HPC-375-1

AB HPC- 375 Cylindrical Probe Temperature Ranges A and E Specifications Temperature Ranges: Cable Temperature Range A Low: 32º F [0º C] High: 302º F [150º C] Temperature Range E Low: -100º F [-73º C] High: 400º F [205º C] Linear Range: 0.250 inches [6.35 millimeters] with a 5 foot [1.52 meters] long Capacitec L2 cable. For cables longer than 5 ft consult factory. Maximum Range: 0.375 inches [6.35 millimeters] Calibration: A 20 point archived calibration record of voltage output versus nominal displacement is provided standard with every probe. Several NIST traceable calibrations are available. Material: Case, guard, and sensor are 303 stainless steel Driven Guard: The guard element is driven with an electronic voltage of 2V to 20V peak to peak. The guard must not be grounded. Dip Coating: "-D" epoxy dip coatings are optional to prevent accidental earth grounding or shorting of the elements. Mounting: Probe is designed to be mounted into a 0.750 (3/4) +0.001/-0.000 inch diameter hole. It is usually held in place with a set screw. Distance to target is adjusted by sliding the probe to the desired distance from the target and locking it in place with the set screw. Cable: Coaxial Capacitec L2 or L3 cable is standard. Probe must be calibrated with the cable type and length selected. Cablemust not be cut or spliced. Probe Lengths: There are 3 standard probe lengths, and 6 non-standard probe lengths. See drawing for dimensions. US Email: [email protected] EU Email: [email protected] Web: www.capacitec.com

 Open the catalog to page 1
HPC-375-2

AB HPC-375 Cylindrical Probe Temperature Ranges V and S Specifications Temperature Ranges: Temperature Range V Low: -100º F [-73º C] High: 1600º F [871º C] Temperature Range S Low: -100º F [-73º C] High: 1832º F [1000º C] Linear Range: 0.250 inches [6.35 millimeters] with a 5 foot [1.52 meters] long Capacitec T cable. For cables longer than 5ft consult factory. Case Sensor Maximum Range: 0.375 inches [6.35 millimeters] Calibration: A 20 point archived calibration record of voltage output versus nominal displacement is provided standard with every probe. Several NIST traceable calibrations are...

 Open the catalog to page 2
HPC-375-3

CABLE TYPE CABLE LENGTH

 Open the catalog to page 3
HPC-375-4

Standard Cylindrical Probes DIMENSIONS ARE NOMINAL VALUES COAX CABLE

 Open the catalog to page 4
HPC-375-5

Standard High Temperature Cylindrical Probes DIMENSIONS ARE NOMINAL VALUES

 Open the catalog to page 5

All CAPACITEC catalogs and technical brochures

  1. 520 AMPLIFIER

    4  Pages

  2. HPC-500

    5  Pages

  3. HPC-150

    5  Pages

  4. HPC-75

    5  Pages

  5. HPT-40

    3  Pages

  6. HPB-500

    7  Pages

  7. HPB-150

    7  Pages

  8. HPB-75

    7  Pages

  9. HPB-40

    4  Pages

  10. HPC-500

    4  Pages

  11. HPC-375

    4  Pages

  12. HPC-150

    4  Pages

  13. HPC-75

    4  Pages

  14. HPC-40

    3  Pages

  15. GAPMANGEN3

    4  Pages

  16. Aerospace

    8  Pages

Archived catalogs

  1. Disc Brake

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.