video corpo

NEMA Premium Efficiency Motors SIE series
40Pages

{{requestButtons}}

Catalog excerpts

NEMA Premium Efficiency Motors SIE series - 1

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS NEMA PREMIUM including motors for JM/JP close coupled pumps and for Hazardous Locations PROFESSIONAL DRIVING INTO YOUR MORE ENERGY PROFESSIONAL SERVICE ENERGY GLOBAL IDEA TURNED INTO ENERGY BUSINESS GLOBAL DEVELOP CHALLENGING PROJECTS INDIVIDUAL PROF MORE ENERGY Product Catalogue

Open the catalog to page 1
NEMA Premium Efficiency Motors SIE series - 2

Product range LOW VOLTAGE GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Three-phase motors with squirrel-cage rotor series (2)Sg(m), Sh. GENERAL PURPOSE 1-PHASE INDUCTION MOTORS HIGH VOLTAGE INDUCTION MOTORS UP TO 11kV for general purpose applications like pumps, fans, compressors; complying with the newest efficiency requirements Single-phase motors with squirrel-cage rotor series SEh(R), SEMh(R). – motors with standard starting torque – motors with increased starting torque – motors with high starting torque. for general purpose applications like pumps, fans, compressors, woodworking machines,...

Open the catalog to page 2
NEMA Premium Efficiency Motors SIE series - 4

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Efficiency of motors in the USA USA began to regulate efficiency of electric motors in 1992 with the “Energy Efficiency Provision” of the Energy Policy Act (EPAct). In 1997, USA was the first country in the world to establish minimum energy performance standards (MEPS) for electric motors manufactured in or sold to USA. Generalpurpose motors 1HP-200HP were required to meet NEMA Energy Efficient standard (EPACT). In June 2016, efficiency standards in the USA were increased once again with the Integral Horsepower Motor Rule (IHMR) which superseded the...

Open the catalog to page 4
NEMA Premium Efficiency Motors SIE series - 5

Ratings – Tolerances Tolerances of motor parameters Permissible deviations between catalogue values and real values: Power factor cos φ NEMA PREMIUM minimum according to NEMA MG-1 Locked rotor current ratio IL/IN Locked rotor torque ratio TL/TN Breakdown torque ratio TB/TN Sound pressure level LpA [dB] Tolerances of supply voltage value and frequency Motors comply in standard with voltage value and voltage frequency variations according to the NEMA MG-1: Voltage value U Other extended tolerances of supply voltage and their frequency are available on request. Standards Depending on the...

Open the catalog to page 5
NEMA Premium Efficiency Motors SIE series - 6

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Insulation classification The insulation system of an electric motor is determined by a given insulation class on the basis of its thermal resistance. This thermal resistance should be guaranteed by the entire set of electric insulating materials used in the motor insulating system. Thermal resistance classification is related to the temperature of the hotspot in the insulation occurring during rated operating conditions of the electric motor, allowing for the highest permissible rise in average temperature. This rise should be selected so that at...

Open the catalog to page 6
NEMA Premium Efficiency Motors SIE series - 7

Hazardous Locations Classification Our NEMA PREMIUM motors can be delivered in special execution for Hazardous Locations and are certified for Groups A, B, C, D, F and G. CLASS – Defines the type of hazardous material (explosive or ignitable substances). Class I flammable gases, vapors or liquids, such as acetylene, hydrogen, ethylene, gasoline, etc. combustible dust such as: coke dust, grain dust, etc. easily ignitable fibers or flyings, such as: textile, saw dust, etc. DIVISION – Defines the likelihood of the hazardous material being present in an explosive or ignitable concentration....

Open the catalog to page 7
NEMA Premium Efficiency Motors SIE series - 8

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Temperature Codes The T-Code identifies the maximum absolute motor surface temperature that will develop under any conditions of operation. Temperature class marking Maximum Temperature Material of housing, end shields and feet Frame size Cast iron Cast iron Cast iron – integrated Cast iron Cast iron Cast iron – integrated Motor housing Cast iron Cast iron Cast iron – integrated Cast iron Cast iron Cast iron – integrated Cast iron Cast iron Cast iron – screwed Cast iron Cast iron Cast iron – screwed Cast iron Cast iron Cast iron – screwed Cast iron...

Open the catalog to page 8
NEMA Premium Efficiency Motors SIE series - 9

Cooling General purpose motors from Cantoni Group are equipped with standard IC411 cooling. Other cooling methods (for example motors with external/separate cooling) are available on request. IC code – Fan mounted on shaft – Often called “drip-proof” motor – Surface cooled by natural convection and radiation – Without internal or external fan – Smooth or finned casing – External shaft-mounted fan – Often called TEFC motor – Smooth or finned casing – External motorized axial fan integrated with the motor – Smooth or finned casing – External motorized radial fan integrated with the motor –...

Open the catalog to page 9
NEMA Premium Efficiency Motors SIE series - 10

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Standard terminal box equipment Motor frame size Number of supply leads Number of threaded inlet holes Size of threaded inlet holes [inch] Optional rotation of terminal box Temperature sensors in the winding Thermal protection of bearings Vibration level The rotors balancing method guarantees that standard vibration level of motors is much lower than required for general industrial motors according to NEMA MG-1 (0.15in/s). On customer’s demand the motors can be produced with even more reduced vibration level. Vibration level in standard and reduced...

Open the catalog to page 10
NEMA Premium Efficiency Motors SIE series - 11

Terminal box The standard mounting position for NEMA motors is F1 – the terminal box is located on the left side of the motor facing the output shaft and it is equipped with 9 (size 143T...184T) or 12 (size 213T...447T) supply leads (without terminal block). Our NEMA PREMIUM motors are also available with terminal box on right side (F2) or on top (F3). As standard, motors are offered with aluminium terminal box for sizes 143–286, and cast iron for sizes 320–440. As optional execution, for sizes 143–286 can be also cast iron terminal box. Basic Connection Diagrams Connection diagram of...

Open the catalog to page 11
NEMA Premium Efficiency Motors SIE series - 12

General Purpose 3-phase Induction Mo General Purpose 3-phase General Purpose 3-phase General Purpose 3-phase Induction Mo INTERNATIONAL PROTECTION MARKIN INTERNATIONAL PROTECTIO General Purpose 3-phase Induction Mo General Purpose 3-phase INTERNATIONAL Induction Mo INTERNATIONAL PROTECTION MARKIN General Purpose 3-phasePROTECTIO PURPOSE 3-PHASE INDUCTION MOTORS General Purpose 3-phase INTERNATIONAL PROTECTION MARKIN INTERNATIONAL Induction Mo General Purpose 3-phase General Purpose 3-phasePROTECTIO According to the IEC 60034-5to the IEC the electric motors are According standard 60034-5...

Open the catalog to page 12

All Cantoni Motor catalogs and technical brochures

Archived catalogs

  1. H2SP_AT

    8 Pages

  2. drewno

    32 Pages