The document provides an overview of the LINAX PQ3000 and PQ5000 devices, which are designed for continuous monitoring of power quality and energy consumption. These devices aim to identify and address power quality issues proactively to prevent significant damage.
Power Quality Monitoring
Power quality monitoring has shifted from a reactive to a proactive approach to prevent device failures and process interruptions. The LINAX PQ3000/PQ5000 devices are Class A certified according to IEC 61000-4-30 Ed.3, ensuring reliable data for regulatory compliance and internal quality control. They support compliance reports for the EN 50160 voltage quality standard.
Features
  • Intuitive: User-friendly interface with language-specific menus and quick data access.
  • Multifunctional: Suitable for all network configurations, with customizable measured variables and alarm conditions.
  • Flexible: Modular design with various functionalities and interfaces.
  • Scalable: High-resolution display for clear data presentation.
Avoiding Power Quality Problems
Continuous monitoring allows for the recognition of potential disruptions, enabling preventive measures. Data is stored in the PQDIF format, compatible with analysis programs like SMARTCOLLECT PM20 and PQView.
Power Quality Evaluation
  • Statistical Evaluation: Monitors supply voltage parameters and compares them to standards like EN 50160.
  • Malfunction Recording: Records disturbances such as voltage dips and swells, aiding in identifying causes and solutions.
Monitored Voltage Phenomena
The document lists various voltage phenomena, their causes, and potential problems, such as frequency instability, voltage dips, and harmonics, which can lead to equipment disruption and data loss.
Measured Values
The devices measure various parameters, including instantaneous values, reactive power, harmonics, imbalance, and energy balance, providing comprehensive data for analysis and energy management.
Monitoring and Alarming
The devices support on-site data analysis and immediate action initiation, with features like limit values, monitoring functions, and alarm systems.
Data Recording
Options include periodic data recording for load profiles and event recording for alarms and system changes. Data can be exported for further analysis.
Operation and Analysis
Local and web-based interfaces provide access to data and device configuration. The SMARTCOLLECT PM20 software facilitates detailed analysis and compliance reporting.
Technical Data
The document provides detailed technical specifications, including input ranges, power supply variants, connection types, and interface options, ensuring compatibility with various systems.
Protocols and Communication
The document outlines the use of Modbus/TCP, HTTP, and NTP for time synchronization. Modbus/RTU is standard for PQ5000 and optional for PQ3000. The physical layer uses RS-485 with a maximum distance of 1200 meters and supports baud rates from 9.6 to 115.2 kBaud, accommodating up to 32 participants.
Time Reference
The device features an internal clock with an accuracy of ±2 minutes per month within 15 to 30°C, synchronized via an NTP server, and a power reserve exceeding 10 years.
Environmental Conditions
Operating temperatures range from -10 to +55°C without UPS and 0 to +35°C with UPS. Storage temperatures range from -25 to +70°C. The device is suitable for use in buildings at altitudes up to 2000 meters and in environments with relative humidity below 95% without condensation.
Mechanical Properties
The housing is made of polycarbonate (Makrolon), classified as V-0 for flammability according to UL94, and is self-extinguishing, non-dripping, and halogen-free. The weight is 800g for PQ3000 and 600g for PQ5000.
Safety and Protection
Current inputs are galvanically isolated. The device has a protection class II, pollution degree 2, and protection ratings of IP54 (front), IP30 (housing), and IP20 (terminals). It falls under measurement category CATIII.
Order Codes and Extensions
Detailed order codes for PQ3000 and PQ5000 are provided, specifying options for power supply, bus connection, and extensions such as relays, analog outputs, digital inputs, and uninterruptible power supply.
SMARTCOLLECT Software
This data management software facilitates easy data acquisition and storage in an MS SQL database. It supports data communication via Modbus RTU/TCP, ECL, and SmartControl-Direct, and is compatible with devices from various manufacturers. The software is modular, allowing for extensions and includes components like SMARTCOLLECT CLIENT, DATABASE, and SERVER for data visualization, export, and management.
See more

Catalog excerpts

LINAX PQ-series-1

AVOIDING POWER QUALITY PROBLEMS COMBINED POWER QUALITY AND ENERGY CONSUMPTION MONITORING LINAX PQ-SERIES LINAX PQ3000 ▪ LINAX PQ5000

 Open the catalog to page 1
LINAX PQ-series-2

POWER QUALITY POWER SYSTEM MONITORING Comprehensive instrument for power quality monitoring in electric mains Traditionally, power quality monitoring is only conducted as a reaction to trouble such as device failure, plant malfunctions, process interruptions or communication breakdowns. However, all these problems cost money and nobody wants to experience the same thing again just to be able to create a corresponding record for analysis. Therefore, the biggest advantage of continuous power quality monitoring is that users put themselves in a position to proactively build up their knowledge thus...

 Open the catalog to page 2
LINAX PQ-series-3

CLEAR High resolution, colour TFT display for the pin-sharp indication of measured data Consistently visible status information (alarms, password protection, data recording, time/date and much more) Clear Design INTUITIVE Language-specific plain text menu navigation Topical arrangement of measured value information for quick data access Service area for maintenance and commissioning MULTIFUNCTIONAL Certified power quality monitoring according to IEC 61000-4-30 Ed. 3, class A Acquisition of energy consumption: Meters and load profiles Plant condition monitoring FLEXIBLE Applicable in all network...

