GLOBAL RANGE

GLOBAL RANGE
1 / 26 PagesView full catalog

GLOBAL RANGE

Product catalog summary
Air Circuit Breakers (ACB) Catalogue Overview
This document provides a comprehensive overview of low voltage Air Circuit Breakers (ACB), detailing specifications, accessories, and operational guidelines.
ACB Product Overview
The catalogue lists ACB models with current ratings from 630A to 4000A, available in fixed and draw-out configurations, with isolator options. Customization is possible with standard and optional accessories.
ACB Product Specifications
Specifications cover rated insulation voltage, impulse withstand voltage, breaking capacity, and operating voltage. ACBs operate at 50/60 Hz and come in 3 or 4 pole configurations. Details on mechanical and electrical life cycles, connection types, and dimensions are provided.
ACB Accessories Overview
Accessories include shunt coils, closing coils, motor charges, under voltage trip devices, and various switches and locks, enhancing functionality and safety.
Over Current Relay (OCR)
The OCR offers overload, short-circuit, and ground fault protection, with a high-speed MCU for accurate measurements and fault recording. Communication options include Modbus and Profibus-DP.
ACB Wiring Diagram
Wiring diagrams show internal and external connections, including auxiliary switches, motor charging, and shunt tripping devices, emphasizing correct RS-485 polarity for communication.
Protection Features
Features include long-time, short-time, and instantaneous tripping settings, with optional I2t settings for enhanced coordination. Ground fault protection is available with optional ZCT or external CT.
Characteristic Curves
Characteristic curves illustrate ACB performance under various conditions.
Certifications and Standards
ACBs comply with IEC 60947-2 standards and are DEKRA certified, ensuring reliability and safety.
Specifications
Key parameters include current settings (Iu, Ir, Isd, Ii, Ig), time delays (tr, tsd, tg), and accuracy levels. Current settings for long-time, short-time, instantaneous, and ground fault protections are specified with accuracy tolerances.
Procedures
Detailed procedures for setting up and operating ACBs are provided, including wiring diagrams for shunt coils, closing coils, and under voltage trip devices. Operating voltage ranges and power consumption are specified.
Norms and Standards
References to IEC 60947 for operating voltage ranges, dielectric strength, and endurance cycles are included, along with guidelines for using auxiliary switches to monitor ACB's ON/OFF position remotely.
Recommendations
Recommendations include ensuring correct voltage range for UVT coil to prevent closure issues and using time-delay devices with UVT for effective trip management.
Dimensional Drawings
Dimensional drawings for various ACB configurations, including fixed and draw-out types, and horizontal and vertical orientations, are provided for different current ratings.
Characteristic Curves
Characteristic curves for long-time, short-time, instantaneous, and ground fault protections illustrate tripping characteristics under different conditions.
Accessories
Details on ACB accessories such as shunt coils, closing coils, and auxiliary switches are included, with specifications for rated voltage, power consumption, and wiring requirements.
See more

Catalog excerpts

GLOBAL RANGE-2

OCR - Over Current Relay Characteristic Curves Global Range Air Circuit Breakers

 Open the catalog to page 2
GLOBAL RANGE-3

ACB Product Overview Product Line up Circuit Breaker Global Range Air Circuit Breakers Accessories Standard Standard (pre-fitted) Isolator Fixed Closing Coil Advanced Control Module Motor Charge Counter Frame Door Cradle Lifting Hooks AG5** C Overload protection C Short-circuit protection C Ground fault protection C Realization of protective coordination by ZSI C High-performance and high-speed MCU built-in C Fault recording C SBO (Select Before Operation) C 3 DO (Digital Output) C Communication Accessories Optional AC / DC Optional Motor Charge Closing Coil Isolator Fixed Advanced Control Module...

 Open the catalog to page 3
GLOBAL RANGE-4

ACB Product Specifications Type Ampere Frame Rated Current of Neutral Pole (A) 4P%* (Ui) Rated Operating Voltage (V) Global Range Air Circuit Breakers Rated Insulation Voltage (V) Rated Impulse Withstand Voltage (Uimp) Rated Breaking Capacity (kA sym) Maximum Total Breaking Time Maximum Closing Time Rated Service Breaking Capacity (kA) Rated Making Capacity (kA peak) IEC 60947-2 AC 50 / 60 Hz Rated Short-time Withstand Current (kA) (Icw) Operating Time (ms) Life Cycle Draw-out / Fixed Electrical Connections Horizontal Connection *Vertical Connection *Front Connection *Mixed Connection Draw-out...

 Open the catalog to page 4
GLOBAL RANGE-5

ACB Product Specifications Type Type Ampere Frame Rated Current (A) Rated Current of Neutral Nole (A) Rated Operating Voltage (V) Global Range Air Circuit Breakers Rated Insulation Voltage (V) Rated Impulse Withstand Voltage (Uimp) Rated Breaking Capacity (kA sym) AC 50 / 60 Hz Rated Service Breaking Capacity (kA) Rated Making Capacity (kA peak) Maximum Total Breaking Time Maximum Closing Time Rated Short-time Withstand Current (kA)** (Icw) Operating Time (ms) Life Cycle Mechanical Electrical Draw-out / Fixed Horizontal Connection *Vertical connection *Front connection *Mixed connection Weight...

