1. Catalogs
  2. CAT Electric Power
  3. ATC-100 Controller

ATC-100 Controller
1 /2Pages

ATC-100 Controller

ATC-100 Controller
1 /2Pages

Catalog excerpts

ATC-100 Controller-1

AUTOMATICTRANSFER SWITCH GfiT AUTOMATICTRANSFER SWITCH GfiT ATC-100 CONTROLLER The ATC-100 is a comprehensive and multifunctional micropro cessor-based ATS controller. It is a compact and self-contained panel-mounted device that is designed to replace traditional relay and solid-state logic panels. The ATC provides both fixed and jumper-selectable settings to allow for a range of applications. It operates from all system voltages between 120 and 480 Vac, single-phase and three phase at 50 or 60 Hz. The ATC-100 monitors the condition of the three-phase line to lin e voltage and the frequency of both the utility and generator power sources. It can also be set up for single-phase operation. The ATC-100 provides the necessary intelligence to ensure that the transfer switch operates properly through a series of selectable sensing and timing functions FEATURES • Source 1 sensing: • Undervoltage / underfrequency • Overfrequency • Source 2 sensing: • Undervoltage / overfrequency • Controller settings via jumpers located at the rear of the unit • Mimic diagram with source available and connected LED indication • System test pushbutton • Plant Exerciser - Selectable day, off, 7, 14 or 28 day intervals with fixed 15 minute run time • Monitor utility and generator power source voltages and generator power source frequency • Provides undervoltage protection of the utility and generator power sources • Provides underfrequency and overfrequency protection of the generator power source • Permits easy customer setup • Permits system testing • In-phase transition

 Open the catalog to page 1
ATC-100 Controller-2

PRODUCT SPECIFICATIONS ATC-100 CONTROLLER SPECIFICATIONS DescriptionSpecification Input control voltage95 to 145 Vac 50/60 Hz Voltage measurements of Utility Vab generator Vab Utility VBC generator VBC Utility VCA generator VCA Voltage measurement range0 to 575 Vac rms (50/60 Hz) Voltage measurement accuracy ± 1% of full scale Frequency measurements ofGenerator Frequency measurement range 40 Hz to 70 Hz Frequency measurement accuracy ±0.3 Hz over the measurement range Undervoltage dropout80% of the niminal system voltage Undervoltage pickup90% of the niminal system voltage Underfrequency dropout...

 Open the catalog to page 2

All CAT Electric Power catalogs and technical brochures

  1. C2.2

    3  Pages

  2. Cat® C1C2

    6  Pages

  3. C1.1

    5  Pages

  4. RP3600

    2  Pages

  5. RP6500 E

    2  Pages

  6. RP5500

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.