1. Catalogs
  2. CAMLogic Srl
  3. Technical datasheetPFG05

Technical datasheetPFG05
1 /5Pages

Technical datasheetPFG05

Technical datasheetPFG05
1 /5Pages

Catalog excerpts

Technical datasheetPFG05-1

VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY Terminals : male FASTON (.250 series / 6,3x0,8 mm) Housing Aluminium (powder coated) Ambient temperature Process temperature LOW TEMPERATURE versions only (PFG.../B) LOW TEMPERATURE versions only (PFG.../B) Pressure range +0,8 ... +1,1 bar 2011/65/EU (RoHS) ATEX Marking 2014/30/EU (EMC) 2014/34/EU (ATEX) 2014/35/EU (LVD) Ex II 1/2 D Ex ta/tb IIIC T85°C IP65 Da/Db Ex II 3 D Ex tc IIIB T85°C Dc (Lamp version) Via dell'Industria 12 42025 Cavriago (RE) - ITALY www.camlogic.it UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN [mm] DRAWING FROM CAD SYSTEM - REFER TO 3D MODEL FOR MISSING DIMENSION - NO MANUAL MODIFICATION ALLOWED IECEx Marking Ex ta/tb IIIC T85°C

 Open the catalog to page 1
Technical datasheetPFG05-2

VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY ROTATION CONTROL VOLTAGE CONTROL POWER SUPPLY 2x G 1/2 (BSPP) VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY Terminals : male FASTON (.250 series / 6,3x0,8 mm) Ambient temperature Process temperature Housing Aluminium (powder coated) Connection Flange - Aluminium -40 < Ta < +70 [°C] -20 < Tp < +70 [°C] LOW TEMPERATURE versions only (PFG.../B) LOW TEMPERATURE versions only (PFG.../B) Pressure range +0,8 ... +1,1 bar 2011/65/EU (RoHS) ATEX Marking 2014/30/EU (EMC) 2014/34/EU (ATEX) 2014/35/EU (LVD) Ex II 1/2 D Ex ta/tb IIIC T85°C IP65 Da/Db Ex II 3 D...

 Open the catalog to page 2
Technical datasheetPFG05-3

PSPX : stainless steel 1000 1200 Ø32: galvanized steel Ø30: stainless steel Extension with external protection PCPX : stainless steel PRSX : stainless steel Ø32: galvanized steel Ø30: stainless steel external protection PRP : galvanized steel PRPX : stainless steel Flexible extension PF : galvanized steel Via dell'Industria 12 42025 Cavriago (RE) - ITALY www.camlogic.it UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN [mm] DRAWING FROM CAD SYSTEM - REFER TO 3D MODEL FOR MISSING DIMENSION - NO MANUAL MODIFICATION ALLOWED NOTE : lenghts may slightly differ from the tables according to the type of connection,...

 Open the catalog to page 3
Technical datasheetPFG05-4

AC6 INOX AISI 304 density > 0.1 kg/dm3 AC10 INOX AISI 304 density > 0.6 kg/dm3 AC9 INOX AISI 304 density > 0.2 kg/dm3 AC7 INOX AISI 304 density > 0.3 kg/dm3 AC5L INOX AISI 304 density > 0.2 kg/dm3 AC4 INOX AISI 304 density > 0.5 kg/dm3 AC3 INOX AISI 304 density > 0.3 kg/dm3 AC12 INOX AISI 304 density > 0.4 kg/dm3 AC14 INOX AISI 304 density > 0.4 kg/dm3 AC16 INOX AISI 304 density > 0.3 kg/dm3 AC18 INOX AISI 304 density > 0.7 kg/dm3 AC17 INOX AISI 304 density > 0.4 kg/dm3 AC11 INOX AISI 304 density > 0.1 kg/dm3 AC8 galvanized steel (wires) density > 2.0 kg/dm3 1 Via dell'Industria 12 42025 Cavriago...

 Open the catalog to page 4
Technical datasheetPFG05-5

Extends the range of use of the indicator down to a minimum temperature of -40 ° C Intelligent automatic operation: when the temperature exceeds + 20 ° C it stops heating (heating OFF), it is reactivated when the temperature falls again below + 20 ° C (heating ON) Adds a LED lamp on top. The lamp could be connected to NC contact (MIN level - empty), or NO contact (MAX level - full). Must define a single 24[V] power supply voltage: 48[V] 115[V] 230[V] NOTE Model with lamp can be installed only in Atex zone 22 Marking: Ex II 3 D Ex tc IIIB T85°C Dc VOLTAGE CONTROL POWER SUPPLY SPRING TERMINAL BLOCK...

 Open the catalog to page 5