7100 Multigas Analyser The Rapidox 7100 Multigas Analyser is a high specification instrument designed for the analysis, control and monitoring of process gas in a wide range of industries. Up to six gases are simultaneously measured using a range of high precision gas sensors; each sensor is specifically designed and calibrated to avoid any cross-interference effects with the background process gas. Measurable gases include oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), moisture (H2O), hydrogen (H2), hydrogen sulphide (H2S), nitric oxide (NO), nitrogen dioxide (NO2), nitrous oxide (N2O), sulphur dioxide (SO2), chlorine (Cl2), methane (CH4), ethylene (C2H4) and many more. View the sensor matrix for more information. When configured for applications where the gases contain energy (e.g. Biogas, Syngas) the calorific value of the gas sample is determined using thermodynamic calculations and simultaneously logged and displayed onscreen. Data is downloadable via USB memory stick, and 4GB of internal data storage allowance allows for approximately one year of continuous monitoring. An optional pump enables two modes of operation. For samples that are taken from a gas source at atmospheric pressure or below, the pump is activated to draw a sample through the analyser. Alternatively, the pump can be deactivated when sampling from a source at a greater atmospheric pressure, allowing the gas to flow through the analyser. Gas flow is regulated manually via a rotary knob on the fascia and displayed electronically on the screen. Available in both a 19" rack mountable case or a benchtop version. Please contact Cambridge Sensotec for further information or to discuss your requirements. configurable customer requirements, the Rapidox 7100 range possesses a number of standard features to enhance functionality. Bespoke sensor combination 1 9" rack mountable enclosure mains voltage Password protection

Open the catalog to page 1
Rapidox 7100 Technical Datasheet - 2

Research & Development Accessories 1 Calibration Kit 2 Multiplex Sampling System 3 Gas Recovery Bag 4 Thermal Printer 5 Calibration Service 6 Gas Filters For detailed specs on individual sensor performance, please contact us. Cambridge Sensotec Limited. Unit 29 Stephenson Road, St Ives, Cambs, PE27 3WJ, United Kingdom Due to continuous product development necessary changes to specifications may be made without prior notice. Issue no: V2-2018

Open the catalog to page 2
Rapidox 7100 Technical Datasheet - 3

Sensor Type Zr = Zirconia Oxygen Sensor EC-E = Electrochemical Oxygen Sensor % EC-L = Electrochemical Oxygen Sensor ppm Note: Not all sensor combinations are possible due to interference and cross-sensitivity effects. Please contact Cambridge Sensotec for advice Rapidox 7100 Sensor Matrix CAP = Capacitance dewpoint Sensor

Open the catalog to page 3

All Cambridge Sensotec catalogs and technical brochures