video corpo

SINEAX DM5
4Pages

{{requestButtons}}

Catalog excerpts

SINEAX DM5 - 1

• System state monitoring: class 0.2 • All-purpose: V/I, P/Q/S, f, PF etc. • Remote communication via Modbus • DM5S: Energy metering class 0.5S • DM5F: Response time 15…25ms • Configuration even without power supply SINEAX DM5S/DM5F Programmable premium class heavy curren

Open the catalog to page 1
SINEAX DM5 - 2

DM5S/DM5F - The next transducer generation SINEAX DM5S and SINEAX DM5F are free-programmable universal measurement devices for heavy-current systems: Classical high-accuracy transducer, suited for monitoring tasks and retrofit applications in energy distribution and industry. The measurement is done uninterrupted in all four quadrants and can be adapted optimally to the system to be monitored. Both the average time of the measurement and the expected maximum signal level can be configured. The devices can be adapted fast and easily to the measurement task by means of the CB-Manager software –...

Open the catalog to page 2
SINEAX DM5 - 3

DM5S: Energy consumption monitoring in class 0.5S The DM5S supports up to 32 energy meters. To each of these meters a base measurement quantity and a tariff can be assigned. The present tariff is set via Modbus. For application with short measurement times, e.g. energy consumption for a single working day or production lot, the resolution can be adapted. Thanks to uninterrupted measurement and automatic range detection a high accuracy is achieved. • Up to 32 meters • Up to 16 tariffs (Control via Modbus) • Free selectable base quantity (P, Q, S, I) • High accuracy 0.5S • Uninterrupted...

Open the catalog to page 3
SINEAX DM5 - 4

Technical data via screw terminals 6mm2 adjustable 1...5 A 7.5 A (sinusoidal) ≤ I2 x 0.01 Ω per phase 10 A continuous 100 A, 10 x 1 s, interval 100 s Nominal voltage: Maximum: Consumption: Impedance: Overload capability: 57.7…400 VLN, 100...693 VLL 480 VLN, 832 VLL (sinusoidal) ≤ U2 / 1.54 MΩ per phase 1.54 MΩ per phase 480 VLN, 832 VLL continuous 600 VLN, 1040 VLL, 10 x 10 s, interval 10 s 800 VLN, 1386 VLL, 10 x 1 s, interval 10 s Nominal frequency: Measurement TRMS: Single phase Split phase (2 phase system) 3-wire, balanced load 3-wire, balanced load, phase shift (DM5S only) 3-wire,...

Open the catalog to page 4

All Camille Bauer Metrawatt AG catalogs and technical brochures

  1. Camille Bauer

    12 Pages

  2. A2000

    10 Pages

  3. APLUS-LED

    89 Pages

  4. SINEAX F534

    4 Pages

  5. SIRAX BT5100

    32 Pages

  6. SINEAX CAM

    12 Pages

  7. SINEAX V604s

    12 Pages

  8. SMARTCOLLECT

    8 Pages

  9. KINAX WT720

    4 Pages

  10. KINAX N702

    6 Pages

  11. KINAX HW730

    4 Pages

  12. SINEAX TV829

    2 Pages

  13. SINEAX VS30

    4 Pages

  14. KINAX 3W2

    4 Pages

Archived catalogs