ARC FLASH B MULTIRISK PROTECTIVE CLOTHING 12 cal/cm2 APC 1 and 25-40 cal/cm2 APC 2 range Simple and effective daily protection SPECIALIST IN ELECTRICAL RISK PREVENTION
Open the catalog to page 1PROTECTIVE CLOTHING BETTER UNDERSTAND STANDARDS: IEC 61482-2 (items certified in 2018 and beyond) The standard defines the requirements for protection against thermal risks related to electric arcing, to avoid the risk of seconddegree burns. There are currently two methods of classification - the Arc Protection Class (APC) and the Arc Thermal Performance Value (ATPV). (items certified before 2018) The standard characterizes protective constraints relating to electrostatic dissipation used in conjunction with a grounding system to prevent incendiary discharges. The standard determines the classs...
Open the catalog to page 2Efficiency that makes all the difference Anti-Panic ZIP! Our «Red Anti-Panic ZIP» has been specially designed to enable you to quickly and easily remove the garment in the event of an accident. This original ZIP closure lets you remove your PPE (Personal Protective Equipment) up to twice as quickly as similar PPEs fitted with a standard ZIP. The red colour of the ZIP is an extra feature for a safer PPE: your jacket is properly worn when the Velcro secured flap is well-positioned, i. e. the red colour of the zip is not visible. No red visible = a PPE that is being worn correctly! A more hard-wearing...
Open the catalog to page 3The CAT’ARC jacket and trousers have been developed and tested in accordance with current standards whilst still being comfortable to wear and looking stylish. NFPA 70E, ASTM F1959, ASTM F1506 IEC 61482-2 APC 1 ATPV 12 cal/cm² USAGE A high collar provides effective protection up to the neck. MULTI-RISK PROTECTION: CAT’ARC garments offer wide-ranging protection to wearers exposed to electric arc, heat/flames, welding and electrostatic thermal hazards. A strong loop to hang a badge, alarm device for workers working alone, etc. EVERYDAY COMFORT: the fabric and design of the garment have been selected...
Open the catalog to page 4The CAT’ARC switching jacket has been especially designed to be use on top of the usual clothing*, for short operations (e.g. current-breaking operations). This long jacket offers the protection required by the ORG. TST. IE (Organism of Live Working). * Caution, only the areas covered by the switching jacket are protected. NFPA 70E, ASTM F1959, ASTM F1506 Hood with helmet. An adjustable hood for a better protection of the head and the neck in case of a higher risk, to be wear with a visor or a helmet. A high collar provides effective protection up to the neck. A velcro fastening along the entire...
Open the catalog to page 512 cal/cm2 apc 1 coverall The CAT’ARC coverall offers the same performance as the jacket and trousers - multi-risk protection, everyday comfort and attractive design. It offers a total protective solution in a single garment. & IEC 61482-2 ISO 11612 IS° 11611 EN 1149-5 Coverall: 2 outside chest pockets - 2 Italian pockets -2 mesh pockets - central closure with anti-panic zip covered by a velcro-secured flap - adjustable velcro-AFG-1001-* secured cuffs - 1 accessory loop - elasticated belt with XS to 5XL loops - reinforcement at the crotch - reinforcement at the knees - pictograms of the standards,...
Open the catalog to page 6complementary products belt The belt, tested to withstand an arc flash (IEC 61482-1-2 class 1 and ASTM F2621 12 cal/cm2), is the ideal accessory to complete the electrician equipment.
Open the catalog to page 725-40 cal/cm² APC 2 jacket and trousers The CAT’ARC 25-40 cal/cm² jacket and trousers have been developed to provide comfort and protection against the risk of burns due to an electric arc. USAGE Anti-panic zip with double flap inside and outside for an optimal safety. MULTI-RISK PROTECTION: protection against thermal hazards from electric arc, heat and flame, welding and anti-static. OPTIMIZED COMFORT: the garments are made of a set of soft, lightweight technical fabric with a tailored design, allowing the operator to work comfortably. Cuffs that can be tightened to adjust to your body type....
Open the catalog to page 8The switching jacket* has been designed for short operations, such as current-breaking operations. *Please note that the switching jacket protects the covered areas. On the upper part, a central closure with the antipanic zip, quick to put on and take off. On the lower part, a central closure with scratch to maintain the freedom of movement of the wearer.
Open the catalog to page 925-40 cal/cm² APC 2 hood with face shield The CAT’ARC hood provides complete protection for the face and head in the event of an arc hazard: ATPV 25-40 cal/cm² and APC 2. Grey visor for better color recognition. Easily identifiable arc protection level on the outside of the hood. Assembled on a MO-182/1 helmet with a clip system. To place an order: Reference Hood with face shie
Open the catalog to page 10The CAT’ARC 25-40 cal/cm2 APC 2 kits are equipped with a range of PPE to protect the head, face and body in the event of an electric arc. CATU provides the possibility of CAT’ARC garment customization to create a unique product with your logo. Minimum order quantity is only 10 pieces.
Open the catalog to page 11A CHEST MEASUREMENT: Measured around the widest part of the chest, holding the tape measure absolutely horizontal. B WAIST MEASUREMENT: Measured under the navel, holding the tape measure absolutely horizontal. C HIP MEASUREMENT: Measured at the widest point of the hips, holding the tape measure absolutely horizontal. JACKET AND SWITCHING JACKET ComST 2019 - ©nikkytok ©Bernardo Varela _Fotolia.com