energy saving solutions for data centers

energy saving solutions for data centers

energy saving solutions for data centers

Product catalog summary
Overview
Carel provides climate solutions focusing on evaporative cooling, adiabatic humidification, and programmable controllers aimed at energy savings in data centers. These solutions are designed to reduce energy consumption while maintaining optimal operating conditions for IT equipment.

Energy Saving Solutions
Carel's solutions offer significant energy savings, with a global energy saving of 68 kW for every 100 l/h of evaporated water. These solutions are applicable to both new installations and retrofits, enhancing the Power Usage Effectiveness (PUE) of existing data centers.

Data Center Air-Conditioning
Data centers consume approximately 30 GW of power globally, representing 1.5% of total electricity usage. Carel's solutions include Computer Room Air Conditioners (CRAC) and Close Control Units (CCU) that cool and humidify air efficiently. The use of air handling units for free cooling and adiabatic humidifiers further reduces energy consumption.

Evaporative Cooling and Adiabatic Humidification
These techniques are environmentally friendly and reduce power consumption. The solutions include direct and indirect evaporative cooling (DEC and IEC), which optimize the use of outside air and control humidity effectively.

System Configurations
  • Direct Free Cooling + DEC: Utilizes outside air for cooling, with DEC providing additional cooling when conditions allow.
  • Indirect Air-Side Free Cooling + IEC: Recirculates air through a heat recovery unit, avoiding contaminants and maximizing cooling efficiency.
  • Indirect Free Cooling + IEC with CRAC: Combines IEC with traditional CRAC units for retrofits, ensuring redundancy and precise humidity control.
  • Indirect Water-Side Free Cooling + IEC: Extends free cooling periods and reduces energy consumption by lowering condensing pressure.


Technological Components
  • pCO: Manages AHU components and controls temperature and humidity.
  • VFD Inverter: Modulates air volume to minimize energy consumption.
  • humiFog and optiMist: Ensure precise humidity control and energy savings.
  • ChillBooster: Enhances cooling efficiency by lowering refrigerant circuit temperatures.


Conclusion
Carel's climate solutions for data centers focus on maximizing energy efficiency and reducing environmental impact through advanced cooling and humidification technologies. These solutions are adaptable to various data center configurations and requirements, ensuring reliable and efficient operation.
See more

Catalog excerpts

energy saving solutions for data centers-1

Climate solutions evaporative cooling, adiabatic humidification and programmable controllers energy saving solutions for data centers

 Open the catalog to page 1
energy saving solutions for data centers-2

Data center air-conditioning Data center air-conditioning is essential for the correct operation of Information Technology equipment: processing and storage devices produce considerable heat that needs to be removed in order to maintain optimum operating conditions. Energy saving through evaporative cooling and adiabatic humidification: integration and versatility Worldwide data center power consumption is estimated to be 30 GW, accounting for around 1.5% of the earth’s total electricity usage: as a result of this astonishing level of energy consumption, energy saving solutions are increasingly...

 Open the catalog to page 2
energy saving solutions for data centers-3

Evaporative cooling and adiabatic humidification The data center air-conditioning solution with the highest energy efficiency and lowest environmental impact evaporative cooling and eliminating inefficiencies. The outside air condition where mechanical cooling only is required is represented by the red area. Evaporative coolers, such as water spray atomizers, provide highly efficient cooling solutions with the added benefit of humidity control whilst ensuring substantial reduction in energy consumption and costs without any impact on maintenance costs. 90 Optimum control of the air80 conditioning...

 Open the catalog to page 3
energy saving solutions for data centers-4

Direct free cooling + DEC and adiabatic humidification The solution that optimises the use of outside air, lowering temperatures in summer through direct evaporative cooling (DEC) and controlling humidity in winter, using the same unit Maximum free cooling and DEC efficiency Extension of the period in which free cooling can be used Precise humidity control The system comprises an AHU that introduces outside air in summer for free cooling, plus DEC when the outside conditions allow. The air is humidified and cooled providing approx. 680W/L cooling with a power consumption from just 4W/L. This...

 Open the catalog to page 4
energy saving solutions for data centers-5

Indirect air-side free cooling + IEC The solution that maximises free cooling, implementing indirect evaporative cooling without introducing outside air into the data center due to problems such as pollutants, or when humidity levels mean DEC is not feasible The system comprises an AHU that recirculates the air, cooling it via a heat recovery unit that exchanges heat with the outside air. This “secondary” air stream flows through the heat recovery unit without entering the data center. The evaporative cooler (2) reduces the “secondary” air temperature, while at the same time increasing its humidity...

 Open the catalog to page 5
energy saving solutions for data centers-6

Indirect free cooling + IEC combined with CRAC The solution involving IEC combined with traditional air-conditioning technology using perimeter Computer Room Air Conditioners Air recirculation to avoid introducing contaminants Ideal solution for retrofits in existing data centres Humidity control with adiabatic humidification Redundancy with two separate systems The system comprises an AHU that recirculates the air, cooling it via a heat recovery unit that exchanges heat with the outside air. This “secondary” air stream flows through the heat recovery unit without entering the data center. The...

 Open the catalog to page 6
energy saving solutions for data centers-7

Indirect “water-side” free cooling + IEC The solution for saving energy through evaporative cooling, however without modifying the air flows inside the data center, using traditional air-conditioning technology The system comprises perimeter CRAC units that control supply or server room temperature and humidity. chillBooster, installed on the dry cooler or the condenser, evaporatively cools the air intake and guarantees considerable energy saving by lowering the average refrigerant circuit condensing temperature. In CRAC systems with water-side economizers, i.e. fitted with a water coil that...

 Open the catalog to page 7
energy saving solutions for data centers-8

Steam humidification kit for close control units Controller for compressors with permanent magnet brushless motors (BLDC/BLAC). humiSonic Ultrasound humidification for close control units and fan coils Optimist Air can be effectively cooled by exploiting the evaporation of atomised water. 100 kg/h of water absorbs 69 kW of heat when evaporating, with power consumption of less than 1 kW. Inverters represent a cutting-edge solution for modulating fan speed. Flexibility, connectivity, integration, energy saving. Adiabatic humidifiers offer significant advantages in terms of precise and efficient...

 Open the catalog to page 8

All CAREL catalogs and technical brochures

  1. pLoads

    2  Pages

  2. ChillBooster

    4  Pages

  3. pGD touch

    8  Pages

  4. pCO sistema+

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.