1. Catalogs
  2. CAT Electric Power
  3. Electric Power Products Full Line

Electric Power Products Full Line

Electric Power Products Full Line
1 / 44 PagesView full catalog

Electric Power Products Full Line

Product catalog summary
Overview: This document serves as a comprehensive guide on electric power ratings for Cat® Diesel and Gas Generator Sets, detailing specifications for various models and configurations. It includes ratings for both 50 Hz and 60 Hz systems, rental power ratings, and definitions of diesel and gas ratings.
Cat® Diesel Generator Sets:
  • 50 Hz Ratings: Range from 275 kVA to 4000 kVA, featuring models like 3406C, C13, C15, C18, and 3512B known for low BSFC and emissions.
  • 60 Hz Ratings: Available from 36 ekW to 4000 ekW, primarily for North America, with models such as C4.4 ESE, C9 ESE, and 3516C EPA T4.
  • Rental Power Ratings: 60 Hz ratings from 18 ekW to 1250 ekW, including models like XQ20, XQ60, and XQ1250G.
Cat® Gas Generator Sets:
  • 50 Hz Continuous Ratings: From 66 kW to 9700 kW, with models like G3306 NA, G3516, and G20CM34, suitable for natural gas and biogas.
  • 60 Hz Standby Ratings: Range from 235 kW to 1040 kW, featuring models such as G3406 TA and G3516.
Definitions:
  • Emergency Standby Power (ESP): For emergency outages, with an average power output of 70% of the rating.
  • Standby Power: For interruptions of normal power, with an average output of 70%.
  • Prime Power: For unlimited time with varying load, average output at 70%.
  • Continuous Power: For constant load without variation, average output between 70-100%.
Additional Information:
  • EMCP 4: Details on control systems for generator sets.
  • Systems Products: Information on additional system products available.
  • Conversion Tables: Useful for converting various power ratings and measurements.
  • Product Support: Definitions and customer support agreements for product maintenance and service.
Specifications and Ratings: The document provides detailed specifications for various gas engines, including power ratings at different RPMs and fuel types (Natural Gas and Biogas). Engines are categorized as Naturally Aspirated (NA) or Turbocharged & Aftercooled (TA), with specific power outputs listed for each model.
Gas Rating Definitions: Definitions for standby and continuous power ratings are provided, explaining the conditions under which these ratings apply, such as load variations and operational hours, adhering to ISO standards.
EMCP 4 Series Controllers: The EMCP 4 series includes models 4.1 to 4.4, each offering varying levels of engine control and monitoring capabilities, from basic controls to advanced features like automatic generator set paralleling and load sharing.
Paralleling Switchgear and UPS Systems: Features of paralleling switchgear systems are outlined, customizable for various applications such as emergency standby and utility paralleling. UPS systems with different output capacities and types, including double conversion and line interactive models, are detailed.
Electrical and Fuel System Conversions: Conversion tables and formulas are provided for calculating electrical parameters such as kW, kVA, and amperes, along with guidelines for diesel fuel system sizing and on-site power requirements.
Reduced Voltage Starters: Various types of reduced voltage starters are described, including full voltage, auto transformer, resistor, and reactor starters, comparing characteristics like starting current and torque.
Engine Room Ventilation: Guidelines for engine room ventilation are likely included to ensure optimal performance and safety, with calculations provided for ventilation air requirements.
Comparison of Reduced Voltage Starting Methods:
  • Autotransformer: Least line disturbance, same terminal voltage, ease of control, consistent maintenance, and power draw.
  • Reactor: Similar to autotransformer with consistent power draw and maintenance.
  • Two-Step Part Winding: Smooth acceleration, lacks starting current adjustment, more line disturbance than autotransformer.
  • Primary Resistor: Lower terminal voltage in small sizes, smooth acceleration, average torque, adds considerable kW load to generator set.
Engine Room Ventilation: Ventilation can be calculated using specific formulas for cfm and m3/min, considering heat radiation and permissible temperature rise.
Conversion Factors: Extensive tables are provided for converting units of flow, energy, area, length, weight, volume, capacity, power, and pressure, including specific conversions for U.S. and metric units.
Product Support and Customer Agreements:
  • Extended Service Coverage (ESC): Offers various coverage levels (Silver, Gold, Platinum, Platinum Plus) for Cat Electric Power Products, covering parts, labor, and travel costs.
  • Customer Support Agreements (CSA): Tailored agreements to reduce production costs, including Preventive Maintenance (PM) and Total Maintenance and Repair (TM&R) agreements, covering inspections, maintenance, and use of genuine Cat parts.
See more

