Overview: The document provides detailed technical specifications and features of the ProSeries PS1 Scan Heads, designed for high-performance applications in material processing. These scan heads are known for their low noise, high marking speed, and thermal stability, making them suitable for precision-driven tasks.
Key Specifications:
  • Technology: Utilizes ProSeries Analog Technology with 62xx Low Drift Galvanometer and MicroMax Analog Servo Driver Technology, ensuring factory-tuned performance.
  • Sizes: Available in clear aperture sizes of 7mm, 10mm, and 14mm, supporting a broad range of lenses.
  • Communication: Offers both analog and digital XY2-100 communication protocols with standard power and communication pinouts.
  • Design: Features a standard mechanical 4-bolt interface and customizable lens grid correction files.
Applications: Ideal for OEM design integration or as replacements to enhance system performance in applications such as high accuracy marking, scribing, photovoltaic, coding, rapid manufacturing, trimming, engraving, and perforating.
Technical Specifications:
  • Aperture Sizes: 7mm, 10mm, 14mm with corresponding beam displacements of 9.3mm, 13.2mm, and 18.5mm.
  • Performance: Step response times range from 160 µs to 360 µs, with typical mark speeds between 2.5 m/s and 4.5 m/s.
  • Resolution: Consistent across models at 12 µrad.
  • Drift and Stability: Long-term offset and scale drifts are specified, with temperature-related drifts also detailed.
  • Power and Communication: Requires ±15 V DC to ±28 V, with digital and analog communication options.
  • Environmental: Operating temperature is 25º ± 10º C.
  • Mirror Coatings and Lenses: Various coatings and F-theta lenses are supported, including YAG, CO2, and DYAG.
Design and Dimensions: The document includes detailed dimensions and mechanical design specifications for each model, ensuring compatibility and ease of integration.
See more

Catalog excerpts

PS1-07: ProSeries1 7mm Scan Head-1

ProSeries PS1 Scan Heads For 7, 10 & 14mm Clear Apertures Key Specifications • ProSeries Analog Technology - 62xx Low Drift Galvanometer Technology - MicroMax Analog Servo Driver Technology - Factory Tuned n APPLICATIONS EXPER TISE • Family of Sizes - Clear Aperture Sizes of 7mm,10mm,14mm - Broad Range of Supported Lenses • Plug & Play - Analog or Digital XY2-100 Communication Protocol ProSeries Scan Heads Cambridge Scanning Solutions brings you a new family of high performance, low noise scan heads for the fastest scan rates and for low drift. The ProSeries PS1 Scan Heads offer high performance galvanometers and the latest analog servo technology with lower noise and better thermal stability than other systems and the highest marking speed performance in a compact rugged scan head design. These core components are offered with industry standard mechanical bolt patterns, industry standard power and communication pinouts as well as a range of popular apertures, mirror - Standard Power and Communication Pinouts - Standard Mechanical 4-Bolt Interface - Standard and Custom Lens Grid Correction Files coatings and lenses. These scan heads are ideal for easy OEM design integration or as drop in replacements to improve total system performance and are suited for applications such as high accuracy marking, scribing, photovoltaic, coding, rapid manufacturing, trimming, engraving, perforating and more. ProSeries PS1 Scan Heads give the highest marking rates, good accuracy, low dither and high stability beam steering for superior performance and quality for your most demanding precision driven material processing applications.

 Open the catalog to page 1
PS1-07: ProSeries1 7mm Scan Head-2

Technical Specifications and Dimensions: ProSeries Scan Heads Scan Heads Product Specific Specifications Aperture Size Beam Displacement Step Response (1% Full Scale) Resolution Long Term Offset Drift (24 hours) Long Term Scale Drift3 (24 hours) Nonlinearity (Max. % over ± 20º optical) Typical Scan Angle Gain Error Zero Offset Digital Communication Analog Communication Power Requirements Mirror Coatings F-theta Lenses Operating Temp Settling to within 1% of position Single stroke 1 mm characters with f-160 lens 3 Sigma from mean position All angles are in optical degrees PS1-07: 9.3 Beam Offset...

 Open the catalog to page 2

All Cambridge Technology catalogs and technical brochures

  1. Diode Pointer

    2  Pages

  2. LXP Hybrid

    5  Pages

  3. ProSeries 2

    4  Pages

  4. CRS Series

    3  Pages

  5. Pen Motors

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.