Olympian Generator Sets Ratings Guide - 1

OLYMPIAN RATINGS GUIDE Generator Sets © 2009 Caterpillar All Rights Reserved Printed in USA CAT, CATERPILLAR, their respective logos, ACERT, ADEM, “Caterpillar Yellow” and the “Power Edge” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. LEXE7581-02 Exclusively available from your Cat® Dealer. December 2009 For additional information or to find your nearest dealer go to: www.catelectricpowerinfo.com/rg

Open the catalog to page 1
Olympian Generator Sets Ratings Guide - 2

CONTENTS Ratings Guide CONTENTS 1 4 Olympian™ Diesel Ratings - 50 Hz 7 Olympian Diesel Ratings - 60 Hz 9 Olympian Diesel Rental Ratings 9 Diesel Ratings Definitions 11 Olympian Gas Ratings 15 Gas Ratings Definitions 17 Conversions 28 Product Support - Extended Service Coverage (ESC) 29 Notes

Open the catalog to page 2
Olympian Generator Sets Ratings Guide - 3

OLYMPIAN GENERATOR SETS DIESEL

Open the catalog to page 3
Olympian Generator Sets Ratings Guide - 6

DIES EL Rental and Ratings Definitions DIESEL RATINGS DEFINITIONS DIESEL 9 50 Hz & 60 Hz – kVA Generator RPM Prime RPM Prime Set Model 3 – phase output 1500 20 – – XQE20-4 1500 30 1800 34 XQE30-2 1500 60 1800 65 XQE60-2 1500 80 1800 83 XQE80-2 1500 100 1800 106 XQE100-2 1500 150 1800 163 XQE150-2 1500 200 1800 225 XQE200-2 1500 250 – – XQE250-2Models ending in 2 or 4 meet EU Stage II Emissions All ratings at 0.8 pf and 27° C (80.6° F) 60 Hz – kVA (ekW) Generator RPM Standby Prime Set Model 3 – phase output 1800 62.5 (50) 56.3 (45) GEP55-1 1800 75 (60) 68.8 (55) GEP65-5 1800 100 (80) 90 (72)...

Open the catalog to page 6
Olympian Generator Sets Ratings Guide - 7

GAS 50 Hz - International OLYMPIAN GENERATOR SETS GAS OLYMPIAN INTERNATIONAL 50 Hz GAS RATINGS, 10 kVA - 30 kVA Standby kVA (ekW) Prime kVA (ekW) Generator RPM LP Natural LP Natural Set Model Single Phase Output 1500 13 (13) 11.8 (11.8) 11 (11) 10 (10) **GEUG13S1 3000 24 (24) 24 (24) – – **GEUHG24S1 3 – Phase Output 1500 16.5 (13.2) 15 (12) 14 (11.2) 12.5 (10) *GEUG16-1 3000 30 (24) 30 (24) – – *GEUHG30-1 *Ratings at 0.8 pf and 25° C (77° F) **Ratings at 1.0 pf and 25° C (77° F) GAS 11

Open the catalog to page 7
Olympian Generator Sets Ratings Guide - 9

GAS Ratings Definitions OLYMPIAN NORTH AMERICA 60 Hz GAS RATINGS, 25 kVA - 150 kVA GAS 15 G AS 60 Hz - Nor th America 14 GAS GAS RATINGS DEFINITIONS Standby Rating These ratings are applicable to variable loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO - 3046-1. Gas Rating Ratings based on LPG fuel and may derate with natural gas. Please contact dealer for natural gas rating. Standby Generator RPM NG kVA (ekW) LP kVA (ekW) Set Model 3-Phase Output 1800 25 (20) 25 (20) *G25LTA 1800 55 (44) 55 (44) *G55LTA 1800 70...

Open the catalog to page 9
Olympian Generator Sets Ratings Guide - 10

FUEL SYSTEM - DIESEL CONVERSIO NS Reference Day Tank Sizing Tank Size (gal) = Rated BSFC (lb/hp•hr) x Rated HP x Load Factor 7.076 (lb/gal) x Hours Between Refilling + Reserve Requirement OR Rule of Thumb for tank size with 25% reserve 0.056 x Ave. BHP demand x Hours between refills x 1.25 = gal. 0.27 x Ave. BKW demand x Hours between refills x 1.25 = liters. Note: Additional tank capacity required for cooling of recirculated fuel in unit-injected engines. Tank should be located below level of injectors or nozzles. On-Site Power Requirements Based on 100,000 sq ft. of office bldg., etc and...

Open the catalog to page 10
Olympian Generator Sets Ratings Guide - 11

ELECTRICAL TABLES CONVERSIONS Reference CONVERSIONS 19 Alternating Current To Obtain Single Phase Three-Phase Direct Current Kilowatts V × I × P.F. 1.732 × V × I × P.F. V × I 1000 1000 1000 kVA V × I 1.732 × V × I 1000 1000 Horsepower kW kW kW required when kW .746 × EFF. (Gen) .746 × EFF. (Gen) .746 × EFF. (Gen) known (Generator) kW input when HP × .746 HP × .74 HP × .74 HP known (Motor) EFF. (Motor) EFF. (Motor) EFF. (Motor) Ampheres when HP × .746 HP × .746 HP × .746 HP known V × P.F. × EFF. 1.732 × V × EFF × P.F. V × EFF. Ampheres when kW × 100 kW × 100 kW × 100 kW known V × P.F. 1.732...

Open the catalog to page 11
Olympian Generator Sets Ratings Guide - 12

CONVERSIONS Reference REDUCED VOLTAGE STARTERS CONVERSIONS 21 Motor Voltage Line Current Starting Torque Type of Starter (% Line Voltage) (% Full Voltage) (% of Full Voltage) Starting Current Starting Torque Full Voltage Starter 100 100 100 Auto Transformer • 80% Tap 80 68 64 • 65% Tap 65 46 42 • 50% Tap 50 30 25 Resistor Starter Single Step (adjusted for motor 80 80 64 voltage to be 80% of line voltage) Reactor • 50% Tap 50 50 25 • 45% Tap 45 45 20 • 37.5% Tap 37.5 37.5 14 Part Winding (low speed motors only) • 75% Winding 100 75 75 • 80% Winding 100 50 50 CONVERSIONS Reference 20...

Open the catalog to page 12
Olympian Generator Sets Ratings Guide - 16

28 PRODUCT SUPPORT PRODUCT SUPPORT DEFINITIONS PRODUCT SUPPORT Definitions Extended Service Coverage Depending on the engine model and application, Silver, Gold or Platinum & Platinum Plus coverage levels are available from Cat Insurance with terms extended up to 60 months and 10,000 hours. Equipment Coverage Option New Engines ESC Used Engines Advantage Overhauls OPC* Electric Power Extended Service Coverage reimburses 100% of the parts at customer list price, labor at selling rates and travel & mileage charges (less any deductibles) for covered repairs. Available worldwide, Extended...

Open the catalog to page 16
Olympian Generator Sets Ratings Guide - 18

For more information or to find your nearest dealer go to: www.catelectricpowerinfo.com/rg

Open the catalog to page 18