video corpo

SINEAX F534
4Pages

{{requestButtons}}

Catalog excerpts

SINEAX F534 - 1

Application The transducer SINEAX F534 (Fig. 1) is intended for frequency measurement. The instrument change the measured value into a proportional load independent DC current or DC voltage. The transducer fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 9001. Features / Benefits • Measuring input: Sine, rectangular or distorted wave forms of nominal input voltage with dominant fundamental waves Measured variable Overload capacity: • Measuring output: Unipolar, bipolar or live zero output variables • Measuring principle: Digital period measurement • AC/DC power supply / Universal • Standard as marine version per Lloyd's Register of Shipping Technical data General Measured quantity: Measuring principle: Measuring input -0 Measuring ranges: Frequency Digital period measurement Input quantity UN 1 But max. 264 V with power supply from voltage measuring input Wave form: Any; fundamental wave only taken into account Min. span: Nominal input voltage U ■ Selectable between fu = 10 Hz and fo =1500 Hz fu / (fo - fu) < 50 10 ... 230 V or 230 ... 690 V (max. 230 V with power supply from voltage measuring input) Measuring output 0*-Load-independent DC current: Burden voltage: Load-independent DC voltage: Load capacity: Camille Bauer

Open the catalog to page 1
SINEAX F534 - 2

Voltage limit under Rext = oo: < 25 Current limit under voltage output: Approx. 30 mA Residual ripple in output current: < 0.5% p.p. Power supply from voltage measuring input: Nominal value of response time: 4 periods of the measuring frequency Other ranges: 2, 8 or 16 periods of the measuring Power consumption: Installation data Mechanical design: 24 ... 60 V AC or 85 ... 230 V AC, Note: 40 Hz < f < 400 Hz Connect to the low tension to terminals 12 and 13 24 V AC or 24 ... 60 V DC 3 VA Accuracy (acc. to EN 60 688) Reference value: Basic accuracy: Reference conditions Ambient...

Open the catalog to page 2
SINEAX F534 - 3

SINEAX F534 Transducer for Measuring Frequency Output characteristic A Legend: E = Input EA = Input start value EE = Input end value A = Output AA = Output start value AE = Output end value Table 2: Specification and ordering information *Blocking code Description SINEAX F534 Order code 534 - xxxx xx Features, Selection 1. Mechanical design Housing P13/70 for rail mounting 2. Nominal input voltage UN: 10 … 230 V UN: > 230 … 690 V Not possible with power supply from measuring input 3 phase system: Input voltage = phase to phase voltage 3. Measuring range 45 … 50 … 55 Hz 47 … 49 … 51 Hz 47.5 …...

Open the catalog to page 3
SINEAX F534 - 4

* Lines with letter(s) under “no-go" cannot be combined with preceding lines having the same letter under “Blocking code". Electrical connections input O = Measuring output = Power supply Dimensional drawing A CAMILLE BAUER Rely on us. info@camillebauer.com www.camillebauer.com Standard accessories 1 Operating Instructions in three languages: German, French, English Subject to change without notice • Edition 03.12 • Data sheet F534 Le

Open the catalog to page 4

All Camille Bauer Metrawatt AG catalogs and technical brochures

  1. Camille Bauer

    12 Pages

  2. A2000

    10 Pages

  3. APLUS-LED

    89 Pages

  4. SIRAX BT5100

    32 Pages

  5. SINEAX CAM

    12 Pages

  6. SINEAX V604s

    12 Pages

  7. SMARTCOLLECT

    8 Pages

  8. KINAX WT720

    4 Pages

  9. KINAX N702

    6 Pages

  10. KINAX HW730

    4 Pages

  11. SINEAX TV829

    2 Pages

  12. SINEAX DM5

    4 Pages

  13. SINEAX VS30

    4 Pages

  14. KINAX 3W2

    4 Pages

Archived catalogs