications, and installation guidelines for different heater models.
1. Air Duct Heaters: Models DFF, DIF, DFT, and DIT are designed for air duct systems, offering efficient heating solutions.
2. Control Panel & Pump House Heater (PXFT): These heaters maintain stable temperatures in control enclosures and pump houses, featuring a high surface area aluminum heat emitter and adjustable thermostat. Proper mounting is crucial for optimal performance.
3. Corrosion-Resistant Washdown Unit Heaters (CCR1 Triton™): Designed for environments requiring corrosion resistance, ensuring durability and reliability.
4. Explosion-Proof Duct Heaters (XDF): Suitable for hazardous environments, these heaters include safety features to prevent explosions.
5. Fan-Forced Enclosure Heater (PH): Used to control the environment within enclosures, preventing corrosion and condensation. The document provides a method for calculating the required wattage based on enclosure size and temperature difference.
6. Forced Air Heaters: Available in heavy-duty (GX) and regular-duty (GE) models for robust industrial applications.
7. Infrared Radiant Heaters: Includes models for comfort and process heating, such as the OKB, OKH, OKD, OK3, and OKA series. Portable options (OKP series) are available for comfort heating.
8. Process Duct Heaters (WX): Designed for industrial processes requiring precise temperature control.
9. Reference and Warranty: Includes a reference section for catalogues and warranty information, ensuring customer satisfaction and product reliability.
Conclusion: CCI Thermal Technologies Inc. emphasizes safety, quality, and customer service, offering a wide range of heating solutions tailored to various industrial needs. Proper installation and selection are crucial for optimal performance and efficiency.
Caloritech™ BX Convection Heaters: Designed for industrial settings like factory offices and crane cabs, featuring stainless steel sheathed heating elements and a 14-gauge steel enclosure. Available with or without built-in thermostats.
Caloritech™ Air Duct Heaters (DFF, DIF, DFT & DIT): Used in comfort heating applications with optional controls like thermostats and switches. Finned tubular elements are popular for efficiency, while Incoloy® elements offer corrosion resistance.
Caloritech™ Explosion-Proof Duct Heaters (XDF): Designed for hazardous environments with heavy walled carbon steel finned tubular elements and unique terminal housing for easy access.
Heater Specifications: Various duct sizes, heating banks, power ratings, and available voltages are detailed. Control panels include moisture-resistant or explosion-proof types with standard features like magnetic contactors and high limit controls.
Specifications and Features: Caloritech™ infrared heaters are available in various fixtures with metal sheathed, quartz tube, or quartz lamp heating elements. Control options include percentage timers and thermostatic control.
Additional Products: Caloritech™ offers GE and GX series forced air heaters for industrial and commercial applications, featuring adjustable air flow louvers and overheat protection.
Specifications and Features: The CCR1 Triton™ heaters are available in various models with power ratings from 3 kW to 39 kW, featuring a NEMA Type 4X non-metallic enclosure and stainless steel heating elements. They comply with UL and U.S. Coast Guard regulations.
Warranty: An 18-month warranty from the date of shipment or 12 months from the start date of use covers defects in material or workmanship, with exclusions for improper use or installation.
See more

Catalog excerpts

Air and Space Heaters Section C-1

Heating and Filtration Solutions Engineered Electric Heat

 Open the catalog to page 1
Air and Space Heaters Section C-2

Contents Air Duct Heaters Control Panel & Pump House Heater Corrosion-Resistant Washdown Unit Heaters Explosion-Proof Duct Heaters Fan-Forced Enclosure Heater Forced Air Heaters - Heavy Duty Forced Air Heaters - Regular Duty Gain & Gate Heaters Heavy Duty Convection Heater Infrared Radiant Heaters Infrared Radiant Heaters - Comfort Heating Infrared Radiant Heaters - Process Heating Portable Radiant Heaters - Comfort Heating Process Duct Heaters Index Reference

 Open the catalog to page 2
Air and Space Heaters Section C-3

Edmonton, Alberta Houston, Texas Orillia, Ontario Greensburg, Indiana Oakville, Ontario Denver, Colorado As a leader in heating and filtration solutions, CCI Thermal Technologies Inc. is committed to ongoing research, product development and above all, excellence in customer service. With facilities across North America, CCI Thermal manufactures six of the top brands in industrial heating in addition to a comprehensive line of engineered industrial filtration products including: Cata-Dyne™ Explosion-Proof Gas Catalytic Heaters Ruffneck™ Heaters for the Harshest Environments Caloritech™ Engineered...

