1. Catalogs
  2. Cantoni Motor
  3. NEMA Premium Efficiency Motors SIE series

NEMA Premium Efficiency Motors SIE series

NEMA Premium Efficiency Motors SIE series
1 / 40 PagesView full catalog

NEMA Premium Efficiency Motors SIE series

Product catalog summary
General Information
This document provides a comprehensive overview of NEMA Premium motors, detailing specifications for various induction motors including three-phase, single-phase, high voltage, brake, and explosion-proof motors. It emphasizes efficiency standards and classifications, ensuring compliance with US and international standards.
Efficiency Standards
The document traces the evolution of motor efficiency standards in the USA, from the Energy Policy Act (EPAct) of 1992 to the current NEMA Premium Efficiency standards. Motors with outputs between 1HP and 500HP must meet these efficiency levels, determined by CSA C390-10 or IEEE Std 112-2004 standards.
Motor Specifications
Details are provided for various motor types:
  • General Purpose 3-Phase Induction Motors: 0.04kW to 2200kW for applications like pumps and compressors.
  • General Purpose 1-Phase Induction Motors: 0.04kW to 2.2kW for diverse applications.
  • High Voltage Induction Motors: Up to 11kV for industrial use.
  • Brake Motors: 0.04kW to 160kW for applications requiring immediate stopping.
  • Explosion-Proof Motors: 0.06kW to 3200kW for hazardous environments.
Standards and Compliance
The motors comply with standards such as NEMA MG-1, CSA C22.2, and UL, ensuring safety and performance in hazardous locations. Insulation classifications include class F and optional class H.
Hazardous Locations Classification
NEMA Premium motors are certified for hazardous locations, classified by class, division, and group based on hazardous material type and presence likelihood.
Additional Features
Information on motor construction, cooling methods, terminal box equipment, and protection ratings is included, along with guidelines for mounting arrangements and permissible shaft end loads.
Conclusion
This catalog serves as a detailed guide for selecting and understanding NEMA Premium motors, emphasizing efficiency, safety compliance, and industrial application suitability.
Temperature Class Marking
Indicates maximum motor surface temperature under operational conditions, ranging from T1 (450°C) to T6 (85°C).
Material Specifications
Motors' housing, end shields, and feet are made of cast iron, with variations based on frame size.
Cooling Methods
Standard motors use IC411 cooling, with other methods available upon request.
Vibration and Noise Levels
Motors have vibration levels below NEMA MG-1 standards, with options for reduced noise.
Terminal Box and Connection Diagrams
Standard terminal box is on the left (F1), with optional positions on the right (F2) or top (F3).
Protection Ratings
Manufactured with IP55 protection rating, with higher levels available upon request.
Certificate of Compliance Overview
Issued to Cantoni Motor SA, confirming compliance with ANSI/UL 1004-1 and CSA-C22.2 No. 100 standards for safety.
Product Specifications
Details specifications of three-phase JM/JP pump motors for continuous duty service.
Frequency Converter Operation
Motors designed for frequency converter supply, allowing electronic speed control.
General Purpose 3-Phase Induction Motors
Includes a detailed table of motor specifications such as rated power, speed, torque, and efficiency.
Overall and Mounting Dimensions
Dimensions for various motor types are provided for proper installation and compatibility.
Additional Information
For more details on UL certified products, users are directed to the UL Product iQ™ database.
Specifications and Parts
Lists motor parts for different frame sizes and describes components like DE shield, rotor, and bearings.
Ordering Information
Customers should specify motor type, rated output, speed, voltage, and other details when ordering.
Certifications
Cantoni Group's manufacturing plants comply with ISO 9001, ISO 14001, and OHSAS 18001 standards.
Company Background
Founded by Giampiero Cantoni, the Cantoni Group is a leading manufacturer of electric motors with a strong international presence.
Contact Information
Cantoni Motor S.A. is located in Cieszyn, Poland, with contact details provided for inquiries and support.
See more

Catalog excerpts

NEMA Premium Efficiency Motors SIE series-1

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS NEMA PREMIUM including motors for JM/JP close coupled pumps and for Hazardous Locations PROFESSIONAL DRIVING INTO YOUR MORE ENERGY PROFESSIONAL SERVICE ENERGY GLOBAL IDEA TURNED INTO ENERGY BUSINESS GLOBAL DEVELOP CHALLENGING PROJECTS INDIVIDUAL PROF MORE ENERGY Product Catalogue

 Open the catalog to page 1
NEMA Premium Efficiency Motors SIE series-2

Product range LOW VOLTAGE GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Three-phase motors with squirrel-cage rotor series (2)Sg(m), Sh. GENERAL PURPOSE 1-PHASE INDUCTION MOTORS HIGH VOLTAGE INDUCTION MOTORS UP TO 11kV for general purpose applications like pumps, fans, compressors; complying with the newest efficiency requirements Single-phase motors with squirrel-cage rotor series SEh(R), SEMh(R). – motors with standard starting torque – motors with increased starting torque – motors with high starting torque. for general purpose applications like pumps, fans, compressors, woodworking machines, devices...

 Open the catalog to page 2
NEMA Premium Efficiency Motors SIE series-4

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Efficiency of motors in the USA USA began to regulate efficiency of electric motors in 1992 with the “Energy Efficiency Provision” of the Energy Policy Act (EPAct). In 1997, USA was the first country in the world to establish minimum energy performance standards (MEPS) for electric motors manufactured in or sold to USA. Generalpurpose motors 1HP-200HP were required to meet NEMA Energy Efficient standard (EPACT). In June 2016, efficiency standards in the USA were increased once again with the Integral Horsepower Motor Rule (IHMR) which superseded the EISA...

