Power Distribution AC & DC Power Distribution and Battery Disconnects
Open the catalog to page 1Carling Technologies' Introduction to Power Distribution With over 80 years of experience in the development of power switching and protection components, Carling Technologies offers standard and custom designed AC and DC power distribution centers that provide the utmost in safety, reliability and performance. Power Distribution Center, or PDC, is Carling's term for a standard or custom power distribution panel or unit that's factory wired and contains overcurrent and short circuit protection devices. It may also contain auxiliary devices such as surge suppressors, ground fault circuit interrupters,...
Open the catalog to page 2Custom Power Distribution Solutions Power Distribution Project Design Form
Open the catalog to page 3Carling Technologies' LDM1-Series DC Secondary Power Distribution LDMI-Series: 19” or 23” One Rack Unit The LDMI-Series One Rack Unit (1RU) saves valuable real estate on a rack, while offering ease of installation and service. To help conserve valuable cabinet space, Carling Technologies introduces a new, advanced 1RU DC Power Distribution Unit (PDU) for the telecom industry. This new PDU is designed to fit industry standard 19” rack systems. This 1RU is listed to UL/CUL 1801 and designed to EN60950. The Carling circuit breakers installed in the 1RU are the miniature M-Series hydraulic-magnetic...
Open the catalog to page 4Carling Technologies" LDMI-Series DC Secondary Power Distribution LDMI-Series Ordering Scheme20 10 01 03 25 15 H7 5 Breaker in Position 2 Breaker in Breaker in Breaker in Series Rocker Delay Breaker in 4 through 12 BREAKER RATING 00 No breaker 01 1 amp 13 APPROVALS A No approvals G UL/CUL J UL/CUL, CE, TUV NOTES: Redundant feed. Breaker layout will be duplicated on the second feed. Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed. A panel plug will be supplied in the breaker positions that do not have a circuit breaker selected....
Open the catalog to page 5Carling Technologies' LDM1-Series DC Secondary Power DistributionCircuit BreakersCircuit breakers can be ordered separately to upgrade or reconfigure panel at a later date. Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory.General Specifications: UL/CUL and TUV approved STANDARD TRIP, MEDIUM DELAY, CURVE #14 M-SERIES TIME DELAY VALUES Circuit Breakers Dimensional Specifications STUD PANEL THICKNESS SOCKET MOUNT WITH FRONT PANEL ACCESS FOR ROCKER PUSH-IN STUD MATING HOLE
Open the catalog to page 6Carling Technologies' LDCI-Series DC Secondary Power Distribution LDCI-Series:19” or 23” One Rack Unit To help conserve valuable panel space, Carling Technologies introduces a new 1RU DC Power Distribution Unit (PDU) for the telecom industry. This new PDU is designed to fit industry standard 19” rack systems. The 1RU is listed to UL/CUL 1801 and designed to EN60950. The Carling circuit breakers installed in the 1RU are plug in style to allow for hot swapability and front access, and are rated to 50 amps per pole with a standard 10,000 amp interrupting capacity rating and a special 50,000 amp...
Open the catalog to page 7Carling Technologies' LDC1-Series DC Secondary Power Distribution LDCl-Series Ordering Scheme Series Breaker Delay Breaker in Breaker in Breaker in Breaker in Breaker in Breaker in Approvals 2 BREAKER FUNCTION N No breaker S Mid-Trip 4 through 9 BREAKER RATING 20 3 DELAY N No breaker L Medium Delay, Curve 16 M Medium Delay, Curve 14 10 APPROVALS A No approvals G UL/CUL NOTES: Redundant feed. Breaker layout will be duplicated on the second feed. Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed. GREEN LED INDICTIONS...
Open the catalog to page 8Carling Technologies' LDC2-Series DC Secondary Power Distribution LDC2-Series: 23” One Rack Unit To reduce space within Telecom cabinets without sacrificing power, Carling Technologies has introduced a versatile 1RU power distribution unit that combines GMT fuse protection with hydraulic-magnetic circuit breaker protection. This new LDC2-Series panel is designed to fit industry standard 23” rack systems. The LDC2-Series panel features powerful dual feed redundancy for both the circuit breakers and the fuses. Hot “swappable” design allows the panel to be field or factory configured, and upgraded....
Open the catalog to page 9Carling Technologies' LDC2-Series DC Secondary Power DistributionLDC2-Series Ordering Scheme 1 SERIES LDC2 4 through 9 BREAKER RATING 2 BREAKER FUNCTION N No breaker S Mid-Trip A Standard Trip 3 DELAY N No breaker L Medium Delay, Curve 16 M Medium Delay, Curve 14 10 through 13 FUSE RATING Z A B C D E UL/CUL J UL/CUL, CE, TUV NOTES: Redundant feed. Breaker layout will be duplicated on the second feed. Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed. GMT fuse feeds A& B are rated for 40 amps each. Total combined fuse ratings can not exceed...
Open the catalog to page 10Carling Technologies LDC1 & LDC2-Series Power Distribution Breakers ™ Circuit Breakers Circuit breakers can be ordered separately to upgrade or reconfigure panel at a later date. Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory. General Specifications: UL489, CSA and VDE approved 10,000 amp interrupting capacity C-SERIES TIME DELAY VALUES PERCENT OF RATED CURRENT TRIP MEDIUM DELAY, CURVE #14 RATING (amps) STANDARD TRIP D.C. MEDIUM DELAY CURVE NO. 14 TRIP TIME IN SECONDS STANDARD TRIP LONG DELAY, CURVE #16 RATING (amps) PERCENT OF RATED CURRENT...
Open the catalog to page 11LAC1-Series Telecom AC Power Distribution Panel ^- LAC1-Series: Telecom AC PDC The IAC1-Series AC PDC provides custom configurations in a standard format. The LAC1-Series eliminates the need to invest in custom designed AC power requirements. The LACI-Series is a standard AC load center designed for today’s Telecommunications requirements, and is available from 120-240VAC. General Specifications Features & Benefits Standards: Dimensions: Enclosure: Mains Breaker: Loads: Service Outlet: Operating Voltage: Service Entry: Load Center Breakers: UL67 Listed for AC Panelboards Wall mount enclosure. 20”W...
Open the catalog to page 1214 Pages
6 Pages
174 Pages
190 Pages
8 Pages
14 Pages
10 Pages
12 Pages
202 Pages
26 Pages
20 Pages
28 Pages
29 Pages
4 Pages
4 Pages
14 Pages
14 Pages
6 Pages
10 Pages
4 Pages
2 Pages
10 Pages
4 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
10 Pages
20 Pages
6 Pages
12 Pages
14 Pages
6 Pages
176 Pages
114 Pages
4 Pages
64 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
172 Pages
84 Pages
18 Pages
28 Pages