Catalog excerpts

Electric Power Products Full Line-3

Caf Diesel Generator Sets Rental Power Ratings 9 Definition of Diesel Ratings 10 Product Support Definitions 39 Product Support- Customer Support Agreements 40

 Open the catalog to page 3
Electric Power Products Full Line-6

Configuration Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC, Low Emissions Low BSFC Low BSFC Low BSFC, Low Emissions Low BSFC, Low Emissions Low BSFC, Low Emissions Low BSFC, Low Emissions Low BSFC Low BSFC, Low Emissions Low BSFC, Low Emissions Low BSFC Low BSFC Low BSFC *Rating does not include package mounted radiator

 Open the catalog to page 6
Electric Power Products Full Line-7

CAT 50 Hz DIESEL RATINGS, 1368 kVA – 17463 kVA kVA Standby Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC

 Open the catalog to page 7
Electric Power Products Full Line-8

CAT 60 Hz DIESEL RATINGS, 36 ekW – 175 ekW Available only for North America   *All ratings at 1.0 pf **All ratings at 0.8 pf (ESE) EPA Emergency Stationary Exempt CAT 60 Hz DIESEL RATINGS, 180 ekW – 250 ekW ekW Standby (ESE) EPA Emergency Stationary Exempt

 Open the catalog to page 8
Electric Power Products Full Line-9

ESE Low BSFC Low BSFC ESE, Low BSFC Low BSFC Low BSFC Low BSFC ESE, Low BSFC ESE, Low BSFC EPA Tier 4 Interim, ESE, Low BSFC ESE, Low BSFC ESE, Low BSFC ESE, Low BSFC Low BSFC Low BSFC ESE, Low BSFC Low BSFC EPA Tier 4 Interim, ESE, Low BSFC Low BSFC ESE, Low BSFC Low BSFC Low BSFC Low BSFC, Low Emissions Low BSFC, Low Emissions ESE Low BSFC Low BSFC, Low Emissions EPA T4, ESE Low BSFC EPA T4, ESE EPA Tier 4 Interim, ESE, Low BSFC EPA Tier 4 Interim, ESE, Low BSFC ESE, Low BSFC (ESE) EPA Emergency Stationary Exempt (ESP) Emergency Standby Rating *Rating does not include package mounted radiator...

 Open the catalog to page 9
Electric Power Products Full Line-10

CAT 60 Hz DIESEL RATINGS, 980 ekW – 13970 ekW ekW Standby Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC Low BSFC

 Open the catalog to page 10
Electric Power Products Full Line-11

rental power ratings CAT 60 Hz RENTAL POWER RATINGS, 18 ekW – 1250 ekW ekW Standby Rental Generator Model EPA Tier 4 Interim EPA Tier 4 Interim EPA Tier 3 EPA Tier 3 EPA Tier 4 Interim EPA Tier 4 Interim EPA Tier 4 Interim EPA Tier 4 Interim EPA NSPS SI Capable *Subject to availability (Flex Credits)

 Open the catalog to page 11
Electric Power Products Full Line-12

ratings definitions CAT DIESEL RATING DEFINITIONS Emergency Standby Power (ESP) Output available with varying load for the duration of an emergency outage. Average power output is 70% of the emergency standby power rating. Typical operation is 50 hours per year with maximum expected usage of 200 hours per year. Standby Power Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Mission Critical Standby...

