Proximity Sensors Inductive Analogue Position Sensor Types EI, M18, M30 • Nickel-plated brass housing, cylindrical • Diameter: M18, M30 • Sensing range: EI 1805 I020: 2 to 5 mm EI 3008 I020: 3 to 8 mm • Power supply: 15 to 30 VDC • Current source output: 0 to 20 mA • Protection: Reverse polarity, internal current limiter • 2 m cable or plug M12 Product Description Cylindrical analogue position sensor in M18 and M30 nickel-plated brass housings. High degree of linearity, output current 0 to 20 mA. Can be extended with level amplifier relay S 183 and analogue display to make up complete measuring systems. Type: Inductive switch Housing diameter Rated operating dist. (mm) Current output 0 to 20 mA Connection type Housing diameter Rated operating dist. (Sn) Ordering no. Output type 0 to 20 mA Ordering no. Output type 0 to 20 mA Type Selection For flush mounting in metal Specifications Rated operational volt. (Ue) (UB) Ripple Rated operational current (Ie) No-load supply current (Io) Protection Transient voltage Power ON delay Rate of rise Assured operating dist. (Sa) Linearity Repeat accuracy (R) Temperature drift 17 to 27 VDC 15 to 30 VDC (ripple included) ≤ 10% 0 to 20 mA (R load: 0 to 500 Ω) Max. 30 mA (current limiter) ≤ 7 mA (no load) Reverse polarity current limiter ≤ 2 kV/0.5 J (prepared) Safe operation after 1 s EI 1805 I020 ≥ 1 mm/ms EI 3008 I020 ≥ 3 mm/ms EI 1805 I020 2 to 5 mm EI 3008 I020 3 to 8 mm ± 3% of full scale ≤ 1% EI 1805 I020 ≤ 2 µm/°C per mm EI 3008 I020 ≤ 1 µm/°C per mm Specifications are subject to change without notice (04.05.10) Ambient temperature Operating Storage Degree of protection Housing material Body Front Back Cable Weight (cable included) Tightening torque CE-marking -15° to +65°C (+5° to +144°F) -20° to +70°C (-4° to +158°F) IP 67 (Nema 1, 3, 4, 6, 13) Nickel-plated brass Blue thermoplastic polyester Black thermoplastic polyester 2 m, 3 x 0.25 mm2 grey PVC, oil proof EI 1805 I020 85 g EI 3008 I020 195 g EI 1805 I020 17.5 Nm EI 3008 I020 35.0 Nm Yes
Open the catalog to page 1CARLO GAVAZZI Power Supplies Installation Hints To avoid interference from inductive voltage/ current peaks, separate the prox. switch pow- er cables from any other power cables, e.g. motor, contactor or solenoid cables Relief of cable strain The cable should not be pulled Protection of the sensing face A proximity switch should not serve as mechanical stop Switch mounted on mobile carrier cable should be avoided Specifications are subject to change without notice (04.05.10)
Open the catalog to page 26 Pages
8 Pages
6 Pages
2 Pages
2 Pages
3 Pages
2 Pages
3 Pages
2 Pages
6 Pages
5 Pages