Catalog excerpts

BD-SERIES BD-Series BATTERY DISCONNECT POWER SWITCH Carling Technologies BD-Series battery disconnect switch is designed to minimize battery drain, ensure maintenance personnel safety, and when used in conjunction with a padlock, provide vehicle theft protection. Resources: Download 3D CAD Files Watch Product Video Product Highlights: 100-250 Amps 12VDC/24VDC IP67 Sealing Protection Lock Compatible Typical Applications: On/Off-Highway Equipment Military Marine 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231
Open the catalog to page 1
2 | BD-Series Battery Power Switch - Design Features DESIGN FEATURES SHAFT SEALS SLIDING CONTACT BODY SEAL ROTARY KNOB LOCK COMPATIBLE Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.co
Open the catalog to page 2
BD-Series Battery Power Switch - General Specifications | 3 Electrical Application Voltage Mechanical DC Free drop Rated voltage: 12VDC /24VDC Range of operating voltage: 12VDC: min 9VDC, max 16VDC; Endurance 24VDC: min 18VDC, max 32VDC No damage after 3 drops from 1000 mm height More than 100,000 cycles without load Current Ratings Environmental Operating Temp. -40 °C to +85 °C. Intermittent Current Dielectric Strength Insulation Resistance Temperature rise 1500A: 3 seconds on, 60 seconds off @24VDC,1500A, repeated 10 times, voltage drop should not be more than 400mV between...
Open the catalog to page 3
4 | BD-Series Battery Power Switch - Ordering Scheme & Dimensional Specifications Rating Termination "0N/0FF" SINGLE POLE SINGLE THROW SWITCH CIRCUIT DIAGRAM Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com
Open the catalog to page 4
BD-Series Battery Power Switch - Mounting Method 1 | 5 MOUNTING STEP 1: PUT THE MOUNTING GASKET WITH THE SW ITCH ORIENTATION AS SHOWN MOUNTING STEP 2: ORIENT AS SHOWN AND INSTALL THE SWITCH IN MOUNTING PANEL HOLE; THEN INSERT STUDS AND WASHERS AS SHOWN, MOUNTING PANEL MOUNTING STEP 3: TIGHTEN 2PCS M8 NUTS (USE TORQUE [10-15Nm]) Notes: 1 Switch can be mounted horizontally or vertically.
Open the catalog to page 5
6 | BD-Series Battery Power Switch - Mounting Method 2 MOUNTING STEP 1; INSTALLING SWITCH WITH MOUNTING BRACKET ORIENTATION AS SHOWN MOUNTING STEP 2: ORIENTAT AS SHOWN AND INSTALL THE SWITCH ASSY IN CUSTOMER PANEL. Notes: 1 Switch can be mounted horizontally or vertically.
Open the catalog to page 6
BD-Series Battery Power Switch - Wiring | 7 WIRING 2: ATTACH 2PCS M10 "0" RING TERMINALS AS SHOWN, THEN RE-FASTEN WASHERS AND NUTS; WHEN USED IN CONJUNCTION WITH A PAD CDCK, SWITCH CAN BE LOCKED IN THE "OFF" POSITION TO PROVIDE SECURITY AND SAFETY WIRING 3: TIGHTEN 2PCS BRASS M10 NUTS (USE TORQUE [6-8Nm])
Open the catalog to page 7
Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.co
Open the catalog to page 8
Sales Representatives, Distributors & Company Profile | 9 Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and...
Open the catalog to page 9
Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: sales@carlingtech.com Northern Region Sales Office: nrsm@carlingtech.com Southeast Region Sales Office: sersm@carlingtech.com Midwest Region Sales Office: mrsm@carlingtech.com West Region Sales Office: wrsm@carlingtech.com Latin America Sales Office: larsm@carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int +...
Open the catalog to page 10All Carling Technologies catalogs and technical brochures
-
V-Series CONTURA SWITCHES
14 Pages
-
641-Series
6 Pages
-
Military Catalog
174 Pages
-
Marine Catalog
190 Pages
-
L-Series Circuit Breaker
8 Pages
-
H-Series
14 Pages
-
D-Series Circuit Breaker
10 Pages
-
CX-Series Circuit Breaker
12 Pages
-
Carling CB Catalog
202 Pages
-
C-Series Circuit Breaker
26 Pages
-
B-Series Circuit Breaker
20 Pages
-
A-Series Circuit Breaker
28 Pages
-
Carling GFCI
29 Pages
-
On-Off Highway Industry
4 Pages
-
Military Industry
4 Pages
-
V-Series-Contura-X-XI-XII
14 Pages
-
V-Series-Contura-XIV
14 Pages
-
VP-Series
6 Pages
-
W-Series
10 Pages
-
700-800-Series
4 Pages
-
R135-Series
2 Pages
-
V-Series-Rotary
10 Pages
-
110-216-Series
4 Pages
-
ST-Series
8 Pages
-
C-Series
4 Pages
-
D-Series
4 Pages
-
DK-EK-Series
4 Pages
-
F-Series
4 Pages
-
G-Series
4 Pages
-
H-I-Series
4 Pages
-
LT-Series
4 Pages
-
MAAOA-215-Series
4 Pages
-
Carling Thermal CB
20 Pages
-
TB-Series
6 Pages
-
PB-Series
12 Pages
-
PC-Series
14 Pages
-
V-Charger
6 Pages
-
ROCKER SWITCHES
176 Pages
-
On-Off Highway Catalog
114 Pages
-
Telecom-Datacom Industry
4 Pages
-
Renewable Energy
64 Pages
-
Renewable Energy Industry
4 Pages
-
Medical Equipment Brochure
4 Pages
-
On/Off Highway Brochure
4 Pages
-
Renewable Energy Brochure
4 Pages
-
Marine Brochure
4 Pages
-
Telecom/Datacom Brochure
4 Pages
-
Military Brochure
4 Pages
-
Switches & Controls
172 Pages
-
Miniature Switches
84 Pages
-
Thermal Circuit Protection
18 Pages
-
GFCI/ELCI Circuit Protection
28 Pages