Catalog excerpts
PRODUCTS FOR REFRIGERATING SYSTEMS GENERAL DATA FROM QUALITY OUR NATURAL DEVELOPMENT. Achieved the goal of fty years working in the industry of Refrigeration and Air Conditioning, Castel Quality Range of Products is well known and highly appreciated all over the world. Quality is the main issue of our Company and it has a special priority, in every step, all along the production cycle. UNI EN ISO 9001:2008, issued by ICIM, certies the Quality System of the Factory. Moreover Castel Products count a number of certications in conformity with EEC Directives and with European and American Quality Approval. We produce on high tech machinery and updated automatic production lines, operating in conformity with the safety and environment standards currently enforced. Castel oers to the Refrigeration and Air Conditioning Market and to the Manufacturers fully tested products suitable with HCFC and HFC Refrigerants currently used in the Refrigeration & Air Conditioning Industry. General data 1
Open the catalog to page 1September 2011 General data 2
Open the catalog to page 2INDICE DIRECTIVE 97/23/EC (PED) DIRECTIVE 2002/95/EC (ROHS) PRESSURE CONTAINMENT All the products illustrated in this Handbook, if submitted to hydrostatic test, guarantee a pressure strength at least equal to 1,43 x PS in compliance with the Directive 97/23/EC. All the products illustrated in this Handbook, if submitted to burst test, guarantee a pressure strength at least equal to 3 x PS according to EN 378-2 : 2008 Standard. A great number of products illustrated in this Handbook can guarantee an higher pressure strength, equal to 5 x PS according the UL Standard 207: 2009. PAG 07 KV...
Open the catalog to page 3Application of Directive 97/23/EC of the European Parliament and of the Council, of 29 May 1997, concerning pressure equipment towards Castel refrigeration products e Directive 97/23/EC (PED) applies to the design, manufacture and conformity assessment of pressure equipment and assemblies with a maximum allowable pressure “PS” greater than 0,5 bar with the exception of the possibilities listed in Article 1, Section 3 of the same Directive. Since 30 May 2002 the Directive has become mandatory and, in the Member States of European Community, it has been possible to place on the market only...
Open the catalog to page 4Application of Directive 2002/95/EC of the European Parliament and of the Council, of 27 January 2003, on the restriction of the use of certain hazardous substances in electrical and electronic equipment towards Castel refrigeration products e purpose of Directive 2002/95/EC (RoHS Directive) is to prevent or restrict the use of hazardous substances in electrical and electronic equipment and to contribute to the environmentally sound recovery and disposal of waste electrical and electronic equipment. RoHS Directive shall apply to electrical and electronic equipment falling under the...
Open the catalog to page 5Application of Regulation 1907/2006/EC of the European Parliament and of the Council, of 18 December 2006, on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) towards Castel refrigeration products e European Regulation 1907/2006/EC concerning the Registration, Evaluation, Authorization and Restrictions of Chemicals, the so called REACH Regulation, was published on GUCE L136 dated 29 May 2007 and came into force in the European Union on the 1st June 2007. is Regulation requires to pre-register and register chemical substances produced or imported into Europe...
Open the catalog to page 6CONNECTIONS OF CASTEL PRODUCTS Castel products can be supplied with dierent connections. In particular Castel products are produced either with threaded connections or solder connections. Table 1 shows the equivalence between Castel codes and dimensions in inches. ese codes are commonly used in the international market. Table 2 shows the equivalence between Castel codes and dimensions in millimeters. Description of connections that are currently used for Castel products. 1) readed connections ey can be of three dierent types: FLARE Straight threaded connection (according to SAE J513-92;...
Open the catalog to page 7THE Kv FACTOR e correct sizing of tubes and components of a refrigerating system is of the utmost importance for all kinds of plants; over-sizing and undersizing are both to be avoided since they are equally hazardous for the correct operation of the system. e correct selection of a component is based on the knowledge of the relationship between capacity and pressure drop through that component. For this purpose, EN 60534-1, EN 60534-2-1 and EN 60534-2-3 standards require manufacturers to specify the Kv coecient for every product. predict actual working conditions. As a result: – Liquid...
Open the catalog to page 91) Calculation example for liquid line: Evaluation of pressure drop across the valve under the following operating conditions: Q, = 17,23 [kW] refrigeration capacity of R407C on liquid line (table 1) L, = 0,84 correction factor of R407C for TLiquid = 50 °C and LIQUID LINE Using table 3b a pressure drop of 0,13 bar corresponds to a correction factor L2 = 0,92. Such a pressure drop is compatible with the minimum differential pressure required by the valve. TABLE 2- Correction factors - L, of the refrigeration capacity for temperatures different from standard values. General data
Open the catalog to page 102) Calculation example for suction line: Valve selection under the following conditions: Q, = 2,23 [kW] refrigeration capacity of R404A on suction line (table 1) S, = 0,72 correction factor of R404A for Tcondensation = 40 °C and S2 = 0,86 correction factor for pressure drop of 0,11 bar (table 5a) The result involves the selection of a 1078/9 valve with Kv = 10 [m3/h] SUCTION LINE TABLE 4- Correction factors - Si of the refrigeration capacity for temperatures different from standard values. General data
Open the catalog to page 123) Calculation example for hot gas line: Valve selection under the following conditions: Q, = 13,6 [kW] refrigeration capacity of R41 OA on hot gas line (table 1) S, = 1,01 correction factor of R41 OA for Tcondensation = 40 °C and S2 = 0,71 correction factor for pressure drop of 0,5 bar (table 7a) The result involves the selection of a 1078/5 valve with Kv = 2,61 TABLE 6- Correction factors - Hi of the refrigeration capacity for temperatures different from standard values. General data
Open the catalog to page 14All CASTEL catalogs and technical brochures
-
CASTEL - 2013 General Catalogue
105 Pages
-
VALVES FOR REFRIGERATING SYSTEMS
34 Pages
-
REFRIGERATING SYSTEMS PROTECTORS
38 Pages
-
OIL CONTROL SYSTEM
22 Pages
-
PRODUCTS FOR CO2 SYSTEMS
7 Pages
-
Products catalogue
101 Pages
Archived catalogs
-
Products Catalogue 2008
84 Pages
-
Threaded brass fittings
10 Pages
-
Valves
20 Pages
-
Oil separators
6 Pages
-
Dehydrators and Filters
28 Pages
-
Water regulating valves
6 Pages
-
Check valves
6 Pages
-
Safety devices
16 Pages
-
Solenoid valves
18 Pages
-
Expansion valves
16 Pages