 Open the catalog to page 4
NEMA Premium Efficiency Motors SIE series-5

Ratings – Tolerances Tolerances of motor parameters Permissible deviations between catalogue values and real values: Power factor cos φ NEMA PREMIUM minimum according to NEMA MG-1 Locked rotor current ratio IL/IN Locked rotor torque ratio TL/TN Breakdown torque ratio TB/TN Sound pressure level LpA [dB] Tolerances of supply voltage value and frequency Motors comply in standard with voltage value and voltage frequency variations according to the NEMA MG-1: Voltage value U Other extended tolerances of supply voltage and their frequency are available on request. Standards Depending on the execution,...

 Open the catalog to page 5
NEMA Premium Efficiency Motors SIE series-6

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Insulation classification The insulation system of an electric motor is determined by a given insulation class on the basis of its thermal resistance. This thermal resistance should be guaranteed by the entire set of electric insulating materials used in the motor insulating system. Thermal resistance classification is related to the temperature of the hotspot in the insulation occurring during rated operating conditions of the electric motor, allowing for the highest permissible rise in average temperature. This rise should be selected so that at the...

 Open the catalog to page 6
NEMA Premium Efficiency Motors SIE series-7

Hazardous Locations Classification Our NEMA PREMIUM motors can be delivered in special execution for Hazardous Locations and are certified for Groups A, B, C, D, F and G. CLASS – Defines the type of hazardous material (explosive or ignitable substances). Class I flammable gases, vapors or liquids, such as acetylene, hydrogen, ethylene, gasoline, etc. combustible dust such as: coke dust, grain dust, etc. easily ignitable fibers or flyings, such as: textile, saw dust, etc. DIVISION – Defines the likelihood of the hazardous material being present in an explosive or ignitable concentration. DIVISION...

 Open the catalog to page 7
NEMA Premium Efficiency Motors SIE series-8

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Temperature Codes The T-Code identifies the maximum absolute motor surface temperature that will develop under any conditions of operation. Temperature class marking Maximum Temperature Material of housing, end shields and feet Frame size Cast iron Cast iron Cast iron – integrated Cast iron Cast iron Cast iron – integrated Motor housing Cast iron Cast iron Cast iron – integrated Cast iron Cast iron Cast iron – integrated Cast iron Cast iron Cast iron – screwed Cast iron Cast iron Cast iron – screwed Cast iron Cast iron Cast iron – screwed Cast iron Cast...

 Open the catalog to page 8
NEMA Premium Efficiency Motors SIE series-9

Cooling General purpose motors from Cantoni Group are equipped with standard IC411 cooling. Other cooling methods (for example motors with external/separate cooling) are available on request. IC code – Fan mounted on shaft – Often called “drip-proof” motor – Surface cooled by natural convection and radiation – Without internal or external fan – Smooth or finned casing – External shaft-mounted fan – Often called TEFC motor – Smooth or finned casing – External motorized axial fan integrated with the motor – Smooth or finned casing – External motorized radial fan integrated with the motor – Enclosed...

 Open the catalog to page 9
NEMA Premium Efficiency Motors SIE series-10

GENERAL PURPOSE 3-PHASE INDUCTION MOTORS Standard terminal box equipment Motor frame size Number of supply leads Number of threaded inlet holes Size of threaded inlet holes [inch] Optional rotation of terminal box Temperature sensors in the winding Thermal protection of bearings Vibration level The rotors balancing method guarantees that standard vibration level of motors is much lower than required for general industrial motors according to NEMA MG-1 (0.15in/s). On customer’s demand the motors can be produced with even more reduced vibration level. Vibration level in standard and reduced execution:...

 Open the catalog to page 10
NEMA Premium Efficiency Motors SIE series-11

Terminal box The standard mounting position for NEMA motors is F1 – the terminal box is located on the left side of the motor facing the output shaft and it is equipped with 9 (size 143T...184T) or 12 (size 213T...447T) supply leads (without terminal block). Our NEMA PREMIUM motors are also available with terminal box on right side (F2) or on top (F3). As standard, motors are offered with aluminium terminal box for sizes 143–286, and cast iron for sizes 320–440. As optional execution, for sizes 143–286 can be also cast iron terminal box. Basic Connection Diagrams Connection diagram of 143T÷184T...

 Open the catalog to page 11
NEMA Premium Efficiency Motors SIE series-12

General Purpose 3-phase Induction Mo General Purpose 3-phase General Purpose 3-phase General Purpose 3-phase Induction Mo INTERNATIONAL PROTECTION MARKIN INTERNATIONAL PROTECTIO General Purpose 3-phase Induction Mo General Purpose 3-phase INTERNATIONAL Induction Mo INTERNATIONAL PROTECTION MARKIN General Purpose 3-phasePROTECTIO PURPOSE 3-PHASE INDUCTION MOTORS General Purpose 3-phase INTERNATIONAL PROTECTION MARKIN INTERNATIONAL Induction Mo General Purpose 3-phase General Purpose 3-phasePROTECTIO According to the IEC 60034-5to the IEC the electric motors are According standard 60034-5 standard...

 Open the catalog to page 12

All Cantoni Motor catalogs and technical brochures

  1. Marine Motors

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.