ATC Contactor-Based Bypass Isolation Transfer Switch
5Pages

{{requestButtons}}

Catalog excerpts

ATC Contactor-Based Bypass Isolation Transfer Switch - 1

AUTOMATIC TRANSFER SWITCH CAT® ATC CONTACTOR-BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH Ca t® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. A Bypass Isolation Automatic Transfer Switch (ATS) provides fully functioning transfer in applications where emergency power to critical loads must be maintained at all times wit h no interruption. This type of design allows for ins pection, maintenance or replacement of the power sw itching mechanisms with no interruption in electrical service. Contactor -based Bypass Isolation ATS are available from 100A to 1200A. • Source availability indication • Source 1 and 2 auxiliary contacts • Programmable plant exerciser • System test pushbutton • Load shed from emergency • Mimic diagram • Ability to test power switching isolated components controller • True RMS voltage and frequency sensing • Maintains fully automatic capability while in bypass mode (optional) • Single motion rack-out with the door closed • Multiple field programmable time delays • Switch position indication

Open the catalog to page 1
ATC Contactor-Based Bypass Isolation Transfer Switch - 2

OPTIONS • Drawout capabilities on both ATS bypass portions and power switching devices completely interchangeable between ATS and bypass units • Open, Delayed or Closed Transition • 2- or 4-position test switch • Multi-meter options available • Selectable Automatic or Non-Automatic operation • Space heaters (recommended for use in NEMA 3R enclosures) • Load sequencing contacts • Surge suppression • Remote communications • Seismic Qualified (BOCA, CBC, IBC, UBC) • Field selectable, multi ratio, control voltage transformer 50/60 Hz • Dual drawout type is field configurable for top or...

Open the catalog to page 2
ATC Contactor-Based Bypass Isolation Transfer Switch - 3

UL 991 UL standards for safety tests for safety-related controls employing solid-state devices UL 1008 Dielectric test (endurance, withstand, etc.) IEEE® 472 (ANSI C37.90A) Ringing wave immunity/voltage surge test EN55022 (CISPR11): Conducted and radiated emissions EN61000-4-2 Class B Level 4 ESD immunity test EN61000-4-3 (ENV50140) radiated RF, electromagnetic field immunity test EN61000-4-4 Electrical fast transient/burst immunity test EN61000-4-5 IEEE C62.41: Surge immunity test EN61000-4-6 (ENV50141) Conducted immunity test EN61000-4-11 Voltage dips and interruption immunity FCC Part 15...

Open the catalog to page 3
ATC Contactor-Based Bypass Isolation Transfer Switch - 4

AUTOMATIC TRANSFER SWITCHFIXED & DRAWOUT BYPASS ISOLATION CONTACTOR BASED TRANSFER SWITCHES 100-400A* Ampere Number Conduit Shipping Rating of Poles Entry Height Width Depth Weight Lbs. (kg) Dimensions in Inches (mm) & Approximate Shipping lbs (kg) * Add 6" to width for seismic brackets where required 1 Dual drawout type is field configurable for top or bottom entry 2 Fixed type conduit entry (top or bottom) must be specified at type of order All dimensions and weights are approximate and subject to change without notice and are not for construction use.

Open the catalog to page 4
ATC Contactor-Based Bypass Isolation Transfer Switch - 5

AUTOMATIC TRANSFER SWITCHFIXED& DRAWOUT BYPASS ISOLATION CONTACTOR BASED TRANSFER SWITCHES 100A-1200A12 Ampere Number Conduit Shipping Rating of Poles Entry Height Width Depth Weight Lbs. (kg) NEMA 3R Drawout Bypass 1 NEMA 1 Fixed Bypass 2 NEMA 3R Fixed Bypass 2 Dimensions in Inches (mm) & Approximate Shipping lbs (kg) Add 6" to width for seismic brackets where required 1 Dual drawout type is field configurable for top or bottom entry 2 Fixed type conduit entry (top or bottom) must be specified at type of order All dimensions and weights are approximate and subject to change...