Group: Capacitec Us
Catalog excerpts
AB HPC- 75 Cylindrical Probe Temperature Ranges A and E Specifications Temperature Ranges: Temperature Range A Low: 32º F [0º C] High: 302º F [150º C] Temperature Range E Low: -100º F [-73º C] High: 400º F [205º C] Guard Case Linear Range: 0.050 inches [1.27 millimeters] with a 5 foot [1.52 meters] long Capacitec L2 cable. For cables longer than 5ft consult factory. Sensor Maximum Range: 0.075 inches [1.91 millimeters] Calibration: A 20 point archived calibration record of voltage output versus nominal displacement is provided standard with every probe. Several NIST traceable calibrations are available. Material: Case, guard, and sensor are 303 stainless steel Driven Guard: The guard element is driven with an electronic voltage of 2V to 20V peak to peak. Note, the guard must not be grounded. Dip Coating: "-D" epoxy dip coatings are optional to prevent accidental earth grounding or shorting of the elements. Mounting: Probe is designed to be mounted into a 0.250 (1/4) +0.001/-0.000 inch diameter hole. It is usually held in place with a set screw. Distance to target is adjusted by sliding the probe to the desired distance from the target and locking it in place with the set screw. Cable: Coaxial Capacitec L2 or L3 cable is standard. Probe must be calibrated with the cable type and length selected. Cable must not be cut or spliced. Probe Lengths: There are 3 standard probe lengths, and 6 non-standard probe lengths. See drawing for dimensions. US Email: sales@capacitec.com EU Email: eurosales@capacitec.com Web: www.capacitec.com
Open the catalog to page 1AB HPC- 75 High Temperature Cylindrical Probe Temperature Ranges V and S Specifications Temperature Ranges: Cable Temperature Range V Low: -100º F [-73º C] High: 1600º F [871º C] Temperature Range S Low: -100º F [-73º C] High: 1832º F [1000º C] Linear Range: 0.050 inches [1.27 millimeters] with a 5 foot [1.52 meters] long Capacitec T cable. For cables longer than 5ft consult factory. Maximum Range: 0.075 inches [1.91 millimeters] Calibration: A 20 point archived calibration record of voltage output versus nominal displacement is provided standard with every probe. Several NIST traceable...
Open the catalog to page 2CABLE TYPE CABLE LENGTH CONNECTORTYPE
Open the catalog to page 3Standard Cylindrical Probes DIMENSIONS ARE NOMINAL VALUES CUSTOM LENGTH OPTIONS COAX CABLE
Open the catalog to page 4Standard High Temperature Cylindrical Probes DIMENSIONS ARE NOMINAL VALUES
Open the catalog to page 5All CAPACITEC catalogs and technical brochures
-
508-SW SWITCHING AMPLIFIER
2 Pages
-
520 AMPLIFIER
4 Pages
-
HPC-500
5 Pages
-
HPC-375
5 Pages
-
HPC-150
5 Pages
-
HPT-40
3 Pages
-
HPB-500
7 Pages
-
HPB-150
7 Pages
-
HPB-75
7 Pages
-
HPB-40
4 Pages
-
HPC-500
4 Pages
-
HPC-375
4 Pages
-
HPC-150
4 Pages
-
HPC-75
4 Pages
-
HPC-40
3 Pages
-
GapmanGen3 Brochure
4 Pages
-
Coater Bargrafx Software
5 Pages
-
GAPMANGEN3
4 Pages
-
Aerospace
8 Pages
-
Capteura® 200 Series System
4 Pages
-
Slot Die Coater Brochure
4 Pages
Archived catalogs
-
Disc Brake
4 Pages
-
Standard products
12 Pages