Power System Monitoring Overview
Traditional power quality monitoring is reactive, addressing issues post-occurrence. Continuous monitoring with devices like LINAX PQ3000 and PQ5000 enables proactive management, enhancing system availability and preventing damage. These devices comply with IEC 61000-4-30 Ed.3 and support EN 50160 compliance reporting.
Key Features of LINAX PQ3000/PQ5000
  • Intuitive Operation: Certified monitoring with user-friendly menus and easy data access.
  • Multifunctional: Suitable for all network configurations, with customizable alarms and data recording.
  • Flexible Design: Combines functionality and interfaces, compatible with SMARTCOLLECT software.
  • Clear Display: High-resolution TFT display for clear data visualization.
Avoiding Power Quality Problems
Continuous monitoring helps prevent disruptions that lead to financial losses. LINAX devices store data in PQDIF format, facilitating analysis with software like SMARTCOLLECT PM20. They provide statistical evaluations and event recordings to identify and address power quality issues.
Monitored Voltage Phenomena and Consequences
  • Mains Frequency: Instability can cause equipment disruption and data loss.
  • Voltage Dips/Swells: Caused by load changes or short circuits, leading to operational interruptions.
  • Voltage Unbalance: Results from uneven phase loads, causing equipment overheating.
  • Voltage Harmonics: Non-linear loads reduce efficiency and increase energy losses.
Measured Values and Analysis
  • Instantaneous Values: Monitor system state and detect faults.
  • Reactive Power Analysis: Compensate reactive power and verify power factor.
  • Harmonics Analysis: Evaluate equipment thermal load and system perturbations.
  • Energy Balance Analysis: Manage energy consumption and efficiency.
Monitoring and Alarming
The device supports on-site data analysis and immediate action initiation. It includes limit values, monitoring functions, and alarms to protect equipment and monitor service intervals.
Data Recording
  • Periodic Data: Records load profiles and energy consumption trends.
  • Events: Logs alarms and system events for analysis.
  • PQ Events: Provides detailed event recordings for further analysis.
Operation and Analysis
Local and web-based interfaces provide access to data and device configuration. SMARTCOLLECT PM20 software allows detailed analysis and compliance reporting.
Technical Data
  • Inputs: Nominal current and voltage specifications, with overload capacities.
  • Power Supply: Various voltage options with low consumption.
  • I/O Interface: Optional analog outputs, relays, and digital inputs/outputs.
  • Fault Current Monitoring: For grounded systems with multiple measurement channels.
Specifications
Precision levels for electrical measurements: voltage and current at ±0.1%, power at ±0.2%, power factor at ±0.1°, frequency at ±0.01 Hz, imbalance at ±0.5%, harmonic and THD at ±0.5%. Active and reactive energy are classified as Class 0.5S according to IEC/EN standards.
Interfaces
Ethernet is standard with 100Base TX and RJ45 socket, supporting Modbus/TCP, HTTP, and NTP protocols. Modbus/RTU is standard for PQ5000 and optional for PQ3000, with RS-485 physics and a baud rate of 9.6 to 115.2 kBaud.
Time Reference
The internal clock has an accuracy of ±2 minutes/month between 15 to 30°C, with synchronization possible via NTP server or GPS.
Environmental Conditions
Operating temperature ranges from -10 to +55°C without UPS and 0 to +35°C with UPS. Storage temperature is from -25 to +70°C. The device is suitable for use in buildings only, with a relative humidity of <95% without condensation and an operating altitude of ≤2000 m.
Mechanical Properties
The housing is made of polycarbonate with a flammability class of V-0. The weight is 800g for PQ3000 and 600g for PQ5000.
Safety
Current inputs are galvanically isolated, with protection class II and pollution degree 2. The protection levels are IP54 for the front, IP30 for the housing, and IP20 for terminals.
Power System Monitoring
The document emphasizes the importance of avoiding power quality problems and provides details on panel cut-out and extensions for PQ3000 and PQ5000 devices.
Order Codes
Detailed order codes are provided for PQ3000 and PQ5000, specifying options for display, frequency range, power supply, bus connection, extensions, and test certificates.
SMARTCOLLECT Software
SMARTCOLLECT is a data management software for acquiring and storing measured data in an MS SQL database. It offers functionalities for data analysis, energy monitoring, and report preparation. The software is modular, allowing for extensions and supports easy data communication via Modbus RTU/TCP and other protocols.
Customer Benefits
The software supports devices from Camille Bauer and Gossen Metrawatt, is open to all manufacturers, and offers a modular cost/performance model.
Components
The software consists of SMARTCOLLECT Client for data visualization and export, SMARTCOLLECT Database for data storage, and SMARTCOLLECT Server for data collection and configuration.
See more

Catalog excerpts

Camille Bauer-1

AVOIDING POWER QUALITY PROBLEMS COMBINED POWER QUALITY AND ENERGY CONSUMPTION MONITORING LINAX PQ-SERIES LINAX PQ3000 ▪ LINAX PQ5000

 Open the catalog to page 1
Camille Bauer-2

POWER QUALITY POWER SYSTEM MONITORING Comprehensive instrument for power quality monitoring in electric mains Traditionally, power quality monitoring is only conducted as a reaction to trouble such as device failure, plant malfunctions, process interruptions or communication breakdowns. However, all these problems cost money and nobody wants to experience the same thing again just to be able to create a corresponding record for analysis. Therefore, the biggest advantage of continuous power quality monitoring is that users put themselves in a position to proactively build up their knowledge thus...

