video corpo

WSD12-EVTT IM
1 /6Pages

WSD12-EVTT IM

WSD12-EVTT IM
1 /6Pages

Catalog excerpts

WSD12-EVTT IM-1

WSD12-EVTT Installation Manual 1 - Description The datalogger WSD12-EVTT is a probe for the measure of Thermal energy, Fluid Volume and double temperature to contact, with functionality of recording and transmission of the carried out surveys. The datalogger interfaces with the pulse output of thermal energy counters installed on the system to be monitored. The contact sensor that measures the temperature of the heat-transfer fluid, must be fixed to the sent tube or in a sump. Eventually, hose clamps and siliconic grease may be used between surfaces. To improve the quality of the sample the contact surface an insulator coverage may be useful. Contact Sensor CH3 Contact Sensor CH4 2 - Installation Mode It is necessary to verify the setup regarding the weight expressed in Wh and Litres matching the impulse supplied from the energetic counter to which the probe is wanted to be connected. Refer to the technical card of the energy meter. In order to select the weights, act on the “dip switches” located in the inner electronic board. To verify the correct range setup please refer to the table below. NOTE: in order that the modification take effect, the association between datalogger and the receiving basestation is necessary. If the sensor were already associate, so reset and reassociate operations must be done. (refer to “WineCapManager User Manual”) Pulse weight setup: ON WA0304E_R01-WSD12-EVTT IM CAPETTI ELETTRONICA s.r.l. - Strada Stratta, 57 (formerly via Colombo) 10090 CASTIGLIONE TORINESE - TORINO - ITALIA VAT 04837130014 - Phone 011.981.98.11 - Fax 011.981.98.210 e-mail [email protected] - web www.capetti.it

 Open the catalog to page 1
WSD12-EVTT IM-2

WSD12-EVTT Installation Manual 3 - Probe preset and use mode. Wireless Mode: no setup operation is needed. Typically the system is configured from factory so the probe is already associated to the system basestation. If the probe is in STANDBY mode, it must be started with the TEST command (refer chapter 4 - Wireless setup). Otherwise, in case the probe is in FACTORY RESET mode, that means it's ready for connecting to an existing system, in order to associate it to it to make reference to the “WineCapManager” software manual. Is necessary to use the "WineCapManager" software on the PC connected...

 Open the catalog to page 2
WSD12-EVTT IM-3

WSD12-EVTT Installation Manual The datalogger will give back the radio signal quality through led flashes: Optimize reception selecting the best position: small movements can help. If the signal is absent or insufficient at the install point, a WR11 router should be put between (refer to " WineCapManage?' User Manual). The router itself must be located in a position where the signal level is at least sufficient. The network will reconfigure itself automatically; the signal will be good again when the probe synchronizes with the router. The link will not be reconfigured until completely lost by...

 Open the catalog to page 3
WSD12-EVTT IM-4

WSD12-EVTT Installation Manual STATUS Table: 6 - Shutting off/Reactivating the datalogger If the device is shut off and left unused for a long time, you can issue the STANDBY command. Its corresponds to the command number 4 and must be issued twice to confirm the operation. Verify the double flash of the red led. To reactivate the datalogger the TEST command must be issued. 7 - Technical Information Power Supply: Internal lithium battery Sampling interval: Selectable from 1 minute to 7 days Radio range: 300m on sight Dimensions: 120 x 90 x 50 mm Case material: ABS External sensor: NTC 10Kohm T...

 Open the catalog to page 4
WSD12-EVTT IM-5

F: Fixing points – 6mm insert F WA0304E_R01-WSD12-EVTT IM CAPETTI ELETTRONICA s.r.l. - Strada Stratta, 57 (formerly via Colombo) 10090 CASTIGLIONE TORINESE - TORINO - ITALIA VAT 04837130014 - Phone 011.981.98.11 - Fax 011.981.98.210 e-mail [email protected] - web www.capetti.it

 Open the catalog to page 5
WSD12-EVTT IM-6

WSD12-EVTT Installation Manual 9 - Norms of reference - EN 61010 -1 For the electromagnetic compatibility - EN 61000 - 3 - 2 This symbol indicates that this product is compliant with the European Directive 2011/65/CE that restricts the use of substances in the manufacturing of electronic devices. The "WEEE" logo on the label indicates that this product is compliant with the "WEEE" EC Directive.This symbol (valid only in the European Union countries) indicates that the product it is applied to, MUST NOT be discarded with ordinary household or industrial waste, but must be sent to an...

 Open the catalog to page 6

All Capetti Elettronica catalogs and technical brochures

  1. WSD02-TT10K

    1  Page

  2. WSD12-TT10K

    1  Page

  3. WSD12T-DD

    3  Pages

  4. WSD12-4VW

    3  Pages

  5. WSD04T-T100

    1  Page

  6. WSD04T-T1K

    1  Page

  7. WSD02T-KK

    1  Page

  8. WSD02TH-AV

    2  Pages

  9. WSD04TH

    1  Page

  10. WR12

    1  Page

  11. WSD12PB-THEE

    2  Pages

  12. MWLI-MB

    2  Pages

  13. MWDG-4DI-GSM

    2  Pages

  14. MWDG-ETH-B

    2  Pages

  15. WSS10T

    1  Page

  16. WSS02T-T100

    1  Page

  17. WSD12-EVTT

    1  Page

  18. WSD12-CC

    1  Page

  19. WSD02-PQ

    1  Page

  20. WSD12-PQPQ

    1  Page

  21. WSD12-4P

    1  Page

  22. WSD15TIIDR IM

    5  Pages

  23. WSD15TIIDR

    1  Page

  24. WSD12T-Ex

    1  Page

  25. WSD12-VW IM

    4  Pages

  26. WSD12-VW

    1  Page

  27. WSD12T-IIDR

    1  Page

  28. WSD12PS-4AI

    1  Page

  29. WSD00TH

    1  Page

  30. WSD02T-TT1K

    1  Page

  31. WSD02T-T1K

    1  Page

  32. WSD02T-T100

    1  Page

  33. WSD02T-TT100

    1  Page

  34. WSD15TIDR(A)

    1  Page

  35. WSD15TIIDRO

    1  Page

  36. WSD12-PQ

    1  Page

  37. WSD12-LVD

    1  Page

  38. WSD12T-AVMS1

    1  Page

  39. WSD12-THEE

    1  Page

  40. WSD12-TT1K

    1  Page

  41. WSD02T-DD

    1  Page

  42. WSD04T

    1  Page

  43. WSD02-TT1K

    1  Page

  44. WSD02TH-DD

    1  Page

  45. WSD02-CC

    1  Page

  46. WSD00LP

    1  Page

  47. WSD10TGII

    1  Page

  48. WSD12-4DI

    1  Page

  49. WSD10MiGG

    1  Page

  50. WSD00TH2

    1  Page

  51. WSD00TH2CO

    1  Page

  52. WSD00TH2L

    1  Page

  53. WSA02Rx

    1  Page

  54. WST02TS(A)

    2  Pages

  55. SD12-VW

    1  Page

  56. SD15TIIDR

    1  Page

  57. SD02T-T100

    1  Page

  58. SD02T-TT100

    1  Page

  59. SD04T-T100

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.