SYNRAD PS-401 DC Power Supply
5Pages

{{requestButtons}}

Catalog excerpts

SYNRAD PS-401 DC Power Supply - 1

SYNRAD PS-401 DC Power Supply (Power-One FXC7000-48-S) PS-401 Front View Remove and rotate access panel 180° for input voltage selection Nominal 380–480 VAC; 3Ø Min/Max Range 342–528 VAC; 3Ø Nominal 200–240 VAC; 3Ø Min/Max Range 180–264 VAC; 3Ø PS-401 Rear View +48 VDC Output DC Output Connections: * Fasten DC Positive (red cable) to Positive (+) +48 VDC Output terminal. * Fasten DC Return (black cable) to Negative (–) –DC Output terminal. AC AC Input Connections: (180–264/342–528 3Ø VAC) * Attach AC safety ground (earth) to terminal labeled “PE”. * Connect Phase 1 to terminal labeled “L1”. * Connect Phase 2 to terminal labeled “L2”. * Connect Phase 3 to terminal labeled “L3”. Detail of 26-Pin HD Signal Connector 9 18 26 Output Interlock (Pin 5) and Output Inhibit (Pin 25) - connect to Logic Ground (Pin 9, 14, 15, or 23) to Enable DC supply. Remote Sense V+ (Pin 19) - reference to +48 VDC Output at laser. Remote Sense V– (Pin 21 - reference to –DC Output at laser. * These connections are built-in to the i401’s DC Power Cable assembly 4600 Campus Place • Mukilteo WA 98275 • tel 425.349.3500 • fax 4

Open the catalog to page 1
SYNRAD PS-401 DC Power Supply - 2

FXC7000 AC-DC Series Data Sheet power-one-— ^Changing the Shape of Power B\sirW«P«erm''l't"4 C€ FXC7000 Front anTtiear Views Description The FXC7000 Series of standalone or rack-mounted power systems provides true AC front-end capability to automatic test equipment, telecom, data communications, and other distributed power designs. The FXC systems may be paralleled up to 210 kW of output power and are intended for chassis-mounted installations with bolted connections. These power supplies provide excellent protection against input voltage transients. The FXC has its fan located at the front...

Open the catalog to page 2
SYNRAD PS-401 DC Power Supply - 3

^Changing the Shape of Power FXC7000 AC-DC Series Data Sheet Output Specifications Output Voltage An additional 1.0 Volt is provided to the output terminals to provide for Adjustment Range_load lead losses._ Output Power_Continuous duty rating._ Output Current_Continuous duty rating._ Efficiency_Full rated load (208Vac)._ Regulation Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: With Remote Sense not connected: Utilizing Droop Current Share: _Line, Under all specified operating conditions._ Ripple & Noise Measured at mating connector w/ 0.01pF + 10pF Tant....

Open the catalog to page 3
SYNRAD PS-401 DC Power Supply - 4

^Changing the Shape of Power FXC7000 AC-DC Series Data Sheet Safety, Regulatory, and EMI Specifications _CE marked for the Low Voltage Directive_ Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. _EN55022 / CISPR 22 Conducted._ ESD Susceptibility_Per EN61000-4-2, level 4._ Radiated Susceptibility_Per EN61000-4-3, level 3._ Input Transient Protection Per EN61000-4-5 Line-to-Line: _Line-to-Ground: Voltage Sag Immunity_Per SEMI F47-0200 FXC/FXP6000_ Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. _Non-Operating._...

Open the catalog to page 4
SYNRAD PS-401 DC Power Supply - 5

FXC7000 AC-DC Series Data Sheet MAINTAIN 25 SQ IN MIN FREE AREA (FRONT AND REAR) FOR AIR COOLING INSULATOR BLOCK <--AIRFLOW SIDE VIEW A FOR MOUNTING, USE M4 X 0.7 SCREWS, 8PL (MARKED A) ON SIDE OR BOTTOM WITH MAXIMUM PENETRATION 3.8mm. RECOMMENDED MOUNTING TORQUE 10.5 INCH LBS. (0.64N/M) FRONT VIEW MATING CONNECTOR: CONNECTOR SHELL... AMP PN 748365-1 CONTACTS... AMP PN 748333-2 INPUT VOLTAGE RANGE SELECT MODULE ROTATE 180 DEGREES FOR 240 VAC INPUT VOLTAGE DISPLAY CUTOUT

Open the catalog to page 5

All Cambridge Technology catalogs and technical brochures

  1. LXP Hybrid

    5 Pages

  2. ProSeries 2

    4 Pages

  3. CRS Series

    3 Pages

  4. Pen Motors

    3 Pages