AB HPC- 500 Cylindrical Probe Temperature Ranges A and E Specifications Temperature Ranges: Temperature Range A Low: 32º F [0º C] High: 302º F [150º C] Temperature Range E Low: -100º F [-73º C] High: 400º F [205º C] Linear Range: 0.325 inches [8.26 millimeters] with a 5 foot [1.52 meters] long Capacitec L2 cable. For cables longer than 5 ft consult factory. Maximum Range: 0.500 inches [12.70 millimeters] Calibration: A 20 point archived calibration record of voltage output versus nominal displacement is provided standard with every probe. Several NIST traceable calibrations are available. Material: Case, guard, and sensor are 303 stainless steel Driven Guard: The guard element is driven with an electronic voltage of 2V to 20V peak to peak. The guard must not be grounded. Dip Coating: "-D" epoxy dip coatings are optional to prevent accidental earth grounding or shorting of the elements. Mounting: Probe is designed to be mounted into a 1.000 +0.001/-0.000 inch diameter hole. It is usually held in place with a set screw. Distance to target is adjusted by sliding the probe to the desired distance from the target and locking it in place with the set screw. Cable: Coaxial Capacitec L2 or L3 cable is standard. Probe must be calibrated with the cable type and length selected. Cable must not be cut or spliced. Probe Lengths: There are 3 standard probe lengths, and 6 non-standard probe lengths. See drawing for dimensions. US Email: [email protected] EU Email: [email protected] Web: www.capacitec.com
Open the catalog to page 1AB HPC- 500 Cylindrical Probe Temperature Ranges V and S Specifications Cable Temperature Ranges: Temperature Range V Low: -100º F [-73º C] High: 1600º F [871º C] Temperature Range S Low: -100º F [-73º C] High: 1832º F [1000º C] Linear Range: 0.325 inches [8.26 millimeters] with a 5 foot [1.52 meters] long Capacitec T cable. For cables longer than 5ft consult factory. Maximum Range: 0.500 inches [12.70 millimeters] Calibration: A 20 point archived calibration record of voltage output versus nominal displacement is provided standard with every probe. Several NIST traceable calibrations are available....
Open the catalog to page 2CABLE TYPE CABLE LENGTH CONN ECTOR TYPE
Open the catalog to page 3Standard Cylindrical Probes DIMENSIONS ARE NOMINAL VALUES CUSTOM LENGTH OPTIONS COAX CABLE
Open the catalog to page 4Standard High Temperature Cylindrical Probes DIMENSIONS ARE NOMINAL VALUES
Open the catalog to page 52 Pages
4 Pages
5 Pages
5 Pages
5 Pages
3 Pages
7 Pages
7 Pages
7 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
4 Pages
5 Pages
4 Pages
8 Pages
4 Pages
4 Pages
4 Pages
12 Pages