Catalog excerpts
Index Application QTLD 1D QTLD 1ST FT QMLD 2D QTLD 2D QTLD 2ST FT QTLD 3D FT-RL QTLD 3 ST-RL
Open the catalog to page 2Impedance stator Soft start
Open the catalog to page 3Control panels QM Control panel for 1 single-phase submersible pump Control panel with ON-OFF switch and capacitor, for 1 submersible pump with single-phase motor without built-in capacitor. - Enclosure in thermoplastic material - ON-OFF switch with lamp - Capacitor - Terminal board - Cable glands Technical data - Mains single-phase 230V ±10% 50/60 Hz (other voltages on request). - Ambient temperature from -5 °C to +40 °C. - Protection IP 55. QM Control panel with circuit breaker for 1 single-phase submersible pump Control panel with ON-OFF switch, circuit breaker and capacitor, for 1...
Open the catalog to page 4Control panels M COMP Control panel for 1 single-phase submersible pump M COMP 4-16 M COMP 4-20 M COMP 5-20 M COMP 5-25 M COMP 6-20 M COMP 6-35 M COMP 7-25 M COMP 7-30 M COMP 8-25 M COMP 8-30 M COMP 10-35 M COMP 10-40 M COMP 12-35 M COMP 12-50 M COMP 12-60 M COMP 16-70 Control panel with ON-OFF switch and capacitor for 1 submersible pump with single-phase motor. Suitable for use with LVBT board for level control. Protection is provided by means of a main bi-polar switch with a phase. protected against overload by means of a thermal element. Technical data - Enclosure in thermoplastic...
Open the catalog to page 5Control panels QML 1 FT Control panel for 1 pump with single-phase motor, direct starting Control panel for 1 pump with single-phase motor, direct starting for pressure booster sets, with a patented working time-measuring system that stops the pump in case of lack of air cushion in the pressure vessel. Arranged for the capacitor internal connection (for pumps without builtin capacitor) and for the SRL 3 level control card application against dry running. Pump operation controlled by an electronic board type MP 1000 with microprocessor which allows three different modes of operation of the...
Open the catalog to page 6Control panels PFC-T Power Factor Control Control panel for 1 submersible pump with three-phase motor, PF control Control panel for controlling 1 submersible pump with three-phase motor. Electronic control of the operation and dry-running protection through the power factor (PF) control. The installation of level probes into the well is not required. It stops the pump in case of lack of air cushion in the pressure vessel (patented system) Displayed operating data and alarms, available in four languages. - Min – Max voltage range - Motor rated current - Power factor (PF) value for...
Open the catalog to page 7Control panels QTL 1 D FTE Control panel for 1 pump with three-phase motor, direct starting Electromechanical control panel for 1 pump with three-phase motor, direct starting. Operating signals by E 1000 led card. Dry-running protection with float switch. Construction with SRLE level control for probes connection against dryrunning on request . - Metal case. - Door lock master switch. - Power circuit fuses. - Fuses for auxiliary circuit. - Starting contactor. - Thermal relay - Transformer. - E 1000 led card. - Terminals for connection pump operating signal. - Terminals for float switch...
Open the catalog to page 8Control panels QTL 1 ST FTE Control panel for 1 pump with three-phase motor, Y/Δ starting Electromechanical control panel for 1 pump with three-phase motor, Y/Δ starting. Operating signals by E 1000 led board. Dry-running protection with float switch. Construction with SRLE level control for probes connection against dry-running on request . - Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - Starting contactors. - Thermal relay. - Y/Δ timer. - Transformer. - E 1000 led board. - Terminals for motor connection. - Terminals for connection of pump...
Open the catalog to page 9Control panels QTL 1 IS FTE Control panel for 1 pump with three-phase motor, with Stator Impedence starter Electromechanical control panel for 1 submersible pump with three-phase motor, with Stator Impedence starter. Operating signals on led board type E 1000. Application : submersible motors control with great cable length. Construction with SRLE level control for probes connection against dryrunning . - Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - Stator Impedence - By pass contactors - Transformer. - E 1000 led board. - RLE level control...
Open the catalog to page 10Control panels QML 2 D Control panel for 2 pumps with single-phase motor, direct starting Control panel for 2 pumps with single-phase motor, direct starting for pressure booster sets, with a patented working time-measuring system that stops the pump in case of lack of air cushion in the pressure vessel. Arranged for SRL 3 level control application for probes connection against dry-running. Pump operation cascade mode controlled by an electronic board type MP 2000 with microprocessor which allows three different operation modes: standard, emergency and timed. - Thermoplastic case.- Door lock...
Open the catalog to page 11Control panels QTL 2 ST FT Control panel for 2 pumps with three-phase motor, Y/Δ starting Control panel for 2 pumps with three-phase motor, Y/Δ starting, for pressure booster sets, with a patented working time-measuring system that stops the pump in case of lack of air cushion in the pressure vessel. Pump operation cascade mode controlled by an electronic board type MP 2000 with microprocessor which allows three different operation modes: standard, emergency and timed. - Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - Starting contactors. -...
Open the catalog to page 12Control panels QTL 3 FT Control panel for 3 pumps with three-phase motor, direct starting Control panel for 3 pumps with three-phase motor, direct starting, for pressure booster sets, with a patented working time-measuring system that stops the pump in case of lack of air cushion in the pressure vessel . Arranged for SRL 3 level control application for probes connection against dry-running. Pump operation cascade mode controlled by an electronic board type MP 3000 with microprocessor which allows three different operation modes: standard, emergency and timed. - Thermoplastic case. - Door...
Open the catalog to page 13All Calpeda catalogs and technical brochures
-
Close Coupled Centrifugal Pumps
16 Pages
-
NM, NMS 60 Hz
16 Pages
-
NM, NMD
12 Pages
-
PMAT
1 Pages
-
Catalot 50 hz
624 Pages
-
catalog 60 hz
463 Pages
-
MP 60Hz
5 Pages
-
MP 50Hz
4 Pages
-
GM 10
2 Pages
-
GQN
4 Pages
-
E-MXP
8 Pages
-
CS, CS-R. FK
12 Pages
-
NCE EI
4 Pages
-
NCE H
5 Pages
-
NCE H F
5 Pages
-
NCE G F
5 Pages
-
NCED G F
5 Pages
-
NCE EL
4 Pages
-
NCE GS F
4 Pages
-
NCE ES
4 Pages
-
NCE PS
4 Pages
-
NCS3
3 Pages
-
NC3
4 Pages
-
NCD3
3 Pages
-
NCD
8 Pages
-
IDROMAT
2 Pages
-
EASYMAT
4 Pages
-
VARIOMAT
2 Pages
-
BS
90 Pages
-
AUE, AUD, AUED
20 Pages
-
MXH
12 Pages
-
N, N4
26 Pages
-
NM, NMD
12 Pages
-
GENERAL CATALOGUE 60HZ
378 Pages
-
GENERAL CATALOGUE 50HZ
584 Pages