CAT® ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. The open transition power case switch-based Automatic Transfer Switch (ATS) will provide fully functioning transfer in applications where a momentary loss of power is acceptable on retransfer from emergency to normal power supply. The Cat power case switch-based ATS also permits periodic testing of the emergency source without interrupting power to the loads and are available from 200 to 5000 amperes. r Mechanical (cable) and electrical interlocking to prevent paralleling of sources. r Safe manual operation under full load with permanently affixed operating handle r Ambient temperature range: -40°C to 40°C (-40°F to 104°F). r Operating temperature range: -20°C to 70°C (-4°F to 158°F). r Operating humidity: up to 90%. r Relative humidity (non-condensing) r Source paralleling duration is limited to 100 msec or less r Source availability indication r Voltage and frequency sensing r Fastest switching times available (<3 cycles). r Full 60-cycle short time withstand capability r Multiple field programmable time delays r Switch position indication r Source availability indication r Safe manual transfer under load. r Source 1 and 2 auxiliary contacts r Programmable plant exerciser r System test pushbutton r Load shed from emergency r True RMS three phase voltage sensing on Source 1, Source 2 and Load r Frequency sensing on Source 1 and Source 2

Open the catalog to page 1
ATC Power Breaker & Power Case Switch Transfer Switch - 2

OPTIONS • Closed transition • Open transition • Suitable for service entrance • Integral overcurrent protection • 2 or 4-position test switch • Multi meter options available • Selectable Automatic or Non-Automatic operation • Space heaters (recommended for use in NEMA 3R enclosures) • Load sequencing contacts • Surge suppression • Remote communications • Controller availability: ATC-100, ATC-300+, and ATC-800 • Field selectable, multi ratio, control voltage transformer 50/60 Hz OPTIONAL DELAYED TRANSITION INCLUDES: • Time Delay Neutral • In-Phase Transition • Pre-Transfer Signal with 1 N.O....

Open the catalog to page 2
ATC Power Breaker & Power Case Switch Transfer Switch - 3

TESTING STANDARDS_ UL 991 UL standards for safety tests for safety-related controls employing solid-state devices UL 1008 Dielectric test (endurance, withstand, etc.) IEEE® 472 (ANSI C37.90A) Ringing wave immunity/voltage surge test EN55022 (CISPR11): Conducted and radiated emissions EN61000-4-2 Class B Level 4 ESD immunity test EN61000-4-3 (ENV50140) radiated RF, electromagnetic field immunity test EN61000-4-4 Electrical fast transient/burst immunity test EN61000-4-5 IEEE C62.41: Surge immunity test EN61000-4-6 (ENV50141) Conducted immunity test EN61000-4-11 Voltage dips and interruption...

Open the catalog to page 3
ATC Power Breaker & Power Case Switch Transfer Switch - 4

Rating When Used with: Rating of Poles Height Width Depth Weight Lbs. (kg) NEMA 1 Enclosed Fixed Mount Transfer Switch 200-2000 2 90 (2286) 32 (813) 48 (1219) 1050 (477) NEMA 3R Enclosed Fixed Mount Transfer Switch 200-2000 2 90 (2286) 32 (813) 63 (1600) 1600 (727) 2500-3200490 (2286)32 (813)63 (1600)2500 (1136) Dimensions in Inches (mm) & Approximate Shipping lbs (kg)

Open the catalog to page 4
ATC Power Breaker & Power Case Switch Transfer Switch - 5

^^Ratin^^^^^^ofPole^^^^^^Heigh^^^^^^^Widtl^^^^^^^Deptl^^^^^WeightLbs.(kg) NEMA 1 Enclosed Drawout Transfer Switch 200-2000 2 90 (2286) 32 (813) 60 (1524) 1600 (727) NEMA 3R Enclosed Drawout Transfer Switch 200-2000 2 90 (2286) 32 (813) 75 (1905) 2100 (955) Dimensions in inches (mm) and approximate shipping lbs (kg) All dimensions and weights are approximate and subject to change without notice and are not for construction use. Information contained in this publication may be considered confidential. Discretion is recommended when distributing....