Overview: The document provides a detailed overview of dataloggers, emphasizing their functionality, specifications, and applications. Dataloggers are designed to measure sensors, process data, control external devices, and operate independently of AC power and human interaction. They are compatible with various communication protocols and can perform reliably under adverse conditions.
Specifications: Dataloggers vary in size and complexity, supporting different scan rates, input/output channels, analog resolution, and voltage accuracy. They are powered by a 12 Vdc source and can interface with on-site and telemetry devices. Specifications for various Campbell Scientific data loggers, including CR200X-series, CR800/CR850, CR1000, CR3000, CR5000, and CR9000X, are provided. Key specifications include battery types, current drain, and weight with and without batteries. Supported communication protocols include SDI-12, PAKBUS, Modbus, and DNP3, along with software compatibility for different versions of LoggerNet, RTDAQ, and PConnect.
Components: Key components include a keyboard display for data transfer and sensor readings, programming with CRBasic, data storage in multiple tables, and various communication protocols such as PakBus, Modbus, DNP3, TCP/IP, FTP, and SMTP.
Input/Output Connections: Dataloggers feature CS I/O ports, power and ground connections, analog inputs, continuous analog outputs, pulse counters, digital I/O ports, and switched excitation outputs. These connections facilitate measurement, communication, and power supply to sensors and peripherals.
Model Descriptions: The document describes various datalogger models, including CR800-series, CR1000, CR200X-series, CR3000, CR5000, and CR9000X, highlighting their design features, ideal applications, and base options.
Comparison Tables: Two comparison tables provide detailed specifications for smaller and larger dataloggers, covering features such as max scan rate, analog inputs, pulse counters, digital ports, communication ports, input voltage range, analog voltage accuracy, temperature range, memory, power requirements, and dimensions.
Procedures and Recommendations: Recommendations include confirming system configuration and critical specifications with Campbell Scientific before purchase. Notes highlight specific compatibility and configuration requirements for certain devices and sensors.
Standards and Compliance: All devices are CE compliant and come with a three-year warranty.
Sensor and Peripheral Compatibility: The document includes a compatibility table for sensors and peripherals with different data logger models. It covers various sensors like anemometers, barometers, GPS, pyranometers, and more. Communication peripherals such as CompactFlash, Ethernet, and modems are also listed.
Notes: Additional notes provide guidance on compatibility with non-listed devices, specific sensor requirements, and software needs for PDAs. It also mentions limitations on communication rates for certain peripherals with the CR9000X model.
See more

Catalog excerpts

Datalogger Overview-1

WHEN MEASUREMENTS MATTER

 Open the catalog to page 1
Datalogger Overview-2

Campbell Scientific dataloggers are at the center of our rugged, reliable data acquisition systems. They are known for their flexibility, precision measurements, and dependability—even in harsh, remote environments. • Measure sensors • Process data onboard • Initiate measurement and control functions based on time or event • Control external devices such as pumps, motors, alarms, freezers, and valves • Operate independently of ac power, computers, and human interaction • Use our PC support software to program the logger • Consume minimal power from a 12 Vdc source • Interface with on-site and...

 Open the catalog to page 2
Datalogger Overview-3

Input/Output Connections Input/Output Connections include analog inputs, continuous analog outputs, pulse counters, switched excitation outputs, and digital I/O ports. These connections measure, communicate with, and power sensors and peripherals. Power & Ground Connections provide power for 12 V or 5 V peripherals and grounding points for sensors and peripherals. RS-232 Serial I/O Port connects directly to a computer or to smart serial sensors. CS I/O Port connects to most of our data storage, data retrieval, and telecommunications peripherals. Analog Inputs Analog inputs measure voltage levels....

 Open the catalog to page 3
Datalogger Overview-4

Datalogger Descriptions (listed from smallest to largest) CR200X-series Datalogger/Wireless Sensor The input channel configuration of the CR200X-series dataloggers is optimal for measuring one or two sensors; these dataloggers are not compatible with channel expansion devices or thermocouples. The CR200X series uses an external power supply. • Design Features: These are our smallest and lowest-cost dataloggers. Three of the models include an internal spread spectrum radio, which allows the dataloggers to be used in wireless networks. • Ideal Applications: Wireless sensors, wind energy, rural...

 Open the catalog to page 4
Datalogger Overview-5

The CR3000 consists of a compact, integrated package with a built-in power supply, a 128 x 64 pixel backlit graphical or eight-line numeric display, and a 16-character keyboard. • Design Features: The CR3000 provides all of the CR1000's design features, as well as more channels, programmable switched current outputs, and removable terminal strips. • Ideal Applications: Eddy covariance, wind profiling, HVAC, weather stations, vehicle testing, air quality, process control, Mesonet systems, agriculture, soil moisture, Time Domain Reflectometry, water quality • Base Options: Sealed rechargeable battery,...

 Open the catalog to page 5
Datalogger Overview-8

1. To determine compatibility with devices not offered by Campbell Scientific or devices not listed on this chart, refer to the device's product brochure or manual, or contact a Campbell Scientific applications engineer. 2. Our CR200X-series and CR5000 dataloggers are only compatible with the 2-D sonic anemometer that outputs an SDI-12 signal (the WindSonic4). Although the WindSonic4 is not listed on our price lists, it may be purchased from Campbell Scientific. 3. Contact Campbell Scientific about configuration requirements for using these dataloggers with our GPS sensor. 4. User-supplied PDAs...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.