 Open the catalog to page 3
LINAX PQ-series-4

POWER SYSTEM MONITORING POWER QUALITY AVOIDING POWER QUALITY PROBLEMS - THROUGH CONTINUOUS MONITORING Disruptions of the energy supply may result in production or equipment outages. Often people do not react until great financial damage has been caused. Yet, many of these incidents could be avoided if the signs were recognised in the continuous monitoring of the situation. Any form of power quality monitoring provides both a statistical evaluation allowing the comparison with standards (e.g. EN 50160) or supply contracts as well as records of events in the grid (e.g. voltage dips). This facilitates...

 Open the catalog to page 4
LINAX PQ-series-5

POWER SYSTEM MONITORING POWER QUALITY MONITORED VOLTAGE PHENOMENON Mains frequency Magnitude of supply voltage Loss of power generators Large load changes Changes in grid load POSSIBLE CONSEQUENTIAL PROBLEMS •• Instability of the mains power supply Disruption of equipment System shut-down •• Loss of data •• •• Flicker and rapid voltage changes (RVC) Supply voltage dips and swells Frequent load changes Start of engines Large load changes Short circuit, contact to earth •• Thunderstorm •• Power supply overload •• Feed-in of renewable energies such as wind or photovoltaic energy •• •• Voltage interruptions...

 Open the catalog to page 5
LINAX PQ-series-6

POWER QUALITY POWER SYSTEM MONITORING MEASURED VALUES APPLICATION MEASURED VALUE GROUP INSTANTANEOUS VALUES U, I, IMS, P, Q, S, PF, LF, QF ... Angle between voltage phasors Min/max of instantaneous values with time stamp EXTENDED REACTIVE POWER ANALYSIS Total reactive power, fundamental frequency, harmonics cos^, tan^ of fundamental frequency with min values in all quadrants HARMONICS ANALYSIS (ACCORDING TO IEC 61000-4-7) Total harmonics content THD U/I and TDD I Individual harmonics U/I up to 50th IMBALANCE ANALYSIS Symmetrical components (positive, negative, zero sequence system) Imbalance...

 Open the catalog to page 6
LINAX PQ-series-7

POWER QUALITY DATA RECORDING Apart from the automatic recording of power quality statistics, the high-performance data logger provides the following recording options: • PERIODIC DATA This feature allows to record the time course of measured variables. Averaged measurements or meter contents serve as base and are saved in regular intervals. Typical applications are the acquisition of load profiles (intervals of 10s to 1h) or the determination of the energy consumption from the difference of meter readings. For both categories pre-defined courses are available, based on the system power values, and...

 Open the catalog to page 7
LINAX PQ-series-8

POWER QUALITY POWER SYSTEM MONITORING OPERATION AND ANALYSIS OPERATION The local operation at the device itself and the access via web interface are structured identically. One can access the available measured data, parametrise the instrument or use the service functions via the language-specific, topically structured menu navigation. The status bar at the top right, uniformly shows the statuses of alarm monitoring, the password protection system, the data recording and the UPS as well as time and date. Apart from the details of the PQ statistics, all data are available via both the local GUI...

 Open the catalog to page 8
LINAX PQ-series-9

POWER QUALITY TECHNICAL DATA INPUTS NOMINAL CURRENT 1 ... 5 A (max. 7.5 A) Maximum 7.5 A Overload capacity 10 A permanent BASIC UNCERTAINTY ACCORDING IEC/EN 60688 NOMINAL VOLTAGE Maximum Overload capacity Nominal frequency THD U, I Active energy Reactive energy POWER SUPPLY VARIANTS Nominal voltage 100...230 V AC/DC (PQ5000) INTERFACES ETHERNET Connection Physics Mode Protocols Standard RJ45 socket Ethernet 100Base TX 10/100 MBit/s, full/half duplex, autonegotiation Modbus/TCP, http, NTP (time synchronisation) MODBUS/RTU Standard (PQ5000), optional (PQ3000) Baud rate 9.6 to 115.2...

 Open the catalog to page 9
LINAX PQ-series-10

POWER QUALITY POWER SYSTEM MONITORING

 Open the catalog to page 10
LINAX PQ-series-11

POWER QUALITY SMARTCOLLECT SMARTCOLLECT SERVER SMARTCOLLECT is a data management software which can acquire measured data in an easy manner and store the same in an open MS SQL database. This software offers basic functionalities for data analysis and for easy energy monitoring as well as the easy preparation and disposal of reports. Providing a mature graphic user interface, the SMARTCOLLECT software is clearly structured and easily operated. SMARTCOLLECT is modularly designed and permits supplementing modules or functions at any time. CUSTOMER BENEFITS • Easy data communication via Modbus RTU...

 Open the catalog to page 11
LINAX PQ-series-12

Subject to change without notice ▪ SM-1039-000-02-EN-08.17 Camille Bauer Metrawatt AG Aargauerstrasse 7 ▪ 5610 Wohlen ▪ Switzerland TEL +41 56 618 21 11 ▪ FAX +41 56 61

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.