1. Catalogs
  2. CAMLogic Srl
  3. Technical datasheet PFG05AT

Technical datasheet PFG05AT
1 /5Pages

Technical datasheet PFG05AT

Technical datasheet PFG05AT
1 /5Pages

Catalog excerpts

Technical datasheet PFG05AT-1

VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY Terminals : male FASTON (.250 series / 6,3x0,8 mm) AC4INOX density > 0,5kg/dm3 IP grade IP65 Housing Aluminium (powder coated) Connection G2" 1/2 - AISI304 Process temperature Pressure range LOW TEMPERATURE versions only (PFG.../B) LOW TEMPERATURE versions only (PFG.../B) Ambient temperature ATEX Marking 2014/30/EU (EMC) 2014/34/EU (ATEX) 2014/35/EU (LVD) Ex II 1/2 D Ex ta/tb IIIC T85°C IP65 Da/Db Ex II 3 D Ex tc IIIB T85°C Dc (Lamp version) IECEx Marking Ex ta/tb IIIC T85°C Da/Db Via dell'Industria 12 42025 Cavriago (RE) - ITALY www.camlogic.it UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN [mm] DRAWING FROM CAD SYSTEM - REFER TO 3D MODEL FOR MISSING DIMENSION - NO MANUAL MODIFICATION ALLOWED

 Open the catalog to page 1
Technical datasheet PFG05AT-2

VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY ROTATION CONTROL POWER SUPPLY VOLTAGE CONTROL VOLTAGE CONTROL ROTATION CONTROL POWER SUPPLY Terminals : male FASTON (.250 series / 6,3x0,8 mm) AC3INOX density > 0,3 kg/dm3 Power supply - Bivoltage 24/48[V] (50...60Hz) - 4[W] - DC 24[V] ±15% - 4[W] Signal SPDT / max. 10[A]-250VAC IP grade IP65 Housing Aluminium (powder coated) Connection Flange - AISI304 Process temperature Pressure range LOW TEMPERATURE versions only (PFG.../B) LOW TEMPERATURE versions only (PFG.../B) Ambient temperature ATEX Marking 2014/30/EU (EMC) 2014/34/EU (ATEX) 2014/35/EU (LVD)...

 Open the catalog to page 2
Technical datasheet PFG05AT-3

Flexible extension PF : galvanized steel 6 Extension with external protection PA : stainless steel 1400 1450 1500 other lengths available on request, Via dell'Industria 12 42025 Cavriago (RE) - ITALY www.camlogic.it UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN [mm] DRAWING FROM CAD SYSTEM - REFER TO 3D MODEL FOR MISSING DIMENSION - NO MANUAL MODIFICATION ALLOWED NOTE : lenghts may slightly differ from the tables according to the type of connection, model type and paddle chosen

 Open the catalog to page 3
Technical datasheet PFG05AT-4

AC4 INOX AISI 304 density > 0.5 kg/dm3 AC5L INOX AISI 304 density > 0.2 kg/dm3 AC6 INOX AISI 304 density > 0.1 kg/dm3 AC7 INOX AISI 304 density > 0.3 kg/dm3 AC3 INOX AISI 304 density > 0.3 kg/dm3 AC1 INOX AISI 304 density > 1.0 kg/dm3 AC9 INOX AISI 304 density > 0.2 kg/dm3 AC12 INOX AISI 304 density > 0.4 kg/dm3 AC11 INOX AISI 304 density > 0.1 kg/dm3 AC14 INOX AISI 304 density > 0.4 kg/dm3 AC10 INOX AISI 304 density > 0.6 kg/dm3 AC8 galvanized steel (wires) density > 2.0 kg/dm3 AC16 INOX AISI 304 density > 0.3 kg/dm3 AC18 INOX AISI 304 density > 0.7 kg/dm3 AC17 INOX AISI 304 density > 0.4 kg/dm3...

 Open the catalog to page 4
Technical datasheet PFG05AT-5

Extends the range of use of the indicator down to a minimum temperature of -40 ° C Intelligent automatic operation: when the temperature exceeds + 20 ° C it stops heating (heating OFF), it is reactivated when the temperature falls again below + 20 ° C (heating ON) SIGNAL LAMP (PFG05.../L) Adds a LED lamp on top. The lamp could be connected to NC contact (MIN level - empty), or NO contact (MAX level - full). Must define a single 24[V] power supply voltage: 48[V] 115[V] 230[V] POWER SUPPLY Must define a single 24[V] power supply voltage: 48[V] 115[V] 230[V] DOUBLE DRY CONTACT Adds a second signal...

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.