Catalog excerpts
Refrigeration & Climate Components Solutions ' Permanent refrigerant filtering, regulation and expansion element protection in refrigerating and air conditioning installations. ' These filters are particularly suited for commercial refrigerating applications and installations with important liquid line lengths. Functional features •Products are compatible with HFCs, HCFCs, CFCs, as well as with their associated oils and additives. Products are designed for use of non-hazardous refrigerants from group 2 of PED •Product classification in CE categories is performed using the PED 97/23/EC table, corresponding to a nominal diameter-based •Product is ergonomie for quick maintenance interventions. •Body made of die-cast brass with brazed connection. •Filtration preventing propagation within the circuit of particles bigger than 150 microns in standard version, with a filtration area > Supply of a 50-micron filtrating sleeve on request. 'The stainless steel filtrating sleeve can be removed for cleaning, without removing the filter case and without de-brazing the connections, thus allowing important time savings during maintenance operations. > Plug can be handled with a flat spanner. 'Air-tightness guaranteed thanks to a PTFE O-ring. ■ Compact product for ease of assembly in reduced > Upon request, FILTRY filters can be supplied with a moisture indicator instead of the basic plug » GOST certified products. Non-binding documents
Open the catalog to page 1g 2 Refrigeration & Climate Components Solutions ' FILTRY dirt filters are to be mounted on the liquid line between the receiver and r The refrigerant flow direction, indicated by an arrow on filter case should be complied r It is necessary to remove the filtrating sleeve and the O-ring before assembling r After brazing, when the base temperature is sufficiently low, put the O-ring back into its recess and screw back the plug complying with the recommended tightening torque of 'After each removal of the plug, impera-tively replace the PTFE O-ring; it is preferable to position, in a first...
Open the catalog to page 2Non-binding documents
Open the catalog to page 3All CARLY catalogs and technical brochures
-
DDCY
5 Pages
-
CCY F
5 Pages
-
BDCY / ACY / BACY
17 Pages
-
TSGY
4 Pages
-
DDNCY
4 Pages
Archived catalogs
-
Liquid sight glasses
4 Pages
-
Check valves
5 Pages
-
Filter drier receiver units
3 Pages
-
Ball valves
4 Pages
-
Oil filters
2 Pages
-
Liquid receivers
7 Pages
-
Oil separators
10 Pages
-
Discharge line mufflers
3 Pages
-
Anti-acid filter driers
8 Pages