MXH
12Pages

{{requestButtons}}

Catalog excerpts

MXH - 1

Horizontal Multi-Stage Close Coupled Pumps in stainless steel Construction Horizontal multi-stage close coupled pumps in chrome-nickel stainless steel. Compact and robust construction, without protruding flange and with single-piece lantern bracket and base. Single-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible from any side (like the terminal box). Applications For water supply. For clean liquids, without abrasives, which are non-aggressive for stainless steel (with suitable seal materials, on request). Universal pump, for domestic use, for civil and industrial applications, for garden use and irrigation. Operating conditions Liquid temperature from - 15 °C to + 110 °C. Ambient temperature up to 40 °C. Maximum permissible pressure in the pump casing: 8 bar. Continuous duty. Motor 2-pole induction motor, 50 Hz (n ≈ 2800 rpm). MXH: three-phase 230/400 V ± 10% up to 3 kW; MXHM: single-phase 230 V ± 10%, with thermal protector. Capacitor inside the terminal box. Insulation class F. Protection IP 54. Motor suitable for operation with frequency converter from 1,8 kW. Classification scheme IE2 for three-phase motors from 0,75 kW. Constructed in accordance with: EN 60034-1; EN 60034-30. EN 60335-1, EN 60335-2-41. Materials Component Pump casing Stage casing Wear ring Impeller Casing cover Spacer sleeve Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Chrome-nickel steel 1.4301 EN 10088 (AISI 304) PTFE Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Pump shaft Plug Chrome-nickel steel 1.4305 EN 10088 (AISI 303) Chrome-nickel steel 1.4305 EN 10088 (AISI 303) Mechanical seal with seat according to ISO 3069 Ceramic alumina, carbon, EPDM (Other materials on request) Special features on request - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet). - Protection IP 55. - Special mechanical seal - Pump casing seal rings in FPM. - Higher or lower liquid or ambient temperatures. - Motor suitable for operation with frequency converter up to 1,5 kW.

Open the catalog to page 1
MXH - 2

Horizontal Multi-Stage Close Coupled Pumps in stainless steel MXHM 802/A MXHM 803 MXHM 804 MXHM 805 P1 Max. power input. P2 Rated motor power output. MXHM 402E MXHM 403/A MXHM 404/A MXHM 405 MXHM 406 MXHM 202E MXHM 203E MXHM 204/A MXHM 205/A MXHM 206 Test results with clean cold water, without gas content. Tolerances according to UNI EN ISO 9906:2012 + 0,5 m security margin on NPSH-value is necessary.

Open the catalog to page 2
MXH - 3

Horizontal Multi-Stage Close Coupled Pumps in stainless steel

Open the catalog to page 3
MXH - 4

Horizontal Multi-Stage Close Coupled Pumps in stainless steel Extra safety against running dry, with the suction port above pump axis. Reliable All hydraulic parts in contact with the pumped liquid are of stainless steel. For liquids from -15 °C to 110 °C. Robust Single-piece, thick barrel casing. Compact Single-piece lantern bracket and base. Without protruding flange. Greater protection against leakage, with the pump casing cover separated from the motor shield. Possibility of inspecting the seal through the side apertures between the two walls. Greater protection against water entering...

Open the catalog to page 4
MXH - 5

Horizontal Multi-Stage Close Coupled Pumps Construction Horizontal multi-stage close coupled pumps in chromenickel-molybdenum stainless steel AISI 316L. Compact and robust construction, without protruding flange and with single-piece lantern bracket and base. Single-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible from any side (like the terminal box). Applications For water supply. For clean liquids, without abrasives, which are non-aggressive for stainless steel (with suitable seal...