 Open the catalog to page 2
Camille Bauer-3

CLEAR High resolution, colour TFT display for the pin-sharp indication of measured data Consistently visible status information (alarms, password protection, data recording, time/date and much more) Clear Design INTUITIVE Language-specific plain text menu navigation Topical arrangement of measured value information for quick data access Service area for maintenance and commissioning MULTIFUNCTIONAL Certified power quality monitoring according to IEC 61000-4-30 Ed. 3, class A Acquisition of energy consumption: Meters and load profiles Plant condition monitoring FLEXIBLE Applicable in all network...

 Open the catalog to page 3
Camille Bauer-4

POWER SYSTEM MONITORING POWER QUALITY AVOIDING POWER QUALITY PROBLEMS - THROUGH CONTINUOUS MONITORING Disruptions of the energy supply may result in production or equipment outages. Often people do not react until great financial damage has been caused. Yet, many of these incidents could be avoided if the signs were recognised in the continuous monitoring of the situation. Any form of power quality monitoring provides both a statistical evaluation allowing the comparison with standards (e.g. EN 50160) or supply contracts as well as records of events in the grid (e.g. voltage dips). This facilitates...

 Open the catalog to page 4
Camille Bauer-5

POWER SYSTEM MONITORING POWER QUALITY MONITORED VOLTAGE PHENOMENON Mains frequency POSSIBLE CONSEQUENTIAL PROBLEMS Magnitude of supply voltage Loss of power generators Large load changes Changes in grid load Instability of the mains power supply Disruption of equipment System shut-down •• Loss of data •• Flicker and rapid voltage changes (RVC) Supply voltage dips and swells Frequent load changes Start of engines Large load changes Short circuit, contact to earth •• Thunderstorm •• Power supply overload •• Feed-in of renewable energies such as wind or photovoltaic energy Short circuit Blown fuses...

 Open the catalog to page 5
Camille Bauer-6

POWER QUALITY POWER SYSTEM MONITORING MEASURED VALUES APPLICATION MEASURED VALUE GROUP INSTANTANEOUS VALUES U, I, IMS, P, Q, S, PF, LF, QF ... Angle between voltage phasors Min/max of instantaneous values with time stamp EXTENDED REACTIVE POWER ANALYSIS Total reactive power, fundamental frequency, harmonics cos^, tan^ of fundamental frequency with min values in all quadrants HARMONICS ANALYSIS (ACCORDING TO IEC 61000-4-7) Total harmonics content THD U/I and TDD I Individual harmonics U/I up to 50th IMBALANCE ANALYSIS Symmetrical components (positive, negative, zero sequence system) Imbalance...

 Open the catalog to page 6
Camille Bauer-7

POWER SYSTEM MONITORING POWER QUALITY DATA RECORDING Apart from the automatic recording of power quality statistics, the high-performance data logger provides the following recording options: PERIODIC DATA This feature allows to record the time course of measured variables. Averaged measurements or meter contents serve as base and are saved in regular intervals. Typical applications are the acquisition of load profiles (intervals of 10s to 1h) or the determination of the energy consumption from the difference of meter readings. For both categories pre-defined courses are available, based on the...

 Open the catalog to page 7
Camille Bauer-8

POWER QUALITY POWER SYSTEM MONITORING OPERATION AND ANALYSIS OPERATION The local operation at the device itself and the access via web interface are structured identically. One can access the available measured data, parametrise the instrument or use the service functions via the language-specific, topically structured menu navigation. The status bar at the top right, uniformly shows the statuses of alarm monitoring, the password protection system, the data recording and the UPS as well as time and date. Apart from the details of the PQ statistics, all data are available via both the local GUI...

 Open the catalog to page 8
Camille Bauer-9

POWER QUALITY TECHNICAL DATA INPUTS NOMINAL CURRENT 1 ... 5 A (max. 7.5 A) Maximum 7.5 A Overload capacity 10 A permanent Measurement range 2 (2mA) RCM with connection monitoring • Measuring transformer Residual current transformer 500/1 up to 1000/1 A • Alarm limit 30 mA up to 1 A NOMINAL VOLTAGE Maximum Overload capacity Nominal frequency BASIC UNCERTAINTY ACCORDING IEC/EN 60688 POWER SUPPLY VARIANTS Nominal voltage 100...230 V AC/DC (PQ5000) THD U, I Active energy Reactive energy INTERFACES ETHERNET Physics Mode Protocols Standard Ethernet 100Base TX; RJ45 socket 10/100 MBit/s,...

 Open the catalog to page 9
Camille Bauer-10

POWER QUALITY POWER SYSTEM MONITORING Transformers for fault current detection see accessory current transformers EXTENSIONS PQ3000 Maximum one extension with analog outputs may be provided per device.

 Open the catalog to page 10
Camille Bauer-11

POWER QUALITY SMARTCOLLECT SMARTCOLLECT SERVER SMARTCOLLECT is a data management software which can acquire measured data in an easy manner and store the same in an open MS SQL database. This software offers basic functionalities for data analysis and for easy energy monitoring as well as the easy preparation and disposal of reports. Providing a mature graphic user interface, the SMARTCOLLECT software is clearly structured and easily operated. SMARTCOLLECT is modularly designed and permits supplementing modules or functions at any time. CUSTOMER BENEFITS • Easy data communication via Modbus RTU...

 Open the catalog to page 11
Camille Bauer-12

Subject to change without notice ▪ SM-1039-000-03-EN-04.18 Camille Bauer Metrawatt AG Aargauerstrasse 7 ▪ 5610 Wohlen ▪ Switzerland TEL +41 56 618 21 11 ▪ FAX +41 56 61

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.