Catalog excerpts
Measurement solutions for nuclear safety and security. SafePoint™ Radiation Monitoring Solutions Nuclear Measurements Business Unit of AREVA
Open the catalog to page 1Visit our web site for up-to-date information & specifications.
Open the catalog to page 2SafePoint™ Radiation Monitoring Solutions Sustainable Sustainable Committed Secure Nuclear measurements are a vital component of safe and secure power reactor operation, contributing to the safety of the public, plant and personnel over the lifetime of the facility. CANBERRA, worldwide leader in nuclear measurement solutions, supplies radiation monitoring systems and software used to monitor plant processes and environment to protect worker health and assure that the working environment is safe. With the safety of plant personnel and the general public at stake, the CANBERRA family of...
Open the catalog to page 3SafePoint™ Radiation Monitoring Solutions Sustainable Cost-effective safety and compliance Our experience enables you to enhance the long-term value of your equipment by leveraging our competencies in the following areas: An organization focused on RMS – CANBERRA has its roots in the nuclear industry. Our continued commitment to RMS customers is evident by our ongoing investment in new technologies and solutions, like the SafePoint iR7040 ratemeter. Our experienced, global RMS team is mobilized to provide you with responsive, life of plant service and support. Solid QA foundation – All RMS...
Open the catalog to page 4SafePoint™ Radiation Monitoring Solutions Sustainable Extensive RMS product line – Field-proven standard products include samplers, detectors, instruments and operations-oriented software to serve as a solid core of products for designing the appropriate radiation monitoring system for your plant. Comprehensive system display and control software – CANBERRA’s software group, with extensive in-plant experience, develops, documents, and supports our RMS applications firmware and software in accordance with nuclear industry QA standards and ISO 9001. Full RMS support for the life of the plant...
Open the catalog to page 5SafePoint™ Radiation Monitoring Solutions Sustainable Comprehensive coverage for your facility The CANBERRA SafePoint RMS family is optimized for use in safety and non-safety related applications in the following areas: 1 Reactor Building 2 Fuel Building 3 Safeguard Building 4 Access Building 5 Reactor Auxiliary Building Visit our web site for up-to-date information & specifications.
Open the catalog to page 6SafePoint™ Radiation Monitoring Solutions Sustainable 1 Reactor Building: >> Dose rate monitoring for key areas including refueling bridge, incore drives, transfer tube, setdown area >> Component cooling water monitors >> Containment vent monitors >> N-16/main steam line monitors >> Reactor coolant leak rate monitoring >> Vent stack monitors 2 Fuel Building >> Area monitoring >> Air monitoring of area and ventilation >> Dose rate monitoring for key areas including fuel loading hall, fuel pool, transfer pit, new fuel pit and fuel building set down area 3 Safeguard Building >> Dose rate...
Open the catalog to page 7SafePoint™ Radiation Monitoring Solutions Sustainable Major systems and details Area Monitors Overview Area monitors are available to provide measurement, indication, alarming and recording of gamma and neutron radiation levels at various locations in the plant. These microprocessor-based monitors operate in real time, and include alarms and isolation features for high reliability. Inputs may be from scintillation detectors, GM tubes, ion chambers or gas proportional counters for neutron detection. Area Monitors vary based on types of detectors used for different applications. While legacy...
Open the catalog to page 8SafePoint™ Radiation Monitoring Solutions Sustainable Geiger Mueller Gamma Area Monitors with or without integrated check sources AM-GP100-Gamma Area Monitor and Variants Features are: >> Operating range: 0.1 uSv/hr (10 uR/hr) to 100 Sv/hr (10,000 R/hr) >> Unique Time-to-Count technique eliminates dead time and saturation effects of conventional GM tubes >> Responsive to energies between 80 keV and 3 MeV >> Leverages feature set of iR7040 Intelligent Ratemeter >> Leverages SMART Probe advantages >> Simple calibration Variants are: >> AM-GP100SI, H*10 compliant SI version Gamma Area Monitor...
Open the catalog to page 9SafePoint™ Radiation Monitoring Solutions Sustainable Area Monitors Continued Ion Chamber Gamma Area Monitors with or without integrated check sources AM-ICP100L - Xenon-filled Gamma Area Monitor with Th232 keep-alive source AM-IP100 with iR7040 Ratemeter and Ion Chamber Probe Features are: >> Provides accurate measurement of pulsed or burst radiation >> Signal chain: ICP100L detector to CF300L amplifier to iR7040 Ratemeter >> Operating range: 1 μSv/hr (100 μR/hr) to 1 Sv/hr (100 R/h) >> Energy range: 80 keV to 3 MeV >> Qualified for post-accident conditions >> Rated for harsh environments...
Open the catalog to page 10SafePoint™ Radiation Monitoring Solutions Sustainable Neutron Area Monitors AM-NP100B- BF3 Neutron Area Monitor Features are: >> Operating range: 0.1 μSv/hr (10 μR/hr) to 200 mSv/hr (20 R/hr) >> Energy range 0.025 eV to 15MeV >> Employs proven Anderson-Braun design >> Tissue equivalent >> Leverages feature set of iR7040 Intelligent Ratemeter >> Leverages SMART Probe advantages >> Integrated mounting bracket >> Simple calibration AM-NP100H- He3 Neutron Area Monitor Features are: >> Operating range: 0.1 μSv/hr (10 μR/hr) to 200 mSv/hr (20 R/hr) >> Energy range 0.025 eV to 15MeV >> Employs...
Open the catalog to page 11SafePoint™ Radiation Monitoring Solutions Sustainable Liquid and Process Monitors Overview Process/Liquid Monitors provide continuous measurement, indication, alarming and recording of liquid and gas radioactivity at various facility locations. CANBERRA offers a variety of Process Radiation Monitors employing a mix of components scaled to your needs. These high-reliability, microprocessor-based monitors operate in real time and include alarms and isolation features. Inputs are primarily from scintillation detectors. Major components include the detector shield, detector, preamplifier,...
Open the catalog to page 12All Canberra Industries catalogs and technical brochures
-
U.S. Customer Services Catalog
66 Pages
Archived catalogs
-
automated gamma spectrometer
6 Pages
-
scintillation counter
2 Pages
-
neutron detector NP Series
2 Pages
-
cryostat / Dewar vessel
1 Pages
-
Germanium Detectors Brochure
6 Pages