1. Catalogs
  2. CAMLogic Srl
  3. Technical datasheetPFG05

Technical datasheetPFG05

Technical datasheetPFG05

Technical datasheetPFG05

Product catalog summary
Overview: The document provides technical specifications and options for the PFG05 and PFG05/F models, which are industrial devices used for monitoring and control purposes. It includes details on power supply, signal capabilities, environmental conditions, and compliance with various directives.
Specifications:
  • Model: PFG05 and PFG05/F
  • Weight: PFG05 - 1.8 kg, PFG05/F - 2.3 kg
  • Power Supply: Bivoltage 115/230V (50-60Hz) - 4W, Bivoltage 24/48V (50-60Hz) - 4W, DC 24V ±15% - 4W
  • Signal: SPDT / max. 10A-250VAC
  • IP Grade: IP65
  • Housing: Aluminium (powder coated)
  • Connection: G2" 1/2 - Aluminium for PFG05, Flange - Aluminium for PFG05/F
  • Ambient Temperature: -20 to +70°C, -40 to +70°C
  • Process Temperature: -20 to +70°C, -40 to +70°C
  • Pressure Range: +0.8 to +1.1 bar
Compliance and Marking:
  • Directives: 2011/65/EU (RoHS), 2014/30/EU (EMC), 2014/34/EU (ATEX), 2014/35/EU (LVD)
  • ATEX Marking: Ex II 1/2 D Ex ta/tb IIIC T85°C IP65 Da/Db, Ex II 3 D Ex tc IIIB T85°C Dc (Lamp version)
  • IECEx Marking: Ex ta/tb IIIC T85°C Da/Db
Options:
  • Low Temperature Version: Extends use down to -40°C with automatic heating control.
  • Double Dry Contact: Adds a second signal contact SPDT.
  • Voltage Control: Provides an alarm for power supply failure.
  • Rotation Control: Indicates shaft rotation with a pulse signal.
  • Signal Lamp: Adds a LED lamp for level indication.
  • 4rpm Gearmotor: Increases paddle speed to reduce detection delay.
  • Condensation Filter: Prevents condensation without altering IP grade or Ex marking.
  • Terminal Blocks: Available in spring or screw terminal designs.
Materials and Extensions:
  • Materials: Various densities of AISI 304 stainless steel and PA 6 plastic.
  • Extensions: Available in lengths from 300mm to 12m, with options for galvanized or stainless steel.
See more

Catalog excerpts

Technical datasheetPFG05-1

VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY Terminals : male FASTON (.250 series / 6,3x0,8 mm) Housing Aluminium (powder coated) Ambient temperature Process temperature LOW TEMPERATURE versions only (PFG.../B) LOW TEMPERATURE versions only (PFG.../B) Pressure range +0,8 ... +1,1 bar 2011/65/EU (RoHS) ATEX Marking 2014/30/EU (EMC) 2014/34/EU (ATEX) 2014/35/EU (LVD) Ex II 1/2 D Ex ta/tb IIIC T85°C IP65 Da/Db Ex II 3 D Ex tc IIIB T85°C Dc (Lamp version) Via dell'Industria 12 42025 Cavriago (RE) - ITALY www.camlogic.it UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN [mm] DRAWING FROM CAD SYSTEM - REFER TO 3D MODEL FOR MISSING DIMENSION - NO MANUAL MODIFICATION ALLOWED IECEx Marking Ex ta/tb IIIC T85°C

 Open the catalog to page 1
Technical datasheetPFG05-2

VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY ROTATION CONTROL VOLTAGE CONTROL POWER SUPPLY 2x G 1/2 (BSPP) VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY Terminals : male FASTON (.250 series / 6,3x0,8 mm) Ambient temperature Process temperature Housing Aluminium (powder coated) Connection Flange - Aluminium -40 < Ta < +70 [°C] -20 < Tp < +70 [°C] LOW TEMPERATURE versions only (PFG.../B) LOW TEMPERATURE versions only (PFG.../B) Pressure range +0,8 ... +1,1 bar 2011/65/EU (RoHS) ATEX Marking 2014/30/EU (EMC) 2014/34/EU (ATEX) 2014/35/EU (LVD) Ex II 1/2 D Ex ta/tb IIIC T85°C IP65 Da/Db Ex II 3 D...

 Open the catalog to page 2
Technical datasheetPFG05-3

PSPX : stainless steel 1000 1200 Ø32: galvanized steel Ø30: stainless steel Extension with external protection PCPX : stainless steel PRSX : stainless steel Ø32: galvanized steel Ø30: stainless steel external protection PRP : galvanized steel PRPX : stainless steel Flexible extension PF : galvanized steel Via dell'Industria 12 42025 Cavriago (RE) - ITALY www.camlogic.it UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN [mm] DRAWING FROM CAD SYSTEM - REFER TO 3D MODEL FOR MISSING DIMENSION - NO MANUAL MODIFICATION ALLOWED NOTE : lenghts may slightly differ from the tables according to the type of connection,...

 Open the catalog to page 3
Technical datasheetPFG05-4

AC6 INOX AISI 304 density > 0.1 kg/dm3 AC10 INOX AISI 304 density > 0.6 kg/dm3 AC9 INOX AISI 304 density > 0.2 kg/dm3 AC7 INOX AISI 304 density > 0.3 kg/dm3 AC5L INOX AISI 304 density > 0.2 kg/dm3 AC4 INOX AISI 304 density > 0.5 kg/dm3 AC3 INOX AISI 304 density > 0.3 kg/dm3 AC12 INOX AISI 304 density > 0.4 kg/dm3 AC14 INOX AISI 304 density > 0.4 kg/dm3 AC16 INOX AISI 304 density > 0.3 kg/dm3 AC18 INOX AISI 304 density > 0.7 kg/dm3 AC17 INOX AISI 304 density > 0.4 kg/dm3 AC11 INOX AISI 304 density > 0.1 kg/dm3 AC8 galvanized steel (wires) density > 2.0 kg/dm3 1 Via dell'Industria 12 42025 Cavriago...

 Open the catalog to page 4
Technical datasheetPFG05-5

Extends the range of use of the indicator down to a minimum temperature of -40 ° C Intelligent automatic operation: when the temperature exceeds + 20 ° C it stops heating (heating OFF), it is reactivated when the temperature falls again below + 20 ° C (heating ON) Adds a LED lamp on top. The lamp could be connected to NC contact (MIN level - empty), or NO contact (MAX level - full). Must define a single 24[V] power supply voltage: 48[V] 115[V] 230[V] NOTE Model with lamp can be installed only in Atex zone 22 Marking: Ex II 3 D Ex tc IIIB T85°C Dc VOLTAGE CONTROL POWER SUPPLY SPRING TERMINAL BLOCK...

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.