 Open the catalog to page 5
GLOBAL RANGE-6

Standard Option Mounting SHT2 Double Shunt Coil Standard Option Voltage Module Charge Switch Closing Coil Charge Switch Communication Under Voltage Trip Device Trip relay Trip Alarm Contact Mechanical Interlock Manual Reset Button Safety Shutter (Draw out only) Remote Reset Switch Safety Shutter Lock Ready to Close Switch Miss Insertion Prevent Device MOC Mechanical Operated Cell Switch Temperature Alarm Cell Switch Door Interlock Safety Control Cover Body Supporter On/Off Button lock Racking Interlock Pad Lock/ Position Lock Insulation Barrier Lifting Hook Condenser Trip Device Automatic Transfer...

 Open the catalog to page 6
GLOBAL RANGE-7

Measurement Element Phase Voltage Normal Voltage Global Range Air Circuit Breakers Reverse Voltage Line Voltage Normal Current Reverse Current Display Range Line Current Detailed Element VabIa, VabIb, Active Power Reactive Power Qa(ab), Qb(bc), Qc(ca), Q Apparent Power Pa(ab), Pb(bc), Pc(ca), P Sa(ab), Sb(bc), Sc(ca), S WHa(ab), WHb(bc), Active Energy rWHa(ab), rWHb(bc), Energy Freq. Power factor Reverse Active Frequency Power Factor (PF) Unbalance Rate Reactive Energy Active Power PFa(ab), PFb(bc), PFc(ca), PF % Peak demand Current Harmonics 1st ~ 63th harmonics of Ia,Ib,Ic Peak demand Current...

 Open the catalog to page 7
GLOBAL RANGE-8

OCR: Over Current Relay A Type: Over Current Relay Fault recording - Records Max. up to 10 fault information about fault type, fault phase, fault data, occurrence time of fault SBO (Select Before Operation) - High reliability for control and setting change method 3 DO (Digital Output) - Fixed Communication - Modbus / RS485 - Profibus-DP LCD: Indication of measurement and information LED: Indication of trip info. and overload state Ig: LED indicating ground-fault Isd/Ii: LED indicating short-time or instantaneous tripping Ir: LED indicating long-time delay SP: Self-protection and battery test LED...

 Open the catalog to page 8
GLOBAL RANGE-9

Global Range Air Circuit Breakers This diagram is based on “CONNECTED” position of a Circuit Breaker and opening, Motor charging and releasing of locking should be normal condition. Terminal Code Description Auxiliary switch “a” Voltage input terminal of UVT Charged signal Charged signal communication Ready to close switch Motor charging Control power Closing coil Alarm contact Shunt trip Alarm reset (Trip cause LED, Alarm contact) Note) 1 The diagram is shown with circuits de-energized, all devices open, connected and charged and relays in normal position 1 Relay is normal condition and charging...

 Open the catalog to page 9
GLOBAL RANGE-10

Global Range Air Circuit Breakers Accessory code description Z1 Temperature module Position switch Auxiliary switch Internal wiring Long time delay trip indicator Short time delay/instantaneous External wiring (by customer) Ground fault trip indicator Cell switch circuit terminal of drawout type Closing coil Shunt tripping device 1 Shunt tripping device 2

 Open the catalog to page 10
GLOBAL RANGE-11

Protection Long Time Global Range Air Circuit Breakers Short time Current Setting (A) Accuracy: ± 10% Time Delay (s) Time (ms) Max. Trip Time (ms) Current Setting (A) Tripping Time Ground fault Earth Leakage (Option) Timed Delay (ms) Accuracy: ± 15% Time (ms) Trip Time (ms) Note: Earth leakage function is available with ZCT or e

 Open the catalog to page 11
GLOBAL RANGE-12

ACB Dimensional Drawings ACB 630 - 1600 A CMF Type Fixed ACB 630 - 1600 A CMD Horizontal Type Draw out Global Range Air Circuit Breakers

 Open the catalog to page 12
GLOBAL RANGE-13

Global Range Air Circuit Breakers ACB 2000 A CMF Vertical Type Fixed ACB 2000 A CMD Vertical Type Draw-out

 Open the catalog to page 13
GLOBAL RANGE-14

ACB Dimensional Drawings ACB 2500 - 3200 A CMF Horizontal Type Fixed Global Range Air Circuit Breakers ACB 2500 - 3200 A CMF Horizontal Type Draw-out

 Open the catalog to page 14
GLOBAL RANGE-15

Global Range Air Circuit Breakers ACB 4000 A CMF Horizontal Type Fixed ACB 4000 A CMD Horizintal Type Draw-out

 Open the catalog to page 15
GLOBAL RANGE-16

ACB Characteristic Curves Long-time Delay (L) Global Range Air Circuit Breakers

 Open the catalog to page 16
GLOBAL RANGE-17

Global Range Air Circuit Breakers

 Open the catalog to page 17
GLOBAL RANGE-18

ACB Characteristic Curves Instantaneous (I) Ground Fault (G) Global Range Air Circuit Breakers

 Open the catalog to page 18
GLOBAL RANGE-19

Global Range Air Circuit Breakers

 Open the catalog to page 19
GLOBAL RANGE-20

ACB Characteristic Curves Pre Trip Alarm Global Range Air Circuit Breakers

 Open the catalog to page 20
GLOBAL RANGE-21

ACB Accessories Shunt Coil [SHT1] SHT1 is a control device which trips a Circuit Breaker from a remote place, when applying Voltage continuously or instantaneously over 200 ms to the coil terminals (C1 & C2). Global Range Air Circuit Breakers SHT2 - if using a secondary shunt, a UVT cannot be used. 1. Rated Voltage and Characteristics of Trip Coil Rated Voltage [Vn] Opening order Power Consumption (VA or W) Operating Voltage Range [V] * The dotted line to 점선은 User 배선임 be made by the Wiring customerDiagram Wiring Diagram Note) Operating voltage range is the min. rated Voltage standard for each...

 Open the catalog to page 21