Open the catalog to page 5
MXH - 6

Horizontal Multi-Stage Close Coupled Pumps MXHL 402E MXHL 403/A MXHL 404/A MXHL 405/B MXHL 406 MXHLM 402E MXHLM 403/A MXHLM 404/A MXHLM 405 MXHLM 406 MXHLM 802/A MXHLM 803 MXHLM 804 MXHLM 805 P1 Max. power input. P2 Rated motor power output. MXHLM 202E MXHLM 203E MXHLM 204/A MXHLM 205/A MXHLM 206 Test results with clean cold water, without gas content. Tolerances according to UNI EN ISO 9906:2012 + 0,5 m security margin on NPSH-value is necessary.

Open the catalog to page 6
MXH - 7

Horizontal Multi-Stage Close Coupled Pumps

Open the catalog to page 7
MXH - 8

Horizontal Multi-Stage Close Coupled Pumps Extra safety against running dry, with the suction port above pump axis. Reliable All hydraulic parts in contact with the pumped liquid are of stainless steel. For liquids from -15 °C to 110 °C. Robust Single-piece, thick barrel casing. Compact Single-piece lantern bracket and base. Without protruding flange. Greater protection against leakage, with the pump casing cover separated from the motor shield. Possibility of inspecting the seal through the side apertures between the two walls. Greater protection against water entering the motor from...

Open the catalog to page 8
MXH - 9

Horizontal Multi-Stage Close Coupled Pumps Construction Horizontal multi-stage close coupled pumps in chrome-nickel stainless steel. Compact and robust construction,with compact lantern bracket and motor with feet. Single-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible from any side (like the terminal box). Applications For water supply. For clean liquids, without abrasives, which are non-aggressive for stainless steel (with suitable seal materials, on request). Universal pump, for...

Open the catalog to page 9
MXH - 10

Horizontal Multi-Stage Close Coupled Pumps P2 Rated motor power output. Test results with clean cold water, without gas content. Tolerances according to UNI EN ISO 9906:2012 + 0,5 m security margin on NPSH-value is necessary. Flanges* Flange* Flanged ports MXH-F MXH-V 2001 MXH-V 2002 MXH-V 2003 MXH-V 2004 MXH-V 2005 MXH-V 3201/A MXH-V 3202/A MXH-V 3203/A MXH-V 3204/A MXH-V 4801/A MXH-V 4802/A MXH-V 4803/A Victaulic ports MXH-V MXH-F 2001 MXH-F 2002 MXH-F 2003 MXH-F 2004 MXH-F 2005 MXH-F 3201/A MXH-F 3202/A MXH-F 3203/A MXH-F 3204/A MXH-F 4801/A MXH-F 4802/A MXH-F 4803/A

Open the catalog to page 10

All Calpeda catalogs and technical brochures

  1. NM, NMS 60 Hz

    16 Pages

  2. NM, NMD

    12 Pages

  3. PMAT

    1 Pages

  4. Catalot 50 hz

    624 Pages

  5. catalog 60 hz

    463 Pages

  6. MP 60Hz

    5 Pages

  7. MP 50Hz

    4 Pages

  8. GM 10

    2 Pages

  9. GQN

    4 Pages

  10. E-MXP

    8 Pages

  11. CS, CS-R. FK

    12 Pages

  12. NCE EI

    4 Pages

  13. NCE H

    5 Pages

  14. NCE H F

    5 Pages

  15. NCE G F

    5 Pages

  16. NCED G F

    5 Pages

  17. NCE EL

    4 Pages

  18. NCE GS F

    4 Pages

  19. NCE ES

    4 Pages

  20. NCE PS

    4 Pages

  21. NCS3

    3 Pages

  22. NC3

    4 Pages

  23. NCD3

    3 Pages

  24. NCD

    8 Pages

  25. IDROMAT

    2 Pages

  26. EASYMAT

    4 Pages

  27. VARIOMAT

    2 Pages

  28. BS

    90 Pages

  29. AUE, AUD, AUED

    20 Pages

  30. QM, QT

    25 Pages

  31. N, N4

    26 Pages

  32. NM, NMD

    12 Pages