 Open the catalog to page 3
Air and Space Heaters Section C-4

Caloritech™ Catalog: Section A Caloritech™ Catalog: Section D Calvane™ heaters, tubular heaters, bolt heaters, tubular band heaters, mitosis heaters, finned tubular heaters, cartridge heaters, strip and finned strip heaters, hot plate/drum heaters, castin heaters, transit heaters. circulation heaters, heat transfer systems, custom engineered products, panel heaters, control panels, technical data. Elements and Specialty Heaters Engineered Products ers ty Heat A Special Section Caloritech™ Catalog: Section B Caloritech™ Catalog: Section E screwplug heaters, domestic immersion heaters, urn heaters,...

 Open the catalog to page 4
Air and Space Heaters Section C-5

Cata-Dyne™ Catalog Fastrax® Catalog explosion-proof infrared gas catalytic heaters, high temperature industrial infrared heaters, infrared gas catalytic heating systems, accessories. track and switch heaters, custom designed automated control systems, accessories. ers oof ic Heat sion-Pr s Catalyt Ga Ruffneck™ Catalog DriQuik™ Catalog explosion-proof electric air heaters, heat-exchanger unit heaters, corrosion-resistant washdown unit heaters, convection heaters, thermostats. long, medium and short wavelength infrared ovens and emitters, dusters, cooling tunnels, control panels. filters, strainers,...

 Open the catalog to page 5
Air and Space Heaters Section C-6

Fan-Forced Enclosure Heater - PHDifference TABLE 1 - Temperature Caloritech™ PH fan-forced enclosure heaters are designed to control the environment within enclosures by maintaining a stable temperature. Effects of low temperatures such as corrosion, freezing or condensation will adversely affect the components inside control panels. The Caloritech™ PH enclosure heater will provide an optimal performance environment for the critical components contained within the control panel. Uninsulated Insulated (Min. 1”/25 mm) Watts/m2 Per 5.5C° Uninsulated Insulated (Min. 2.5 cm) Example: To find wattage...

 Open the catalog to page 6
Air and Space Heaters Section C-7

Control Panel & Pump House Heater - PXFT Application TABLE 1 - Temperature Difference Caloritech™ PXFT heaters are designed to maintain a stable temperature inside control enclosures, pump houses or similar spaces. The standard units are not suitable for use outdoors, unprotected from the weather. All heaters have a built-in thermostat. The heater is also available without a thermostat on special order. Watts/ft2 Per 10F° Uninsulated Insulated (Min. 1”) Watts/m2 Per 5.5C° Uninsulated Insulated (Min. 2.5 cm) Example: To find wattage requirements in an uninsulated enclosure 2’ x 3’ x 1/2’ (0.61...

 Open the catalog to page 7
Air and Space Heaters Section C-8

Heavy Duty Convection Heater - BX Installation Caloritech™ BX convection heaters are ideally suited for industrial applications where rugged and dependable units are required. Typical installations include: • factory offices • crane cabs • ticket booths • guard houses • repair shops • shipping rooms • trains and streetcars In addition to the reversible terminal enclosure, as a further convenience, heaters include combination brackets (shipped separately) suitable for wall or floor mounting. When installed, heaters must be spaced not less than 3.625” (92 mm) from floor or wall. Use supply wires...

 Open the catalog to page 8
Air and Space Heaters Section C-9

Air Duct Heaters - DFF, DIF, DFT & DIT Application Optional Auxiliary Duct Heater Controls Caloritech™ air duct heaters are for use in comfort heating applications. Typical applications include: • make-up air heating • air pre-heating • air handling equipment • fan coils • terminal reheating • multizone reheating • heat pump auxiliary systems • return air heating These controls are available as factory installed on the duct heater or as an Electrical & Electronic Manufacturing Association (EEMAC) rated (specify) control panel for wall mount: • wall thermostats • differential pressure switch T498AT6051A...

 Open the catalog to page 9
Air and Space Heaters Section C-10

Wiring and Auxiliary Controls Figure 2 – Tubular Element Incoloy® tubular elements are similarly constructed, but without the steel fin in order to increase the corrosion resistance. The Incoloy® design should be chosen where high humidity or slightly corrosive chemical contaminants are present in the air stream. These units are made and approved on special order only. Both element types are designed to provide many years of maintenance free service. Unlike open coil designs, duct heaters fitted with tubular elements are not subject to hazards of electrical shock which allows installation close...

 Open the catalog to page 10
Air and Space Heaters Section C-11

Standard Dimensions Insert type duct heaters are slightly undersized to permit installation in ducts having the A and B dimensions listed in Table 1. DERATING FACTOR VELOCITY (FT/MIN) Figure 7 – Derating Factors Selection and Installation Finned tubular duct heaters are approved for horizontal duct installation where the maximum inlet air temperature does not exceed 77°F (25°C) and the maximum rating does not exceed 120 kW. Multiple heaters can be installed in tandem (series provided that the inlet temperature to any heater section one heater) is not more than 77°F (25°C) and the air velocity...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.