ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
4Pages

{{requestButtons}}

Catalog excerpts

ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch - 1

CAT® ATC POWER BREAKER BYPASS ISOLATION OPEN / CLOSED TRANSITION AUTOMATIC TRANSFER SWITCH Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. A Bypass I solation Automatic Transfer Switch (ATS) provides fully functioning transfer in applications where emergency power to critical loads must be maintained at all times with no interruption. This type of design allows for inspection, maintenance or replacement of the power switching mechanisms with no interruption in electrical service. Breaker-based Bypass Isolation ATS are available from 200A to 5,000A. System test pushbutton Load shed from emergency Mimic diagram Safe manual operation under full load with permanently affixed operating handle Drawout capabilities on both ATS, bypass portions and power switching devices completely interchangeable between ATS and bypass units FEATURES • ATC-800 microprocessor-based controller • True RMS voltage and frequency sensing • Full 30-cycle short time withstand capability • 30-cycle, 85 kA short-time rating on power Circuit breaker • Multiple field programmable time delays • Switch position indication • Source availability indication • Source 1 and 2 auxiliary contacts • Programmable plant exerciser

Open the catalog to page 1
ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch - 2

OPTIONS • Integrated service entrance • Open or Closed Transition • Integral overcurrent protection • 2- or 4-position test switch • Multi meter options available • Selectable Automatic or Non-Automatic operation • Space heaters • Load sequencing contacts • Surge suppression • Remote communications • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD) • Field selectable, multi ratio, control voltage transformer 50/60 Hz OPTIONAL DELAYED TRANSITION INCLUDES: • Time Delay Neutral • In-Phase Transition • Pre-Transfer Signal with 1 N.O. and 1 N.C. contacts RATINGS • 200-5000A 2-, 3-,...

Open the catalog to page 2
ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch - 3

UL 991 UL standards for safety tests for safety-related controls employing solid-state devices UL 1008 Dielectric test (endurance, withstand, etc.) IEEE® 472 (ANSI C37.90A) Ringing wave immunity/voltage surge test EN55022 (CISPR11): Conducted and radiated emissions EN61000-4-2 Class B Level 4 ESD immunity test EN61000-4-3 (ENV50140) radiated RF, electromagnetic field immunity test EN61000-4-4 Electrical fast transient/burst immunity test EN61000-4-5 IEEE C62.41: Surge immunity test EN61000-4-6 (ENV50141) Conducted immunity test EN61000-4-11 Voltage dips and interruption immunity FCC Part 15...

Open the catalog to page 3
ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch - 4

Ampere Rating Depth Standard Terminals ** Load Side, Normal and Standby Neutral Shipping Source Connection Weight Lbs. (kg) NEMA 1 Enclosed Drawout Transfer Switch 200-2000A 2 90 (2286) 64 (1626) 60 (1524) Consult Factory Dimensions in Inches (mm) & Approximate Shipping lbs (kg) * Add 6" to the w idth and 3" to the depth for seismic brackets w here required All dimensions and weights are approximate and subject to change without notice and are not for construction use. Standard Terminals - ( ) indicate the quantity of supplied terminals per pole. Information contained in...

Open the catalog to page 4