 Open the catalog to page 12
Electric Power Products Full Line-13

ratings definitions Prime Power Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand of 100% of prime-rated ekW with 10% of overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year. Load Management Output available with varying load for maximum 500 hours a year. Average power output is 100% of the prime power rating. Typical peak demand of 100% of prime-rated ekW. Overload operation not available. Continuous Power Output available without varying load...

 Open the catalog to page 13
Electric Power Products Full Line-16

Ratings at ISO 3046-1 conditions. SCAC Temp = 40-53° C (104-127° F). PF = 1.0. Natural Gas at 35.6 MJ/N·m3 (905 Btu/ft3), MN = 80. Biogas (Landfill, Sewage, Digester Gas) at 18.0-23.6 MJ/N·m3 (457-600 Btu/ft3) and MN = 130-134. NA = Naturally Aspirated, Stoichiometric Engine: *Catalyst Rating Availability TA = Turbocharged & Aftercooled, Stoichiometric Engine: *Catalyst Rating Availability All other engines: Lean Burn

 Open the catalog to page 16
Electric Power Products Full Line-17

Ratings at ISO 3046-1 conditions. SCAC Temp = 53° C (127° F). Standby ratings at PF = 0.8. Natural Gas at 35.6 MJ/N·m3 (905 Btu/ft3), MN = 80. Contact dealer for LPG or Propane ratings. Biogas (Landfill, Sewage, Digester Gas) at 18.0-23.6 MJ/N·m3 (457-600 Btu/ft3) and MN = 130-134. NA = Naturally Aspirated, Stoichiometric Engine: *Catalyst Rating Availability TA = Turbocharged & Aftercooled, Stoichiometric Engine: *Catalyst Rating Availability All other engines: Lean Burn

 Open the catalog to page 17
Electric Power Products Full Line-18

Ratings at ISO 3046-1 conditions. SCAC Temp = 40-53° C (104-127° F). PF = 1.0. Natural Gas at 35.6 MJ/N·m3 (905 Btu/ft3), MN = 80. Biogas (Landfill, Sewage, Digester Gas) at 18.0-23.6 MJ/N·m3 (457-600 Btu/ft3) and MN = 130-134. NA = Naturally Aspirated, Stoichiometric Engine: *Catalyst Rating Availability TA = Turbocharged & Aftercooled, Stoichiometric Engine: *Catalyst Rating Availability All other engines: Lean Burn

 Open the catalog to page 18
Electric Power Products Full Line-19

ratings definitions Standby Power Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Fuel stop power in accordance with ISO 3046-1. Continuous Power Output available without varying load for an unlimited time. Average power output is 70-100% of the continuous power rating. Typical peak demand is 100% of continuous rated ekW for 100% of operating hours. Continuous power is in accordance with ISO 8528-1....

 Open the catalog to page 19
Electric Power Products Full Line-20

ACK_RESET EVEN^LOG RUN_AUTO STOP CONTROL AC ENGINE MAIN MENU

 Open the catalog to page 20
Electric Power Products Full Line-22

EMCP 4.1 The EMCP 4.1 provides basic engine controls – stop/run/auto push button controls, cycle crank, and cool down timer. The 3.8 inch graphical display supports multiple languages, including character languages such as Chinese, Arabic, Russian, and Japanese. The EMCP 4.1 provides monitoring of generator electrical output, including AC voltage, current, and frequency, and mechanical information such as oil pressure, oil temperature, coolant temperature, engine speed, and battery voltage. It also provides a number of protective functions, such as warnings and shutdowns for over/under voltage,...

 Open the catalog to page 22

All CAT Electric Power catalogs and technical brochures

  1. C2.2

    3  Pages

  2. Cat® C1C2

    6  Pages

  3. C1.1

    5  Pages

  4. RP3600

    2  Pages

  5. RP6500 E

    2  Pages

  6. RP5500

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.