QF(18) - Series Miniature Circuit Breakers
8Pages

{{requestButtons}}

Catalog excerpts

QF(18) - Series Miniature Circuit Breakers - 1

QF(18) - Series Miniature Circuit Breakers AC circuit breaker Hydraulic-magnetic technology 100% rating capability, independent of ambient temperature One, two, three pole, 1+N and 3+N VC 8036 compliant (SANS 556-1) VDE, EAC and CCC approved, CE certified UL 1077 recognised (supplementary protector) Ratings 1 A to 63 A Optional shunt trip (IEC / EN 60947-2) Wide range of time delays & operating currents Precision tripping characteristics Trip indication with mid-trip position Can be switched on immediately after tripping DIN mount product in grey shells Suitable to use for electrical isolation AC branch circuit protection (IEC / EN 60947-2) Supplementary protection (UL 1077) Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Railway signalling equipment Residential equipment Industrial equipment Auxiliary Switch: Features Optional Accessories Factory fitted Attached to right hand side of the circuit breaker Compact 6.5 mm width UL 489 listed & IEC 60947-5-1 110 Vdc, 0.5 A; 240 Vac, 6A Handle lock Surface mounting clips Busbar Hydraulic-Magnetic Circuit Breakers 100% rated, unaffected by ambient temperature QF18-SE

Open the catalog to page 1
QF(18) - Series Miniature Circuit Breakers - 2

QF(18) - Series Miniature Circuit BreakersTechnical Data Product Type Auxiliary Module

Open the catalog to page 2
QF(18) - Series Miniature Circuit Breakers - 3

QF(18) - Series Miniature Circuit BreakersTechnical Data Product Type * Refer to standard for details.

Open the catalog to page 3
QF(18) - Series Miniature Circuit Breakers - 4

QF(18) - Series Miniature Circuit Breakers Long Code Switch / neutral Auxiliary switch Triple pole Medium delay curve 2 Shunt trip Long Code Ordering Information For options not listed, please contact CBI

Open the catalog to page 4
QF(18) - Series Miniature Circuit Breakers - 5

QF(18) - Series Miniature Circuit Breakers Time Delay Curves Tripping Time (Seconds) % Rated Current Data Sheet Page 5 of 8

Open the catalog to page 5
QF(18) - Series Miniature Circuit Breakers - 6

QF(18) - Series Miniature Circuit Breakers Time Delay Curves Tripping Time (Seconds) % Rated Current Data Sheet Page 6 of 8

Open the catalog to page 6
QF(18) - Series Miniature Circuit Breakers - 7

QF(18) - Series Miniature Circuit Breakers Time Delay Curves 1500 Tripping Time (Seconds) % Rated Current * The published time delay curves are generated at 25oC ambient temperature with the circuit breaker mounted in the up-right position. The “must hold”, “must trip” and “instantaneous trip” current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. Internal Impedance vs Current Rating Q-Range impedance values Data Sheet

Open the catalog to page 7
QF(18) - Series Miniature Circuit Breakers - 8

QF(18) - Series Miniature Circuit BreakersOutline Dimensions: DIN Mount TOLERANCES ±0.4 UNLESS OTHERWISE STATED (DIMENSIONS IN BRAKETS ARE IN INCHES) Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for...

Open the catalog to page 8

All CBI-electric: low voltage catalogs and technical brochures

  1. GLOBAL RANGE