CX-Series Circuit Breaker
1 / 12Pages

Catalog excerpts

CX-Series Circuit Breaker - 1

CX-SeriesCIRCUIT BREAKER The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance even in the most demanding applications. Resources: Download 3D CAD Files Carling Technologies8 Innovative Designs. Powerful Solutions. Product Highlights: ♦ UL 489 & UL 489B Listed ♦ TUV Certified IEC/EN 60947-2 ♦ Temperature stable hydraulic-magnetic overcurrent sensing technology ♦ Optional relay trip circuit permitting remote operator system shut down ♦ Perfect fit for 380VDC Applications High DC Voltage Applications: ♦ Datacom, PDU and UPS Systems ♦ Power Supplies and Convertors ♦ Mission Critical Equipment ♦ Renewable Energy Systems ♦ Motor Controllers ♦ Charging Stations ♦ Smart Grids Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231

Open the catalog to page 1
CX-Series Circuit Breaker - 2

2 | CX-Series Circuit Breaker - Design Features DESIGN FEATURES HYDRAULIC/MAGNETIC SENSING COIL UPPER ARC RUNNER Aids in motivating arc off of movable contact and into arc chamber PATENT PENDING MAGNETIC FLUX BOOSTING TERMINAL CONFIGURATION Design enhances motivation of arc into arc chamber LOWER ARC RUNNER Aids in motivating arc off of stationary contact and into arc chamber ARC SPLITTER RETAINER with integrated pressurizing walls LARGE ARC GAP To generate high arc voltages (12) ARC DEIONIZING SPLITTER PLATES Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone:...

Open the catalog to page 2
CX-Series Circuit Breaker - 3

CX-Series Circuit Breaker - General Specifications CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS *Manufacturer reserves the right to change product specification without prior notice.

Open the catalog to page 3
CX-Series Circuit Breaker - 4

4 | CX-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage 600 VDC Overload 50 operations at 600% of rated current for UL489, and at 150% of rated current for UL1077. Physical Number of Poles Termination Terminals Termination Barrier Mounting Actuator Internal Circuit Config. Materials Weight Standard Color CURRENT (AMPS) 1- 2 poles, + Auxiliary Switch Pole. 10-32 or M5 Screw Terminals 1/4-20 or M6 Threaded Stud Standard with multi-pole constructions Threaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole) Handle, 1 per pole. Series Trip Housing...

Open the catalog to page 4
CX-Series Circuit Breaker - 5

CX-Series Circuit Breaker - UL489 - Ordering Scheme | 5 Series Actuator Poles Circuit Aux/Alarm Actuator Mounting Color & Inserts Rating Agency 2 ACTUATOR X Handle, one per pole 8 TERMINAL 2 Screw Terminal, 10-32 3 Stud, 1/4-20 5 Screw Terminal, M5 6 Stud, M6 9 ACTUATOR COLOR & LEGEND 4 CIRCUIT B Series Trip (current) 5 AUXILIARY/ALARM SWITCH 0 Without Aux Switch Actuator Color White Black Red Green Blue Yellow Gray Orange Legend Color Black White White White White Black Black Black 6 FREQUENCY & DELAY 11 DC Ultra Short 10 MOUNTING INSERTS A 6-32 Thread B M3 Thread 7...

Open the catalog to page 5
CX-Series Circuit Breaker - 6

6 | CX-Series Circuit Breaker - UL489B - Ordering Scheme Series Actuator Poles Circuit Relay Trip Actuator Mounting Color & Inserts Rating Agency 2 ACTUATOR X Handle, one per pole A Stud, 1/4-20, with 10-32 Screw Terminals on Voltage Pole 9 HANDLE COLOR & LEGEND 4 CIRCUIT S Switch Only Actuator Color White Black Red Green Blue Yellow Gray Orange Legend Color Black White White White White Black Black Black 5 RELAY TRIP VOLTAGE COIL RATING 1,2 0 Without Relay Trip Voltage Coil A 12 VDC 10 MOUNTING INSERTS A 6-32 Thread B M3 Thread 6 FREQUENCY & DELAY 03 DC...

Open the catalog to page 6
CX-Series Circuit Breaker - 7

CX-Series Circuit Breaker - UL1077 - Ordering Scheme | 7 Series Actuator Poles Circuit Aux/Alarm Terminal Actuator Mounting Color & Inserts Rating Agency 1 SERIES C 2 ACTUATOR X Handle, one per pole 9 ACTUATOR COLOR & LEGEND 4 CIRCUIT A Switch Only (no coil) 1 9 B Series Trip (current) G Relay Trip (voltage) 1 2, 3, 9 Actuator Color White Black Red Green Blue Yellow Gray Orange Legend Color Black White White White White Black Black Black 5 AUXILIARY SWITCH 0 Without Aux Switch 10 MOUNTING INSERTS A 6-32 Thread B M3 Thread 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch...

Open the catalog to page 7
CX-Series Circuit Breaker - 8

8 | CX-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme Dimensional Specifications: in. [mm] 0.755 0.755 [19.18] [19.18] MAXIMUM MAXIMUM SHOWN WITH STUD TERMINAL CONFIGURATION SHOWN WITH STUD TERMINAL CONFIGURATION SHOWN WITH STUD TERMINAL CONFIGURATION 2.736 [69.49] (WITH SCREW TERMINAL) 2.946 [74.83] (WITH STUD TERMINAL) 3.276 [83.21] (UNFOLDED BARRIER) 2.736 [69.49] 2.736 TERMINAL) (WITH SCREW [69.49] 2.946 (WITH SCREW TERMINAL) [74.83] 2.946 (WITH STUD TERMINAL) [74.83] 3.276 (WITH STUD TERMINAL) [83.21] 3.276 (UNFOLDEDWITH SCREW SHOWN BARRIER) [83.21] TERMINAL...

Open the catalog to page 8
CX-Series Circuit Breaker - 9

CX-Series Circuit Breaker - UL489B - Dimensional Specifications | 9 CX3 - 2 POLE SWITCH (CX2)SHOWN WITH OPTIONAL VOLTAGE POLE 50A-100A DEVICE, 600VDC CX5 - 4 POLE SWITCH (CX4)SHOWN WITH OPTIONAL VOLTAGE POLE 101A-175A DEVICE, 600VDC Notes: 1 All dimensions are in inches [millimeters]. 2 3 pole configuration supplied with voltage coil on pole 1. Optional location pole 3. Consult factory. 3 5 pole configuration supplied with voltage coil in center pole. (Pole 3) 4 Line & Load connections requires bus connection as shown. Minimum cross selection .127 in2 (81.94 mm2) Email:...

Open the catalog to page 9

All Carling Technologies catalogs and technical brochures

  1. 641-Series

    6 Pages

  2. Marine Catalog

    190 Pages

  3. H-Series

    14 Pages

  4. Carling GFCI

    29 Pages

  5. VP-Series

    6 Pages

  6. W-Series

    10 Pages

  7. R135-Series

    2 Pages

  8. ST-Series

    8 Pages

  9. C-Series

    4 Pages

  10. D-Series

    4 Pages

  11. DK-EK-Series

    4 Pages

  12. F-Series

    4 Pages

  13. G-Series

    4 Pages

  14. H-I-Series

    4 Pages

  15. LT-Series

    4 Pages

  16. BD-Series

    10 Pages

  17. TB-Series

    6 Pages

  18. PB-Series

    12 Pages

  19. PC-Series

    14 Pages

  20. V-Charger

    6 Pages

  21. ROCKER SWITCHES

    176 Pages